Newly Designed Amperometric Biosensor for Hydrogen Peroxide and Glucose Based on Vanadium Sulfide Nanoparticles

被引:47
|
作者
Sarkar, Arpita [1 ]
Ghosh, Abhisek Brata [1 ]
Saha, Namrata [1 ]
Bhadu, Gopala Ram [2 ]
Adhikary, Bibhutosh [1 ]
机构
[1] Indian Inst Engn Sci & Technol, Dept Chem, Howrah 711103, W Bengal, India
[2] Cent Salt & Marine Chem Res Inst, Dept Analyt Sci, Gijubhai Badheka Marg, Bhavnagar 364002, Gujarat, India
来源
ACS APPLIED NANO MATERIALS | 2018年 / 1卷 / 03期
关键词
VS2; NPs; fabrication; modified electrode; biosensing; amperometric biosensor; DIRECT ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL SENSING PLATFORM; REDUCED GRAPHENE OXIDE; NONENZYMATIC DETECTION; GOLD NANOPARTICLES; FLUORESCENT-PROBE; CARBON; SENSOR; ELECTRODE; REDUCTION;
D O I
10.1021/acsanm.8b00076
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In the present work, we describe a facile, green, and template-free solvothermal fabrication of vanadium sulfide (VS2) nanoparticles (NPs) and their application for the electrochemical detection of hydrogen peroxide (H2O2) and glucose. The morphology and composition of as-prepared samples were well-characterized by powder X-ray diffraction, energy-dispersive spectroscopy, transmission electron microscopy, scanning electron microscopy, UV-vis spectroscopy, and Brunauer-Emmett-Teller surface area measurement. Because of their interesting electrochemical responses toward H2O2, a novel nonenzymatic electrochemical sensor for H2O2 and glucose detection has been proposed based on a VS2 NP-modified glassy carbon electrode. The modified electrode showed an excellent electrochemical performance for the selective and sensitive nonenzymatic detection of H2O2 in a broad concentration range of 0.5 mu M to 3.0 mM, with a wide linear range of 0.5 mu M to 2.5 mM and a lower detection limit of 0.224 mu M. The newly developed sensor also displayed high sensitivity (41.96 mu A mM(-1)) toward the detection of glucose with a broad linear range of 0.5 mu M to 3 mM. The as-fabricated sensor also showed very high sensitivity, excellent reusability, long-term stability, and negligible interference ability. Moreover, the synthesized NPs were applied for H2O2 and glucose detection in real samples, signifying their potential application in routine H2O2 and glucose analysis. The present study reveals that as-prepared VS2 NPs are promising for electrochemical H2O2 and glucose sensing and other biological applications.
引用
收藏
页码:1339 / 1347
页数:17
相关论文
共 50 条
  • [11] A Review on Glucose and Hydrogen Peroxide Biosensor Based on Modified Electrode Included Silver Nanoparticles
    Rad, Ali Shokuhi
    Mirabi, Ali
    Binaian, Ehsan
    Tayebi, Habibollah
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (08): : 3671 - 3683
  • [12] A mediated turnip tissue-based amperometric hydrogen peroxide biosensor
    Chut, SL
    Li, J
    Tan, SN
    ANALYTICAL LETTERS, 1997, 30 (11) : 1993 - 1998
  • [13] Amperometric hydrogen peroxide biosensor based on covalently immobilizing thionine as a mediator
    Ma, Liping
    Yuan, Ruo
    Chai, Yaqin
    Chen, Shihong
    Ling, Shujuan
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2009, 32 (04) : 537 - 544
  • [14] KOHLRABI-BASED AMPEROMETRIC BIOSENSOR FOR HYDROGEN-PEROXIDE MEASUREMENT
    CHEN, L
    LIN, MS
    HARA, M
    RECHNITZ, GA
    ANALYTICAL LETTERS, 1991, 24 (01) : 1 - 14
  • [15] Amperometric hydrogen peroxide biosensor based on covalently immobilizing thionine as a mediator
    Liping Ma
    Ruo Yuan
    Yaqin Chai
    Shihong Chen
    Shujuan Ling
    Bioprocess and Biosystems Engineering, 2009, 32 : 537 - 544
  • [16] Amperometric biosensor for hydrogen peroxide based on immobilisation of haemoglobin on mesoporous zirconia
    Liu, Changhua
    Teng, Yingli
    Xu, Jing
    Yang, Yajuan
    Wu, Zongfang
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2011, 91 (14) : 1367 - 1379
  • [17] Amperometric biosensor for hydrogen peroxide based on horseradish peroxidase onto gold nanowires and TiO2 nanoparticles
    Huaan Zhong
    Ruo Yuan
    Yaqin Chai
    Wenjuan Li
    Yu Zhang
    Chengyan Wang
    Bioprocess and Biosystems Engineering, 2011, 34
  • [18] A novel amperometric biosensor for determination of hydrogen peroxide based on nafion and polythionine as well as gold nanoparticles and gelatin as matrixes
    Zhu, Q
    Yuan, R
    Chai, YQ
    Zhuo, Y
    Zhang, Y
    Li, XL
    Wang, N
    ANALYTICAL LETTERS, 2006, 39 (03) : 483 - 494
  • [19] Amperometric biosensor for hydrogen peroxide based on horseradish peroxidase onto gold nanowires and TiO2 nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Li, Wenjuan
    Zhang, Yu
    Wang, Chengyan
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2011, 34 (08) : 923 - 930
  • [20] Amperometric hydrogen peroxide biosensor based on cobalt ferrite-chitosan nanocomposite
    Yardimci, Feyza S.
    Senel, Mehmet
    Baykal, Abdulhadi
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (02): : 269 - 275