Reliability of manual and semi-automated measurements of nuchal translucency by experienced operators

被引:1
|
作者
Pruksanusak, Ninlapa [1 ]
Pranpanus, Savitree [1 ]
Suwanrath, Chitkasaem [1 ]
Kor-anantakul, Ounjai [1 ]
Suntharasaj, Thitima [1 ]
Hanprasertpong, Tharangrut [1 ]
Liabsuetrakul, Tippawan [2 ]
机构
[1] Prince Songkla Univ, Dept Obstet & Gynecol, Fac Med, Hat Yai 90110, Songkhla, Thailand
[2] Prince Songkla Univ, Fac Med, Epidemiol Unit, Hat Yai 90110, Songkhla, Thailand
关键词
Nuchal translucency; Reliability; Semi-automated measurement; THICKNESS; TRISOMY-21; SYSTEM;
D O I
10.1016/j.ijgo.2013.01.019
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To compare intra-/inter-operator reliability of manual and semi-automated NT measurement by experienced operators. Methods: Images of 103 fetuses at 11 to 13 + 6 weeks were selected. Two operators performed NT measurement independently 3 times each using both manual and semi-automated methods. Intraoperator reliability of the methods was evaluated using ICCs; interoperator reliability was assessed via correlation between the means of the 3 measurements of each operator. Agreement between the 2 methods was evaluated via Bland-Altman plot. Results: ICCs for the manual method were 0.80 (95% CI, 0.73-0.85) for operator 1 and 0.82 (95% CI, 0.76-0.87) for operator 2; ICCs for the semi-automated method were 0.80 (95% CI, 0.74-0.85) for operator 1 and 0.82 (95% CI, 0.76-0.86) for operator 2. Interoperator reliability for both methods was high: correlation coefficients 0.91 (95% CI, 0.87-0.94) and 0.96 (95% CI, 0.94-0.97) for manual and semi-automated methods, respectively. Mean NT measured by manual and semi-automated methods was 1.15 mm and 1.28 mm, respectively (P < 0.001). Agreement between the methods was good. Conclusion: The reliability of semi-automated NT measurements was comparable to that of the manual method. The new method was reproducible and may be used instead of the manual method in the normal range of NT. (C) 2013 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:240 / 242
页数:3
相关论文
共 50 条
  • [41] Semi-automated analysis of coronary flow Doppler images: Validation with manual tracings
    Magagnin, V.
    Caiani, E. G.
    Delfino, L.
    Champlon, C.
    Cerutti, S.
    Turiel, M.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3703 - +
  • [42] Evaluation of manual vs semi-automated delineation of liver lesions on CT images
    E. Bellon
    M. Feron
    F. Maes
    L. Van Hoe
    D. Delaere
    F. Haven
    S. Sunaert
    A. L. Baert
    G. Marchal
    P. Suetens
    European Radiology, 1997, 7 : 432 - 438
  • [43] Manual and semi-automated detection of major genetic risk factors for venous thrombosis
    Oberkanins, C
    Kury, F
    EUROPEAN JOURNAL OF HUMAN GENETICS, 1998, 6 : 62 - 62
  • [44] Evaluation of manual vs semi-automated delineation of liver lesions on CT images
    Bellon, E
    Feron, M
    Maes, F
    VanHoe, L
    Delaere, D
    Haven, F
    Sunaert, S
    Baert, AL
    Marchal, G
    EUROPEAN RADIOLOGY, 1997, 7 (03) : 432 - 438
  • [45] A precision cryostat design for manual and semi-automated cryo-plunge instruments
    Russo, Christopher J.
    Scotcher, Steve
    Kyte, Martin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [46] Examining Manual and Semi-Automated Methods of Analysing MOOC Data for Computing Education
    Morgan, Michael
    Butler, Matthew
    Thota, Neena
    Nylen, Aletta
    Eckerdal, Anna
    Kinnunen, Paivi
    17TH KOLI CALLING INTERNATIONAL CONFERENCE ON COMPUTING EDUCATION RESEARCH (KOLI CALLING 2017), 2017, : 153 - 157
  • [47] Reliability of the Percent Density in Digital Mammography with a Semi-Automated Thresholding Method
    Sohn, Guiyun
    Lee, Jong Won
    Park, Sung Won
    Park, Jihoon
    Woo, Jiyoung
    Kim, Hwa Jung
    Shin, Hee Jung
    Kim, Hak Hee
    Jung, Kyung Hae
    Sung, Joohon
    Lee, Seung Wook
    Son, Byung Ho
    Ahn, Sei-Hyun
    JOURNAL OF BREAST CANCER, 2014, 17 (02) : 174 - 179
  • [48] Reliability of a semi-automated technique of cerebral infarct volume measurement with CT
    Gavin, CM
    Smith, CJ
    Emsley, HCA
    Hughes, DG
    Turnbull, IW
    Vail, A
    Tyrrell, PJ
    CEREBROVASCULAR DISEASES, 2004, 18 (03) : 220 - 226
  • [49] Semi-automated measurement of hyperdense, hypodense and heterogeneous hepatic metastasis on standard MDCT slices. Comparison of semi-automated and manual measurement of RECIST and WHO criteria
    Keil, Sebastian
    Behrendt, Florian F.
    Stanzel, Sven
    Suehling, Michael
    Koch, Alexander
    Bubenzer, Jhenee
    Muehlenbruch, Georg
    Mahnken, Andreas H.
    Guenther, Rolf W.
    Das, Marco
    EUROPEAN RADIOLOGY, 2008, 18 (11) : 2456 - 2465
  • [50] Semi-automated measurement of hyperdense, hypodense and heterogeneous hepatic metastasis on standard MDCT slices. Comparison of semi-automated and manual measurement of RECIST and WHO criteria
    Sebastian Keil
    Florian F. Behrendt
    Sven Stanzel
    Michael Sühling
    Alexander Koch
    Jhenee Bubenzer
    Georg Mühlenbruch
    Andreas H. Mahnken
    Rolf W. Günther
    Marco Das
    European Radiology, 2008, 18 : 2456 - 2465