Newly Designed Amperometric Biosensor for Hydrogen Peroxide and Glucose Based on Vanadium Sulfide Nanoparticles

被引:47
|
作者
Sarkar, Arpita [1 ]
Ghosh, Abhisek Brata [1 ]
Saha, Namrata [1 ]
Bhadu, Gopala Ram [2 ]
Adhikary, Bibhutosh [1 ]
机构
[1] Indian Inst Engn Sci & Technol, Dept Chem, Howrah 711103, W Bengal, India
[2] Cent Salt & Marine Chem Res Inst, Dept Analyt Sci, Gijubhai Badheka Marg, Bhavnagar 364002, Gujarat, India
来源
ACS APPLIED NANO MATERIALS | 2018年 / 1卷 / 03期
关键词
VS2; NPs; fabrication; modified electrode; biosensing; amperometric biosensor; DIRECT ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL SENSING PLATFORM; REDUCED GRAPHENE OXIDE; NONENZYMATIC DETECTION; GOLD NANOPARTICLES; FLUORESCENT-PROBE; CARBON; SENSOR; ELECTRODE; REDUCTION;
D O I
10.1021/acsanm.8b00076
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In the present work, we describe a facile, green, and template-free solvothermal fabrication of vanadium sulfide (VS2) nanoparticles (NPs) and their application for the electrochemical detection of hydrogen peroxide (H2O2) and glucose. The morphology and composition of as-prepared samples were well-characterized by powder X-ray diffraction, energy-dispersive spectroscopy, transmission electron microscopy, scanning electron microscopy, UV-vis spectroscopy, and Brunauer-Emmett-Teller surface area measurement. Because of their interesting electrochemical responses toward H2O2, a novel nonenzymatic electrochemical sensor for H2O2 and glucose detection has been proposed based on a VS2 NP-modified glassy carbon electrode. The modified electrode showed an excellent electrochemical performance for the selective and sensitive nonenzymatic detection of H2O2 in a broad concentration range of 0.5 mu M to 3.0 mM, with a wide linear range of 0.5 mu M to 2.5 mM and a lower detection limit of 0.224 mu M. The newly developed sensor also displayed high sensitivity (41.96 mu A mM(-1)) toward the detection of glucose with a broad linear range of 0.5 mu M to 3 mM. The as-fabricated sensor also showed very high sensitivity, excellent reusability, long-term stability, and negligible interference ability. Moreover, the synthesized NPs were applied for H2O2 and glucose detection in real samples, signifying their potential application in routine H2O2 and glucose analysis. The present study reveals that as-prepared VS2 NPs are promising for electrochemical H2O2 and glucose sensing and other biological applications.
引用
收藏
页码:1339 / 1347
页数:17
相关论文
共 50 条
  • [41] Functionalized Palladium Nanoparticles for Hydrogen Peroxide Biosensor
    Baccar, H.
    Ktari, T.
    Abdelghani, A.
    INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY, 2011, 2011
  • [42] Flow-injection determination of trace hydrogen peroxide or glucose utilizing an amperometric biosensor based on glucose oxidase bound to a reticulated vitreous carbon electrode
    Khayyami, M
    Johansson, G
    Kriz, D
    Xie, B
    Larsson, PO
    Danielsson, B
    TALANTA, 1996, 43 (06) : 957 - 962
  • [43] Peroxidase-like behavior, amperometric biosensing of hydrogen peroxide and photocatalytic activity by cadmium sulfide nanoparticles
    Maji, Swarup Kumar
    Dutta, Amit Kumar
    Srivastava, Divesh N.
    Paul, Parimal
    Mondal, Anup
    Adhikary, Bibhutosh
    JOURNAL OF MOLECULAR CATALYSIS A-CHEMICAL, 2012, 358 : 1 - 9
  • [44] Hydrogen Peroxide Biosensor Based on Carbon Supported Ultrafine Silver Nanoparticles
    Wang Yi-Chen
    Jiang Xiu-E
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (05) : 689 - 694
  • [45] Hydrogen peroxide biosensor based on immobilizing enzyme by gold nanoparticles and thionine
    Chen Xian-Guang
    Qian Ying
    Zhang Su-Juan
    Zou Xiao-Yong
    ACTA CHIMICA SINICA, 2007, 65 (04) : 337 - 343
  • [46] An amperometric glucose biosensor based on PEDOT nanofibers
    Cetin, Merih Zeynep
    Camurlu, Pinar
    RSC ADVANCES, 2018, 8 (35): : 19724 - 19731
  • [47] Amperometric glucose biosensor based on electroconductive hydrogels
    Kotanen, Christian N.
    Tlili, Chaker
    Guiseppi-Elie, Anthony
    TALANTA, 2013, 103 : 228 - 235
  • [48] Amperometric glucose biosensor based on lipid film
    Wu, ZY
    Wang, BQ
    Dong, SJ
    Wang, EK
    BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4): : 143 - 147
  • [49] Amperometric enzyme biosensor for hydrogen peroxide via Ugi multicomponent reaction
    Camacho, Conrado
    Matias, Juan C.
    Garcia, Daniel
    Simpson, Benjamin K.
    Villalonga, Reynaldo
    ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (07) : 1655 - 1660
  • [50] Amperometric study of hydrogen peroxide biosensor with butadiene rubber as immobilization matrix
    Lee, Beom-Gyu
    Rhyu, Keun-Bae
    Yoon, Kil-Joong
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2010, 16 (03) : 340 - 343