The safety and feasibility of minimally invasive plate osteosynthesis (MIPO) on the medial side of the femur: A cadaveric injection study

被引:46
|
作者
Jiamton, C. [1 ]
Apivatthakakul, T. [2 ,3 ]
机构
[1] Lerdsin Gen Hosp, Inst Orthopaed, Bangkok, Thailand
[2] Chiang Mai Univ, Fac Med, Dept Orthoped, Chiang Mai 50200, Thailand
[3] Chiang Mai Univ, Excellence Ctr, ORTC, Chiang Mai 50200, Thailand
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2015年 / 46卷 / 11期
关键词
Femoral fracture; Minimally invasive plate osteosynthesis (MIPO); Medial approach; Femoral artery; DISTAL FEMUR; INTERNAL-FIXATION; FEMORAL FRACTURES; OSTEOTOMY; IMPLANT;
D O I
10.1016/j.injury.2015.08.032
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Minimally invasive plate osteosynthesis (MIPO) on the medial side of the femur appears to be a dangerous procedure due to possible femoral artery injury. Objective: This study aims to determine the feasibility of applying MIPO of the femur via the medial approach, and to determine the anatomical relationship and structures at risk between the artery and the implant using computed tomography angiography. Materials and methods: A descriptive study of ten fresh cadavers was done. Two separate incisions were made, creating a submuscular tunnel close to the medial side of the femur. An 11- or 13-hole LCP lateral proximal tibial plate (5.0 mm) was inserted through the distal incision into the submuscular tunnel and fixed. A CT angiogram with 3D reconstruction was made to determine the distance from and location of the plate relative to the femoral artery and surgical dissection was done to identify the structures at risk. Results: No disruptions of superficial or deep femoral arteries were found. The closest distances from the superficial femoral artery and deep femoral artery to the plate were 8.3-27.2 mm (average 16.3 mm) (99% CI: 12.7-19.9) at the level 3 and 4.5-20.0 mm (average 8.6 mm) (99% CI: 6.4-10.9) at the level 2 in the proximal part of femur, respectively. The location where the SFA crossed the anterior cortex of the femur in the sagittal plane was 9.7-36.0% of the femoral length (average 20.1%) (99% CI: 15.0-25.3%) and the posterior cortex of the femur was 24.7-55.3% of the femoral length (average 40.8%) (99% CI: 35.0-46.7%). The location where the DFA crossed the anterior cortex of the femur in the sagittal plane was 7.9-25.3% of the femoral length (average 13.4%) (99% CI: 10.6-16.3%) and where it crossed the posterior cortex of the femur was 21.7-39.4% of the femoral length (average 31.2%) (99% CI: 27.1-33.3%). Conclusion: MIPO of the femur via medial approach is a feasible option for treatment of femoral fractures when the lateral approach is contraindicated. The distal 60% of the femoral length is safe for this approach. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2170 / 2176
页数:7
相关论文
共 50 条
  • [41] Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated
    T. Apivatthakakul
    S. Chiewcharntanakit
    International Orthopaedics, 2009, 33
  • [42] Minimally Invasive Plate Osteosynthesis (Mipo) With DCS In Subtrochanteric Femoral Fractures. Is Still A Reasonable Option?
    Dan, Sirbu Paul
    Razvan, Asaftei
    Tudor, Petreus
    Grigore, Berea
    Rares, Sova
    Razvan, Tudor
    2015 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2015,
  • [43] Outcomes of minimally invasive plate osteosynthesis (MIPO) with volar locking plates in distal radius fractures: A review
    Liverneaux, P.
    Ichihara, S.
    Facca, S.
    Diaz, J. J. Hidalgo
    HAND SURGERY & REHABILITATION, 2016, 35 : S80 - S85
  • [44] Minimally Invasive Plate Osteosynthesis (MIPO) for Periprosthetic Fracture After Total Ankle Arthroplasty: A Case Report
    Yang, Jae Hyuk
    Kim, Hak Jun
    Yoon, Jung-Ro
    Yoon, Yong-Cheol
    FOOT & ANKLE INTERNATIONAL, 2011, 32 (02) : 200 - 204
  • [45] Minimally invasive plate osteosynthesis without floating segment fixation for segmental fracture of femur
    Jitprapaikulsarn, Surasak
    Gromprasit, Arthit
    Patamamongkonchai, Chawanan
    Thremthakanpon, Witoon
    ACTA ORTHOPAEDICA BELGICA, 2021, 87 (04): : 629 - 634
  • [46] Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures
    Oh, Chang-Wug
    Kim, Jung-Jae
    Byun, Young-Soo
    Oh, Jong-Keon
    Kim, Joon-Woo
    Kim, Shin-Yoon
    Park, Byung-Chul
    Lee, Hyun-Joo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (12) : 1659 - 1665
  • [47] Evaluation of the Results of Minimally invasive Plate Osteosynthesis Using a Locking Plate in the Treatment of Distal Femur Fractures
    Abdelmonem, Abdelmonem H.
    Saber, Ahmed Y.
    El Sagheir, Mohamed
    El-Malky, Awad
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [48] Minimally invasive plate osteosynthesis (MIPO) for mid-shaft fracture of the tibia (AO/OTA classification 42): A retrospective study
    Kang, Hyunseong
    Song, Jung-Kook
    Rho, Joseph Y.
    Lee, Jaehwang
    Choi, Jaewon
    Choi, Sungwook
    ANNALS OF MEDICINE AND SURGERY, 2020, 60 : 408 - 412
  • [49] Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures
    Chang-Wug Oh
    Jung-Jae Kim
    Young-Soo Byun
    Jong-Keon Oh
    Joon-Woo Kim
    Shin-Yoon Kim
    Byung-Chul Park
    Hyun-Joo Lee
    Archives of Orthopaedic and Trauma Surgery, 2009, 129 : 1659 - 1665
  • [50] Minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: a cadaveric study and preliminary report
    Tanwar, Yashwant Singh
    Habib, Masood
    Jaiswal, Atin
    Singh, Satyaprakash
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (05) : 989 - 990