Reliability of manual and semi-automated measurements of nuchal translucency by experienced operators

被引:1
|
作者
Pruksanusak, Ninlapa [1 ]
Pranpanus, Savitree [1 ]
Suwanrath, Chitkasaem [1 ]
Kor-anantakul, Ounjai [1 ]
Suntharasaj, Thitima [1 ]
Hanprasertpong, Tharangrut [1 ]
Liabsuetrakul, Tippawan [2 ]
机构
[1] Prince Songkla Univ, Dept Obstet & Gynecol, Fac Med, Hat Yai 90110, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Med, Epidemiol Unit, Hat Yai 90110, Songkhla, Thailand
关键词
Nuchal translucency; Reliability; Semi-automated measurement; THICKNESS; TRISOMY-21; SYSTEM;
D O I
10.1016/j.ijgo.2013.01.019
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To compare intra-/inter-operator reliability of manual and semi-automated NT measurement by experienced operators. Methods: Images of 103 fetuses at 11 to 13 + 6 weeks were selected. Two operators performed NT measurement independently 3 times each using both manual and semi-automated methods. Intraoperator reliability of the methods was evaluated using ICCs; interoperator reliability was assessed via correlation between the means of the 3 measurements of each operator. Agreement between the 2 methods was evaluated via Bland-Altman plot. Results: ICCs for the manual method were 0.80 (95% CI, 0.73-0.85) for operator 1 and 0.82 (95% CI, 0.76-0.87) for operator 2; ICCs for the semi-automated method were 0.80 (95% CI, 0.74-0.85) for operator 1 and 0.82 (95% CI, 0.76-0.86) for operator 2. Interoperator reliability for both methods was high: correlation coefficients 0.91 (95% CI, 0.87-0.94) and 0.96 (95% CI, 0.94-0.97) for manual and semi-automated methods, respectively. Mean NT measured by manual and semi-automated methods was 1.15 mm and 1.28 mm, respectively (P < 0.001). Agreement between the methods was good. Conclusion: The reliability of semi-automated NT measurements was comparable to that of the manual method. The new method was reproducible and may be used instead of the manual method in the normal range of NT. (C) 2013 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:240 / 242
页数:3
相关论文
共 50 条
  • [31] Comparison between manual and semi-automated radiographic scoring in rheumatoid arthritis
    Lim, Y. M. J.
    Gregory, J. S.
    Barr, R. J.
    Basu, N.
    Secombes, K.
    Reid, D. M.
    SCOTTISH MEDICAL JOURNAL, 2015, 60 (03) : E30 - E31
  • [32] A Practical Guide to Manual and Semi-Automated Neurosurgical Brain Lesion Segmentation
    Jain, R.
    Lee, F.
    Luo, N.
    Pandit, A.
    BRITISH JOURNAL OF SURGERY, 2024, 111
  • [33] Manual and semi-automated morphological analysis of Penicillium chrysogenum chemostat cultures
    McIntyre, M
    Berry, DR
    Eade, JK
    Cox, PW
    Thomas, CR
    McNeil, B
    BIOTECHNOLOGY TECHNIQUES, 1998, 12 (09) : 671 - 675
  • [34] NASCET Percent Stenosis Semi-Automated Versus Manual Measurement on CTA
    Lian, Kevin
    White, Jeremy H.
    Bartlett, Eric S.
    Bharatha, Aditya
    Aviv, Richard I.
    Fox, Allan J.
    Symons, Sean P.
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2012, 39 (03) : 343 - 346
  • [35] Ultrasound diaphragmatic manual and semi-automated motion measurements: Application in simulated and in vivo data of critically ill subjects
    Loizou, Christos P.
    Chrysostomou, Constantinos
    Minas, Giorgos
    Pattichis, Constantinos S.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 194
  • [36] Semi-automated shear stress measurements in developing embryonic hearts
    Elahi, Sahar
    Blackburn, Brecken J.
    Lapierre-Landry, Maryse
    Gu, Shi
    Rollins, Andrew M.
    Jenkins, Michael W.
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (09) : 5297 - 5305
  • [37] Keeping the driver in the loop through semi-automated or manual lane changes in conditionally automated driving
    Dillmann, J.
    den Hartigh, R. J. R.
    Kurpiers, C. M.
    Pelzer, J.
    Raisch, F. K.
    Cox, R. F. A.
    de Waard, D.
    ACCIDENT ANALYSIS AND PREVENTION, 2021, 162
  • [38] Reproducibility of manual and semi-automated late enhancement quantification in patients with Fabry disease
    Machann, Wolfram
    Geier, Oliver
    Koeppe, Sabrina
    O'Donnell, Thomas
    Greiser, Andreas
    Breunig, Frank
    Sandstede, Joern
    Hahn, Dietbert
    Koestler, Herbert
    Beer, Meinrad
    ACTA RADIOLOGICA, 2014, 55 (02) : 155 - 160
  • [39] Manual and semi-automated detection of major genetic risk factors for venous thrombosis
    Oberkanins, C
    Kury, F
    BRITISH JOURNAL OF HAEMATOLOGY, 1998, 102 (01) : 259 - 259
  • [40] Evaluation of reproducibility for manual and semi-automated feature extraction in CT and MR images
    Ashton, EA
    Molinelli, L
    Totterman, S
    Parker, KJ
    2002 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL III, PROCEEDINGS, 2002, : 161 - 164