Effectiveness of sonography assisted minimal invasive plate osteosynthesis (MIPO) compare with fluoroscope assisted in femoral shaft fracture: A cadaveric study

被引:7
|
作者
Saengsin, Jirawat [1 ]
Vaseenon, Tanawat [1 ]
Pattamapaspong, Nuttaya [2 ]
Kritsaneephaiboon, Apipop [3 ]
机构
[1] Chiang Mai Univ, Fac Med, Dept Orthopaed, Chiang Mai, Thailand
[2] Chiang Mai Univ, Fac Med, Dept Radiol, Chiang Mai, Thailand
[3] Prince Songkla Univ, Fac Med, Dept Orthopaed, Hat Yai, Thailand
关键词
Ultrasound guidance; Sonography; Minimal invasive osteosynthesis; Plate; Radiation exposure; RADIATION-EXPOSURE; ULTRASOUND; PATIENT; PHYSICS;
D O I
10.1016/j.injury.2017.07.002
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: A minimal invasive plate osteosynthesis (MIPO) has an advantage of biological soft tissue preservation that consists of preserving bony blood supply, fracture hematoma and less soft tissue damage which leads to decreasing of infection rate and rapid bone healing. However, the radiation exposure is still a disadvantage of this technique. A sonography that provides dynamic real time imaging may be used as an alternative technique for assisting MIPO. The aim of this study was to compare the effectiveness of MIPO in femoral shaft fracture between the sonography assisted and the fluoroscopy assisted. Methods: Twenty-eight cadaveric limbs were subjected to create femoral shaft fracture. Then, sonography assisted reduction with temporary external fixation and MIPO were performed. Images of the sonography and the fluoroscopy were recorded including before reduction, after reduction and after MIPO in order to identify fracture displacements in anteroposterior and mediolateral directions. Moreover, the anterior and posterior distances from edge of the bone to the plate were measured to confirm plate position. The effectiveness of this technique was defined as the proper plate position and acceptable alignment after fixation. All distances from the sonography and the fluoroscopy were also analyzed and compared using Pearson correlation and Bland-Altman method to assess the agreements between two tests. Result: All of the subjects were met the criteria for acceptable alignment. We found only three femoral shaft fracture (11%) operated with MIPO by sonography assisted that showed slipped plate off femoral bones. According to Pearson correlation, there were good to excellent agreements in term of measuring fracture displacement before (Pearson Correlation > 0.7) and after reduction (Pearson Correlation > 0.7) between these two tests. There was moderate agreement regarding to evaluation of plate position (Pearson Correlation 03.-0.7). When we compared two methods of measurement using Bland-Altman plot, there were no statistical significant difference (P < 0.05). Conclusion: Images from the sonography could provide visualization of the fracture during reduction and MIPO as accurately as the radiography. Thus, the sonography assisted MIPO in femoral shaft fracture can be done effectively comparing with radiographic assisted. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1758 / 1763
页数:6
相关论文
共 50 条
  • [21] Danger zone for screw placement in minimally invasive plate osteosynthesis (MIPO) of diaphyseal fractures of forearm: a cadaveric study
    Kritsaneephaiboon, Apipop
    Wuttimanop, Watit
    Jitprapaikulsarn, Surasak
    Dissaneewate, Pornpanit
    Chewakidakarn, Chulin
    Orapiriyakul, Wich
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (08) : 2111 - 2119
  • [22] Minimal invasive plate osteosynthesis for the dislocated humeral head fracture associated with ipsilateral humeral shaft fracture: A case report
    Nhat Pham Van
    Hieu Nguyen
    Tuan Nguyen Anh
    Xuan Tran Chanh
    ORTHOPEDIC REVIEWS, 2023, 15
  • [23] Arthroscopically assisted minimally invasive plate osteosynthesis for posterior fracture-dislocation of the shoulder
    Fukuda, Aki
    Nishimura, Akinobu
    Kato, Ko
    Sudo, Akihiro
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2014, 19 (01) : 194 - 197
  • [24] Using a Traction Table for Fracture Reduction during Minimally Invasive Plate Osteosynthesis (MIPO) of Distal Femoral Fractures Provides Anatomical Alignment
    Paulsson, Martin
    Ekholm, Carl
    Tranberg, Roy
    Rolfson, Ola
    Geijer, Mats
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (12)
  • [25] A Dual-Mode Robot-Assisted Plate Implantation Method for Femoral Shaft Fracture
    Guo, Yanchao
    Chen, Yimiao
    Zhou, Xianzheng
    Bi, Jianping
    Moore, Jason Z.
    Zhang, Qinhe
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2024, 20 (06):
  • [26] Functional outcomes of minimal invasive percutaneous plate osteosynthesis (MIPPO) in humerus shaft fractures: a clinical study
    Huri, Gazi
    Bicer, Omer Sunar
    Ozturk, Hakan
    Deveci, Mehmet Ali
    Tan, Ismet
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (04) : 406 - 412
  • [27] Comparison of minimally invasive plate osteosynthesis (MIPO) and open reduction and internal fixation (ORIF) for the treatment of radial shaft fractures: a retrospective study
    Hyun-Tak Kang
    Yang-Hoon Jo
    Hong-Je Kang
    BMC Musculoskeletal Disorders, 26 (1)
  • [28] Preliminary Study in a Novel Robotic-Assisted Femoral Shaft Fracture Reduction System
    Zhu, Qing
    Wang, Xingsong
    Sun, Xiaogang
    Liang, Bin
    ROBOT INTELLIGENCE TECHNOLOGY AND APPLICATIONS 4, 2017, 447 : 289 - 298
  • [29] Minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: a cadaveric study and preliminary report
    Yashwant Singh Tanwar
    Masood Habib
    Atin Jaiswal
    Satyaprakash Singh
    International Orthopaedics, 2013, 37 : 989 - 990
  • [30] Minimally invasive plate osteosynthesis of distal tibial fracture using a posterolateral approach: a cadaveric study and preliminary report
    Tanwar, Yashwant Singh
    Habib, Masood
    Jaiswal, Atin
    Singh, Satyaprakash
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (05) : 989 - 990