Effectiveness of sonography assisted minimal invasive plate osteosynthesis (MIPO) compare with fluoroscope assisted in femoral shaft fracture: A cadaveric study

被引:7
|
作者
Saengsin, Jirawat [1 ]
Vaseenon, Tanawat [1 ]
Pattamapaspong, Nuttaya [2 ]
Kritsaneephaiboon, Apipop [3 ]
机构
[1] Chiang Mai Univ, Fac Med, Dept Orthopaed, Chiang Mai, Thailand
[2] Chiang Mai Univ, Fac Med, Dept Radiol, Chiang Mai, Thailand
[3] Prince Songkla Univ, Fac Med, Dept Orthopaed, Hat Yai, Thailand
关键词
Ultrasound guidance; Sonography; Minimal invasive osteosynthesis; Plate; Radiation exposure; RADIATION-EXPOSURE; ULTRASOUND; PATIENT; PHYSICS;
D O I
10.1016/j.injury.2017.07.002
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: A minimal invasive plate osteosynthesis (MIPO) has an advantage of biological soft tissue preservation that consists of preserving bony blood supply, fracture hematoma and less soft tissue damage which leads to decreasing of infection rate and rapid bone healing. However, the radiation exposure is still a disadvantage of this technique. A sonography that provides dynamic real time imaging may be used as an alternative technique for assisting MIPO. The aim of this study was to compare the effectiveness of MIPO in femoral shaft fracture between the sonography assisted and the fluoroscopy assisted. Methods: Twenty-eight cadaveric limbs were subjected to create femoral shaft fracture. Then, sonography assisted reduction with temporary external fixation and MIPO were performed. Images of the sonography and the fluoroscopy were recorded including before reduction, after reduction and after MIPO in order to identify fracture displacements in anteroposterior and mediolateral directions. Moreover, the anterior and posterior distances from edge of the bone to the plate were measured to confirm plate position. The effectiveness of this technique was defined as the proper plate position and acceptable alignment after fixation. All distances from the sonography and the fluoroscopy were also analyzed and compared using Pearson correlation and Bland-Altman method to assess the agreements between two tests. Result: All of the subjects were met the criteria for acceptable alignment. We found only three femoral shaft fracture (11%) operated with MIPO by sonography assisted that showed slipped plate off femoral bones. According to Pearson correlation, there were good to excellent agreements in term of measuring fracture displacement before (Pearson Correlation > 0.7) and after reduction (Pearson Correlation > 0.7) between these two tests. There was moderate agreement regarding to evaluation of plate position (Pearson Correlation 03.-0.7). When we compared two methods of measurement using Bland-Altman plot, there were no statistical significant difference (P < 0.05). Conclusion: Images from the sonography could provide visualization of the fracture during reduction and MIPO as accurately as the radiography. Thus, the sonography assisted MIPO in femoral shaft fracture can be done effectively comparing with radiographic assisted. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1758 / 1763
页数:6
相关论文
共 50 条
  • [1] Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture - Is it possible? A cadaveric study and preliminary report
    Apivatthakakul, T
    Arpornchayanon, O
    Bavornratanavech, S
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (04): : 530 - 538
  • [2] Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated
    Apivatthakakul, T.
    Chiewcharntanakit, S.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (04) : 1119 - 1126
  • [3] Minimally invasive plate osteosynthesis (MIPO) in the treatment of the femoral shaft fracture where intramedullary nailing is not indicated
    T. Apivatthakakul
    S. Chiewcharntanakit
    International Orthopaedics, 2009, 33
  • [4] The Safety and Feasibility of Minimal Invasive Plate Osteosynthesis (MIPO) of the Posterior Aspect of the Humerus: A Cadaveric Study
    Jiamton, C.
    Ratreprasatsuk, N.
    Jarayabhand, R.
    Kritsaneephaiboon, A.
    Apivatthakakul, T.
    CLINICAL ANATOMY, 2019, 32 (02) : 176 - 182
  • [5] Minimally Invasive Plate Osteosynthesis (MIPO) technique for complex tibial shaft fracture
    Choi, Sungwook
    Lee, Tong Joo
    Kim, Shinil
    Cho, Changhee
    Shim, Seungjae
    Kang, Hyunseong
    ACTA ORTHOPAEDICA BELGICA, 2019, 85 (02): : 224 - 233
  • [6] Anteromedial minimally invasive plate osteosynthesis (MIPO) for distal third humeral shaft fractures - Is it possible?: A cadaveric study
    Buranaphatthana, T.
    Apivatthakakul, T.
    Apivatthakakul, V
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (06): : 1166 - 1174
  • [7] Danger zone for locking screw placement in minimally invasive plate osteosynthesis (MIPO) of humeral shaft fractures: A cadaveric study
    Apivatthakakul, T.
    Patiyasikan, S.
    Luevitoonvechkit, S.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (02): : 169 - 172
  • [8] Minimally Invasive Plate Osteosynthesis (MIPO) Through the Posterior Approach for the Humerus: A Cadaveric Study
    Singh, Adhish P.
    Chauhan, Vijendra D.
    Kumar, Sanad
    Singh, Deepa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [9] Minimal invasive plate osteosynthesis (MIPO) of clavicle fracture with locking plate (LCP)-10 years experience
    Mueller, T. S.
    Sommer, C.
    BRITISH JOURNAL OF SURGERY, 2012, 99 : 16 - 16
  • [10] Minimally Invasive Plate Osteosynthesis (MIPO) for Treatment of Delayed or Nonunion of the Humerus Shaft Fracture: A New Technique
    Okhovatpour, Mohammad Ali
    Yousefi-Hajivand, Esmaeel
    Khojasteh, Arash
    Tabrizi, Ali
    Mirahmadi, Alireza
    TRAUMA MONTHLY, 2022, 27 (02) : 445 - 452