Newly Designed Amperometric Biosensor for Hydrogen Peroxide and Glucose Based on Vanadium Sulfide Nanoparticles

被引:47
|
作者
Sarkar, Arpita [1 ]
Ghosh, Abhisek Brata [1 ]
Saha, Namrata [1 ]
Bhadu, Gopala Ram [2 ]
Adhikary, Bibhutosh [1 ]
机构
[1] Indian Inst Engn Sci & Technol, Dept Chem, Howrah 711103, W Bengal, India
[2] Cent Salt & Marine Chem Res Inst, Dept Analyt Sci, Gijubhai Badheka Marg, Bhavnagar 364002, Gujarat, India
来源
ACS APPLIED NANO MATERIALS | 2018年 / 1卷 / 03期
关键词
VS2; NPs; fabrication; modified electrode; biosensing; amperometric biosensor; DIRECT ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL SENSING PLATFORM; REDUCED GRAPHENE OXIDE; NONENZYMATIC DETECTION; GOLD NANOPARTICLES; FLUORESCENT-PROBE; CARBON; SENSOR; ELECTRODE; REDUCTION;
D O I
10.1021/acsanm.8b00076
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In the present work, we describe a facile, green, and template-free solvothermal fabrication of vanadium sulfide (VS2) nanoparticles (NPs) and their application for the electrochemical detection of hydrogen peroxide (H2O2) and glucose. The morphology and composition of as-prepared samples were well-characterized by powder X-ray diffraction, energy-dispersive spectroscopy, transmission electron microscopy, scanning electron microscopy, UV-vis spectroscopy, and Brunauer-Emmett-Teller surface area measurement. Because of their interesting electrochemical responses toward H2O2, a novel nonenzymatic electrochemical sensor for H2O2 and glucose detection has been proposed based on a VS2 NP-modified glassy carbon electrode. The modified electrode showed an excellent electrochemical performance for the selective and sensitive nonenzymatic detection of H2O2 in a broad concentration range of 0.5 mu M to 3.0 mM, with a wide linear range of 0.5 mu M to 2.5 mM and a lower detection limit of 0.224 mu M. The newly developed sensor also displayed high sensitivity (41.96 mu A mM(-1)) toward the detection of glucose with a broad linear range of 0.5 mu M to 3 mM. The as-fabricated sensor also showed very high sensitivity, excellent reusability, long-term stability, and negligible interference ability. Moreover, the synthesized NPs were applied for H2O2 and glucose detection in real samples, signifying their potential application in routine H2O2 and glucose analysis. The present study reveals that as-prepared VS2 NPs are promising for electrochemical H2O2 and glucose sensing and other biological applications.
引用
收藏
页码:1339 / 1347
页数:17
相关论文
共 50 条
  • [31] A novel amperometric hydrogen peroxide biosensor based on electrospun Hb-collagen composite
    Guo, F.
    Xu, X. X.
    Sun, Z. Z.
    Zhang, J. X.
    Meng, Z. X.
    Zheng, W.
    Zhou, H. M.
    Wang, B. L.
    Zheng, Y. F.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 86 (01) : 140 - 145
  • [32] Amperometric hydrogen peroxide biosensor based on immobilization of peroxidase in chitosan matrix crosslinked with glutaraldehyde
    Miao, YQ
    Tan, SN
    ANALYST, 2000, 125 (09) : 1591 - 1594
  • [33] Amperometric Glucose Biosensor Based on Electrochemically Deposited Gold Nanoparticles Covered by Polypyrrole
    German, Natalija
    Ramanavicius, Arunas
    Ramanaviciene, Almira
    ELECTROANALYSIS, 2017, 29 (05) : 1267 - 1277
  • [34] Immobilizing Pt nanoparticles and chitosan hybrid film on polyaniline naofibers membrane for an amperometric hydrogen peroxide biosensor
    Chen, Shihong
    Fu, Ping
    Yin, Bing
    Yuan, Ruo
    Chai, Yaqin
    Xiang, Yun
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2011, 34 (06) : 711 - 719
  • [35] Immobilizing Pt nanoparticles and chitosan hybrid film on polyaniline naofibers membrane for an amperometric hydrogen peroxide biosensor
    Shihong Chen
    Ping Fu
    Bing Yin
    Ruo Yuan
    Yaqin Chai
    Yun Xiang
    Bioprocess and Biosystems Engineering, 2011, 34 : 711 - 719
  • [36] Non-Enzymatic Amperometric Sensing of Hydrogen Peroxide Based on Vanadium Pentoxide Nanostructures
    Ghanei-Motlagh, Masoud
    Taher, Mohammad Ali
    Fayazi, Maryam
    Baghayeri, Mehdi
    Hosseinifar, AbduRahman
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (06) : B367 - B372
  • [37] QUANTITATIVE ANALYSIS OF PERFORMANCE OF A HYDROGEN PEROXIDE-BASED GLUCOSE BIOSENSOR
    Aziz, Azila Abd.
    JURNAL TEKNOLOGI, 2009, 51
  • [38] Fabrication of cuprous sulfide nanorods supported on copper foam for nonenzymatic amperometric determination of glucose and hydrogen peroxide
    Lu, Wangdong
    Sun, Yujing
    Dai, Haichao
    Ni, Pengjuan
    Jiang, Shu
    Wang, Yilin
    Li, Zhen
    Li, Zhuang
    RSC ADVANCES, 2016, 6 (93): : 90732 - 90738
  • [39] Amperometric hydrogen peroxide biosensor based on the immobilization of HRP on DNA-silver nanohybrids and PDDA-protected gold nanoparticles
    Ma, Liping
    Yuan, Ruo
    Chai, Yaqin
    Chen, Shihong
    JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2009, 56 (04) : 215 - 220
  • [40] Amperometric third-generation hydrogen peroxide biosensor based on the immobilization of hemoglobin on multiwall carbon nanotubes and gold colloidal nanoparticles
    Chen, Shihong
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Lingyan
    Wang, Na
    Li, Xuelian
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (07): : 1268 - 1274