Experimental study of a new tracheal prosthesis: Pored Dacron tube

被引:31
|
作者
Tsukada, H [1 ]
Osada, H [1 ]
机构
[1] St Marianna Univ, Sch Med, Dept Surg, Div Chest Surg,Miyamae Ku, Kawasaki, Kanagawa, Japan
来源
关键词
D O I
10.1016/S0022-5223(03)01317-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study was designed to evaluate how various sizes and densities of pores in Dacron tubing might enhance its utility as a tracheal prosthesis. Methods: A vascular prosthesis made of knitted external velour polyester was prepared for pore formation with a laser. The first set compared different pore sizes (300, 500, and 700 mum) and pore densities (25/cm(2) or 100/cm(2)). Grafts were reinforced with an externally heat-sealed silicone ring. The second set tested grafts with a pore density of 64/cm(2) and a pore size of 500 mum internally reinforced with a stainless-steel spiral stent. In all experiments, a canine mediastinal trachea 10 cartilage rings in length was resected, and the prosthesis was then implanted with an omental flap. Results: Lower pore size and density (300 mum, 25 pores/cm(2)) led to essentially no tissue ingrowth. Larger pore size (700 mum) and low density (25 pores/cm(2)) led to rapid and excessive ingrowth of granulation. Midrange pore size (500 mum) and high density (100 pores/cm(2)) invited steady tissue ingrowth, but marked luminal stenosis eventually developed. Stent-reinforced prostheses with 500-mum pores at 64 pores/cm(2), as used in the second set, maintained an average patency rate of 60% or more (range, 20%-100%) at least 12 months after implantation. Conclusion: Our data show that porosity is a key factor for tissue growth through our Dacron tracheal prostheses. This artificial trachea model has led to long-term survivors up to 27 months after the operation and seems promising as a basic model for clinical tracheal repair.
引用
收藏
页码:877 / 884
页数:8
相关论文
共 50 条
  • [41] REDUCTION OF TRACHEAL TUBE TIP DAMAGE USING A NEW TUBE
    MACKENZIE, CF
    MCDOWELL, EM
    HELRICH, M
    CRITICAL CARE MEDICINE, 1984, 12 (03) : 259 - 259
  • [42] DACRON TUBE AND BIFURCATION ARTERIAL PROSTHESES PRODUCED TO SPECIFICATION - EXPERIMENTAL AND CLINICAL USE
    JULIAN, OC
    DETERLING, RA
    SU, HH
    DYE, WS
    BELIO, ML
    SURGERY, 1957, 41 (01) : 50 - 61
  • [43] Experimental study on hydrodynamic effect of orientation micro-pored surfaces
    ShaoXian Bai
    XuDong Peng
    JiYun Li
    XiangKai Meng
    Science China Technological Sciences, 2011, 54 : 659 - 662
  • [44] New formulae for predicting tracheal tube length
    Lau, Nicky
    Playfor, Stephen D.
    Rashid, Asrar
    Dhanarass, Muthu
    PEDIATRIC ANESTHESIA, 2006, 16 (12) : 1238 - 1243
  • [45] Difficult tracheal tube insertion: A new phraseology
    Abratt, Raymond P.
    SAMJ SOUTH AFRICAN MEDICAL JOURNAL, 2016, 106 (02):
  • [46] A new type of polytetrafluoroethylene prosthesis (Mycro Mesh): An experimental study
    Bellon, JM
    Contreras, LA
    Bujan, J
    Martin, AC
    JorgeHerrero, E
    Campo, C
    Hernando, A
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1996, 7 (08) : 475 - 478
  • [47] RECONSTRUCTION OF CIRCUMFERENTIAL TRACHEAL DEFECTS WITH A POROUS PROSTHESIS - AN EXPERIMENTAL CLINICAL STUDY USING HEAVY MARLEX MESH
    PEARSON, FG
    HENDERSO.RD
    GROSS, AE
    GINSBERG, RJ
    STONE, RM
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1968, 55 (05): : 605 - &
  • [48] CLINICAL NOTES NEW INSTRUMENTS AND TECHNIQUES - TRACHEAL PROSTHESIS FOR STENOSIS
    CONLEY, JJ
    ARCHIVES OF OTOLARYNGOLOGY, 1965, 82 (04): : 433 - &
  • [49] Experimental study on hydrodynamic effect of orientation micro-pored surfaces
    BAI ShaoXian1
    2Key Laboratory of Special Purpose Equipment and Advanced Processing Technology
    Science China(Technological Sciences), 2011, (03) : 659 - 662
  • [50] Experimental study on hydrodynamic effect of orientation micro-pored surfaces
    Bai ShaoXian
    Peng XuDong
    Li JiYun
    Meng XiangKai
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2011, 54 (03) : 659 - 662