Reliability of manual and semi-automated measurements of nuchal translucency by experienced operators

被引:1
|
作者
Pruksanusak, Ninlapa [1 ]
Pranpanus, Savitree [1 ]
Suwanrath, Chitkasaem [1 ]
Kor-anantakul, Ounjai [1 ]
Suntharasaj, Thitima [1 ]
Hanprasertpong, Tharangrut [1 ]
Liabsuetrakul, Tippawan [2 ]
机构
[1] Prince Songkla Univ, Dept Obstet & Gynecol, Fac Med, Hat Yai 90110, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Med, Epidemiol Unit, Hat Yai 90110, Songkhla, Thailand
关键词
Nuchal translucency; Reliability; Semi-automated measurement; THICKNESS; TRISOMY-21; SYSTEM;
D O I
10.1016/j.ijgo.2013.01.019
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To compare intra-/inter-operator reliability of manual and semi-automated NT measurement by experienced operators. Methods: Images of 103 fetuses at 11 to 13 + 6 weeks were selected. Two operators performed NT measurement independently 3 times each using both manual and semi-automated methods. Intraoperator reliability of the methods was evaluated using ICCs; interoperator reliability was assessed via correlation between the means of the 3 measurements of each operator. Agreement between the 2 methods was evaluated via Bland-Altman plot. Results: ICCs for the manual method were 0.80 (95% CI, 0.73-0.85) for operator 1 and 0.82 (95% CI, 0.76-0.87) for operator 2; ICCs for the semi-automated method were 0.80 (95% CI, 0.74-0.85) for operator 1 and 0.82 (95% CI, 0.76-0.86) for operator 2. Interoperator reliability for both methods was high: correlation coefficients 0.91 (95% CI, 0.87-0.94) and 0.96 (95% CI, 0.94-0.97) for manual and semi-automated methods, respectively. Mean NT measured by manual and semi-automated methods was 1.15 mm and 1.28 mm, respectively (P < 0.001). Agreement between the methods was good. Conclusion: The reliability of semi-automated NT measurements was comparable to that of the manual method. The new method was reproducible and may be used instead of the manual method in the normal range of NT. (C) 2013 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:240 / 242
页数:3
相关论文
共 50 条
  • [21] Reliability of semi-automated spinal measurement software
    Follett, Matthew
    Karamian, Brian
    Liu, Ning
    Alamin, Todd
    Wood, Kirkham B.
    SPINE DEFORMITY, 2024, 12 (02) : 323 - 327
  • [22] A Manual, Semi-Automated and Automated ROI Study of fMRI Hemodynamic Response
    Zhang, Jing
    Buchsbaum, Monte S.
    Chu, King-Wai
    Hazlett, Erin A.
    MEDINFO 2013: PROCEEDINGS OF THE 14TH WORLD CONGRESS ON MEDICAL AND HEALTH INFORMATICS, PTS 1 AND 2, 2013, 192 : 921 - 921
  • [23] Observer evaluation of semi-automated mesothelioma measurements
    Armato, S
    Oxnard, G
    Kocherginsky, M
    Vogelzang, N
    Kindler, H
    MacMahon, H
    MEDICAL PHYSICS, 2005, 32 (06) : 2121 - 2121
  • [24] Semi-automated quantitative Drosophila wings measurements
    Sheng Yang Michael Loh
    Yoshitaka Ogawa
    Sara Kawana
    Koichiro Tamura
    Hwee Kuan Lee
    BMC Bioinformatics, 18
  • [25] Semi-automated quantitative Drosophila wings measurements
    Loh, Sheng Yang Michael
    Ogawa, Yoshitaka
    Kawana, Sara
    Tamura, Koichiro
    Lee, Hwee Kuan
    BMC BIOINFORMATICS, 2017, 18
  • [26] Manual and semi-automated classification in a microscopic artificial life model
    Hawick, KA
    James, HA
    Scogings, CJ
    Proceedings of the IASTED International Conference on Computational Intelligence, 2005, : 135 - 140
  • [27] A comparison of manual and semi-automated methods in the assessment of axonal injury
    Gentleman, SM
    McKenzie, JE
    Royston, MC
    McIntosh, TK
    Graham, DI
    NEUROPATHOLOGY AND APPLIED NEUROBIOLOGY, 1999, 25 (01) : 41 - 47
  • [28] Manual, semi-automated, and automated delineation of chronic brain lesions: A comparison of methods
    Wilke, Marko
    de Haan, Bianca
    Juenger, Hendrik
    Karnath, Hans-Otto
    NEUROIMAGE, 2011, 56 (04) : 2038 - 2046
  • [29] Interobserver agreement of semi-automated and manual measurements of functional MRI metrics of treatment response in hepatocellular carcinoma
    Bonekamp, David
    Bonekamp, Susanne
    Halappa, Vivek Gowdra
    Geschwind, Jean-Francois H.
    Eng, John
    Corona-Villalobos, Celia Pamela
    Pawlik, Timothy M.
    Kamel, Ihab R.
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (03) : 487 - 496
  • [30] A semi-automated method for retinal vessel measurements.
    Quigley, MG
    Campeanu, RI
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S83 - S83