Newly Designed Amperometric Biosensor for Hydrogen Peroxide and Glucose Based on Vanadium Sulfide Nanoparticles

被引:47
|
作者
Sarkar, Arpita [1 ]
Ghosh, Abhisek Brata [1 ]
Saha, Namrata [1 ]
Bhadu, Gopala Ram [2 ]
Adhikary, Bibhutosh [1 ]
机构
[1] Indian Inst Engn Sci & Technol, Dept Chem, Howrah 711103, W Bengal, India
[2] Cent Salt & Marine Chem Res Inst, Dept Analyt Sci, Gijubhai Badheka Marg, Bhavnagar 364002, Gujarat, India
来源
ACS APPLIED NANO MATERIALS | 2018年 / 1卷 / 03期
关键词
VS2; NPs; fabrication; modified electrode; biosensing; amperometric biosensor; DIRECT ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL SENSING PLATFORM; REDUCED GRAPHENE OXIDE; NONENZYMATIC DETECTION; GOLD NANOPARTICLES; FLUORESCENT-PROBE; CARBON; SENSOR; ELECTRODE; REDUCTION;
D O I
10.1021/acsanm.8b00076
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In the present work, we describe a facile, green, and template-free solvothermal fabrication of vanadium sulfide (VS2) nanoparticles (NPs) and their application for the electrochemical detection of hydrogen peroxide (H2O2) and glucose. The morphology and composition of as-prepared samples were well-characterized by powder X-ray diffraction, energy-dispersive spectroscopy, transmission electron microscopy, scanning electron microscopy, UV-vis spectroscopy, and Brunauer-Emmett-Teller surface area measurement. Because of their interesting electrochemical responses toward H2O2, a novel nonenzymatic electrochemical sensor for H2O2 and glucose detection has been proposed based on a VS2 NP-modified glassy carbon electrode. The modified electrode showed an excellent electrochemical performance for the selective and sensitive nonenzymatic detection of H2O2 in a broad concentration range of 0.5 mu M to 3.0 mM, with a wide linear range of 0.5 mu M to 2.5 mM and a lower detection limit of 0.224 mu M. The newly developed sensor also displayed high sensitivity (41.96 mu A mM(-1)) toward the detection of glucose with a broad linear range of 0.5 mu M to 3 mM. The as-fabricated sensor also showed very high sensitivity, excellent reusability, long-term stability, and negligible interference ability. Moreover, the synthesized NPs were applied for H2O2 and glucose detection in real samples, signifying their potential application in routine H2O2 and glucose analysis. The present study reveals that as-prepared VS2 NPs are promising for electrochemical H2O2 and glucose sensing and other biological applications.
引用
收藏
页码:1339 / 1347
页数:17
相关论文
共 50 条
  • [21] Hydrogen peroxide amperometric biosensor based on a peroxidase-graphite-epoxy biocomposite
    Morales, A
    Cespedes, F
    Munoz, J
    MartinezFabrega, E
    Alegret, S
    ANALYTICA CHIMICA ACTA, 1996, 332 (2-3) : 131 - 138
  • [22] Amperometric hydrogen peroxide biosensor based on a modified gold electrode with silver nanowires
    Song, Min-Jung
    Hwang, Sung Woo
    Whang, Dongmok
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (12) : 2099 - 2105
  • [23] A mediated turnip tissue paper-based amperometric hydrogen peroxide biosensor
    Sekar, Nadia Chandra
    Ge, Liya
    Shaegh, Seyed Ali Mousavi
    Ng, Sum Huan
    Tan, Swee Ngin
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 : 336 - 342
  • [24] Amperometric hydrogen peroxide biosensor based on a modified gold electrode with silver nanowires
    Min-Jung Song
    Sung Woo Hwang
    Dongmok Whang
    Journal of Applied Electrochemistry, 2010, 40 : 2099 - 2105
  • [25] Nonenzymatic amperometric sensor of hydrogen peroxide and glucose based on Pt nanoparticles/ordered mesoporous carbon nanocomposite
    Bo, Xiangjie
    Ndamanisha, Jean Chrysostome
    Bai, Jing
    Guo, Liping
    TALANTA, 2010, 82 (01) : 85 - 91
  • [26] Amperometric biosensor for nitrite and hydrogen peroxide based on hemoglobin immobilized on gold nanoparticles/polythionine/platinum nanoparticles modified glassy carbon electrode
    Zhang, Yu
    Yuan, Ruo
    Chai, Yaqin
    Wang, Jinfen
    Zhong, Huaan
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2012, 87 (04) : 570 - 574
  • [27] Amperometric hydrogen peroxide biosensor based on the immobilization of heme proteins on gold nanoparticles-bacteria cellulose nanofibers nanocomposite
    Wang, Wei
    Zhang, Tai-Ji
    Zhang, De-Wen
    Li, Hong-Yi
    Ma, Yu-Rong
    Qi, Li-Min
    Zhou, Ying-Lin
    Zhang, Xin-Xiang
    TALANTA, 2011, 84 (01) : 71 - 77
  • [28] Pectin coated polyaniline nanoparticles for an amperometric glucose biosensor
    Thakur, Bhawana
    Amarnath, Chellachamy A.
    Sawant, Shilpa N.
    RSC ADVANCES, 2014, 4 (77): : 40917 - 40923
  • [29] Inhibitive determination of metal ions by an amperometric glucose oxidase biosensor - Study of the effect of hydrogen peroxide decomposition
    Guascito, Maria Rachele
    Malitesta, Cosimino
    Mazzotta, Elisabetta
    Turco, Antonio
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 131 (02): : 394 - 402
  • [30] Hydrogen peroxide sensitive amperometric biosensor based on horseradish peroxidase entrapped in a polypyrrole electrode
    Razola, SS
    Ruiz, BL
    Diez, NM
    Mark, HB
    Kauffmann, JM
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12): : 921 - 928