Experimental study of a new tracheal prosthesis: Pored Dacron tube

被引:31
|
作者
Tsukada, H [1 ]
Osada, H [1 ]
机构
[1] St Marianna Univ, Sch Med, Dept Surg, Div Chest Surg,Miyamae Ku, Kawasaki, Kanagawa, Japan
来源
关键词
D O I
10.1016/S0022-5223(03)01317-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study was designed to evaluate how various sizes and densities of pores in Dacron tubing might enhance its utility as a tracheal prosthesis. Methods: A vascular prosthesis made of knitted external velour polyester was prepared for pore formation with a laser. The first set compared different pore sizes (300, 500, and 700 mum) and pore densities (25/cm(2) or 100/cm(2)). Grafts were reinforced with an externally heat-sealed silicone ring. The second set tested grafts with a pore density of 64/cm(2) and a pore size of 500 mum internally reinforced with a stainless-steel spiral stent. In all experiments, a canine mediastinal trachea 10 cartilage rings in length was resected, and the prosthesis was then implanted with an omental flap. Results: Lower pore size and density (300 mum, 25 pores/cm(2)) led to essentially no tissue ingrowth. Larger pore size (700 mum) and low density (25 pores/cm(2)) led to rapid and excessive ingrowth of granulation. Midrange pore size (500 mum) and high density (100 pores/cm(2)) invited steady tissue ingrowth, but marked luminal stenosis eventually developed. Stent-reinforced prostheses with 500-mum pores at 64 pores/cm(2), as used in the second set, maintained an average patency rate of 60% or more (range, 20%-100%) at least 12 months after implantation. Conclusion: Our data show that porosity is a key factor for tissue growth through our Dacron tracheal prostheses. This artificial trachea model has led to long-term survivors up to 27 months after the operation and seems promising as a basic model for clinical tracheal repair.
引用
收藏
页码:877 / 884
页数:8
相关论文
共 50 条
  • [21] HEALING OF A NEW MICROPOROUS TRACHEAL PROSTHESIS
    HOLWICK, JL
    KLEIN, SR
    SPROAT, RW
    MIRANDA, RM
    HIROSE, FM
    WHITE, RA
    NELSON, RJ
    SURGICAL FORUM, 1980, 31 : 541 - 543
  • [23] Replacement of a tracheal segment by a mixed graft (aorta and prosthesis): an experimental study in rabbits
    Feito, BA
    Rath, AM
    Kambouchner, M
    Tremblay, B
    Eugene, M
    Marchix, T
    Djenandar, F
    Soilleux, M
    Chevrel, JP
    EUROPEAN JOURNAL OF SURGERY, 1999, 165 (12) : 1175 - 1181
  • [24] A new laser tracheal tube
    Ungemach, J
    Foth, HJ
    Hormann, K
    Preponis, E
    LASERS IN MEDICINE AND DENTISTRY: DIAGNOSTICS AND TREATMENT, 1996, 2887 : 129 - 132
  • [25] STUDY ON COMPLEX MATERIAL FOR TRACHEAL PROSTHESIS
    Qi Liangchen
    Wang Fuzhong. Liu Demo(Department of Thoracic Surgery
    Third Teaching Hospital.)
    白求恩医科大学学报, 1992, (02) : 152 - 155
  • [26] Tracheal airway pressure in tracheostomy tube capping trials: an experimental study
    Nowak, Andreas
    Martin, Sten
    Hoehne, Maik
    Heller, Winfried
    Usichenko, Taras, I
    Klemm, Eckart
    BMC PULMONARY MEDICINE, 2022, 22 (01)
  • [27] SEM STUDY OF PRECLOTTING INTO DACRON POLYESTER FIBER FOR VASCULAR PROSTHESIS
    GUIDOIN, RG
    GOSSELIN, C
    AWAD, JA
    ROULEAU, C
    HAGGIS, GH
    TURCOT, J
    UNION MEDICALE DU CANADA, 1974, 103 (08): : 1374 - 1381
  • [28] Tracheal airway pressure in tracheostomy tube capping trials: an experimental study
    Andreas Nowak
    Sten Martin
    Maik Höhne
    Winfried Heller
    Taras I. Usichenko
    Eckart Klemm
    BMC Pulmonary Medicine, 22
  • [29] Retrograde nasotracheal intubation with a new tracheal tube:: a feasibility study
    Agrò, F
    Brimacombe, J
    Doyle, DJ
    Marchionni, L
    Cataldo, R
    BRITISH JOURNAL OF ANAESTHESIA, 2000, 84 (02) : 257 - 259
  • [30] Experimental reconstruction of tracheal defect with siliconcarbofiber prosthesis in dogs
    Zhen-he, Z.
    Chinese Journal of Biomedical Engineering, 1988, 7 (04) : 196 - 198