Experimental study of a new tracheal prosthesis: Pored Dacron tube

被引:31
|
作者
Tsukada, H [1 ]
Osada, H [1 ]
机构
[1] St Marianna Univ, Sch Med, Dept Surg, Div Chest Surg,Miyamae Ku, Kawasaki, Kanagawa, Japan
来源
关键词
D O I
10.1016/S0022-5223(03)01317-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study was designed to evaluate how various sizes and densities of pores in Dacron tubing might enhance its utility as a tracheal prosthesis. Methods: A vascular prosthesis made of knitted external velour polyester was prepared for pore formation with a laser. The first set compared different pore sizes (300, 500, and 700 mum) and pore densities (25/cm(2) or 100/cm(2)). Grafts were reinforced with an externally heat-sealed silicone ring. The second set tested grafts with a pore density of 64/cm(2) and a pore size of 500 mum internally reinforced with a stainless-steel spiral stent. In all experiments, a canine mediastinal trachea 10 cartilage rings in length was resected, and the prosthesis was then implanted with an omental flap. Results: Lower pore size and density (300 mum, 25 pores/cm(2)) led to essentially no tissue ingrowth. Larger pore size (700 mum) and low density (25 pores/cm(2)) led to rapid and excessive ingrowth of granulation. Midrange pore size (500 mum) and high density (100 pores/cm(2)) invited steady tissue ingrowth, but marked luminal stenosis eventually developed. Stent-reinforced prostheses with 500-mum pores at 64 pores/cm(2), as used in the second set, maintained an average patency rate of 60% or more (range, 20%-100%) at least 12 months after implantation. Conclusion: Our data show that porosity is a key factor for tissue growth through our Dacron tracheal prostheses. This artificial trachea model has led to long-term survivors up to 27 months after the operation and seems promising as a basic model for clinical tracheal repair.
引用
收藏
页码:877 / 884
页数:8
相关论文
共 50 条
  • [31] EXPERIMENTAL TRACHEAL TUBE CREATED WITH VASCULARIZED FASCIA
    DELAERE, PR
    LIU, ZY
    FEENSTRA, L
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1993, 102 (12): : 935 - 940
  • [32] A new, improved tracheal tube connector
    Liban, JB
    ANAESTHESIA, 1998, 53 (06) : 606 - 606
  • [33] A NEW UNIVERSAL TRACHEAL TUBE FIXATOR
    HAGELSTE.JO
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1964, S : 161 - &
  • [34] A new tracheal tube for difficult intubation
    West, MRJ
    Jonas, MM
    Adams, AP
    Carli, F
    BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 (05) : 673 - 679
  • [35] Design and study of carbon fiber tracheal prosthesis
    Qi, Liangchen
    Liu, Deruo
    Han, Zhenguo
    Wang, Fuzhong
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 1998, 15 (04): : 328 - 334
  • [36] PATHOGENESIS OF TRACHEAL STENOSIS FOLLOWING TRACHEOSTOMY WITH A CUFFED TUBE - EXPERIMENTAL STUDY IN DOGS
    GOLDBERG, M
    PEARSON, FG
    THORAX, 1972, 27 (06) : 678 - &
  • [37] PRECLOTTING OF KNITTED DACRON PROSTHESIS - SCANNING ELECTRON-MICROSCOPE STUDY
    GUIDOIN, RG
    GOSSELIN, C
    ROULEAU, C
    HAGGIS, GH
    BOULAY, J
    AWAD, J
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1975, 70 (01): : 152 - 162
  • [38] PRECLOTTING AND THROMBOSIS OF A DACRON PROSTHESIS - SCANNING ELECTRON-MICROSCOPE STUDY
    GUIDOIN, RG
    AWAD, JA
    GOSSELIN, C
    ROULEAU, C
    HAGGIS, GH
    BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1975, 3 (03): : 365 - 382
  • [39] A new porous tracheal prosthesis sealed with collagen sponge
    TERAMACHI, M
    KIYOTANI, T
    TAKIMOTO, Y
    NAKAMURA, T
    SHIMIZU, Y
    ASAIO JOURNAL, 1995, 41 (03) : M306 - M310
  • [40] EXPERIMENTAL-STUDY OF TRACHEAL PROSTHESIS - ANALYSIS OF THE FINDINGS FROM LONG-TERM SURVIVAL
    MAEDA, T
    KUBO, Y
    NAKAJIMA, S
    HAYASHI, H
    SAMEJIMA, N
    TAKEUCHI, K
    ARTIFICIAL ORGANS, 1988, 12 (05) : 454 - 454