Retrograde nasotracheal intubation with a new tracheal tube:: a feasibility study

被引:5
|
作者
Agrò, F
Brimacombe, J [1 ]
Doyle, DJ
Marchionni, L
Cataldo, R
机构
[1] Univ Queensland, Dept Anaesthesia & Intens Care, Cairns Base Hosp, Cairns, Qld 4870, Australia
[2] Univ Toronto, Dept Anaesthesia, Toronto, ON, Canada
[3] Toronto Hosp, Toronto, ON M5T 2S8, Canada
[4] Univ Rome, Sch Med, Dept Anaesthesia, I-00100 Rome, Italy
关键词
equipment; Foley catheter; tubes tracheal; intubation nasotracheal; technique; surgery; oropharyngeal;
D O I
10.1093/oxfordjournals.bja.a013415
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We have assessed the feasibility of retrograde nasotracheal intubation using a flexometallic tracheal tube with a detachable pilot balloon and connector in a study of 20 consecutive adult patients undergoing oropharyngeal surgery. The technique consisted of: (I) laryngoscope-guided orotracheal intubation; (2) insertion of an 18-gauge Foley catheter through the nose and retraction into the mouth; (3) detachment of the anaesthesia circuit, pilot balloon and connector; (4) insertion of the Foley catheter tip into the proximal end of the tracheal tube and inflation of the Foley catheter cuff; (5) withdrawal of the Foley catheter and attached tracheal tube back through the nose; (6) deflation of the Foley catheter cuff; and (7) re-attachment of the pilot balloon, connector and anaesthesia circuit. The technique was successful at the first attempt in all patients. Mean time taken to insert the Foley catheter and retract it into the mouth was 19 (range 12-30) s. Mean time taken from disconnection to reconnection of the anaesthesia circuit was 8 (6-10) s. Heart rate increased after intubation, but there were no significant changes in arterial pressure. Nasal bleeding, airway problems and hypoxic events did not occur. No anatomical abnormalities or nasal trauma were detected at rhinoscopy. We conclude that retrograde nasotracheal intubation is feasible using a flexometallic tracheal tube with a detachable pilot balloon and connector.
引用
收藏
页码:257 / 259
页数:3
相关论文
共 50 条
  • [1] TRACHEAL TUBE GUIDE TO FACILITATE NASOTRACHEAL INTUBATION
    CHESTER, MH
    [J]. ANESTHESIOLOGY, 1984, 60 (05) : 522 - 523
  • [2] The Intavent® tracheal tube in nasotracheal fibreoptic intubation
    Barker, KF
    Bolton, P
    Cole, S
    Coe, PA
    [J]. ANAESTHESIA, 2001, 56 (02) : 189 - 190
  • [3] Tracheal tube impingement during nasotracheal fibreoptic intubation
    Marfin, A. G.
    Pandit, J. J.
    Dombrovskis, A.
    Popat, M. T.
    Mihm, F.
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 62 - 63
  • [4] Tracheal tube impingement during nasotracheal fibreoptic intubation
    Marfin, AG
    Pandit, JJ
    Dombrovskis, A
    Popat, MT
    Mihm, F
    [J]. ANAESTHESIA, 2004, 59 (10) : 1043 - 1043
  • [5] INFLATION OF THE TRACHEAL TUBE CUFF AS AN AID TO BLIND NASOTRACHEAL INTUBATION
    CAVDARSKI, A
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 (01) : 139 - 140
  • [6] Nasotracheal intubation using the Airway Scope and an Endotrol tracheal tube
    Imashuku, Y.
    Kura, M.
    Sukenaga, C.
    Otada, H.
    Kitagawa, H.
    [J]. ANAESTHESIA, 2011, 66 (05) : 399 - 399
  • [7] TRACHEAL TUBE CUFF INFLATION AS AN AID TO BLIND NASOTRACHEAL INTUBATION
    VANELSTRAETE, AC
    PENNANT, JH
    GAJRAJ, NM
    VICTORY, RA
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1993, 70 (06) : 691 - 693
  • [8] Another cause of damage to tracheal tube cuff during nasotracheal intubation
    Mahajan, Rajesh
    Nazir, Robina
    Gulati, Smriti
    Rasool, Ashufta
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2016, 31 : 111 - 112
  • [9] Determination of the site of tracheal tube impingement during nasotracheal fibreoptic intubation
    Marfin, A. G.
    Iqbal, R.
    Mihm, F.
    Popat, M. T.
    Scott, S. H.
    Pandit, J. J.
    [J]. ANAESTHESIA, 2006, 61 (07) : 646 - 650
  • [10] A NEW PARTIAL SPIRAL TUBE FOR NASOTRACHEAL INTUBATION
    HATANO, Y
    ARAI, T
    HARIOKA, T
    [J]. ANESTHESIOLOGY, 1985, 62 (02) : 209 - 209