NASCET Percent Stenosis Semi-Automated Versus Manual Measurement on CTA

被引:9
|
作者
Lian, Kevin [1 ]
White, Jeremy H. [1 ]
Bartlett, Eric S. [1 ]
Bharatha, Aditya [1 ]
Aviv, Richard I. [1 ]
Fox, Allan J. [1 ]
Symons, Sean P. [1 ]
机构
[1] Univ Toronto, Sunnybrook Hlth Sci Ctr, Div Neuroradiol, Dept Med Imaging, Toronto, ON M4N 3M5, Canada
关键词
CAROTID-ARTERY STENOSIS; ANGIOGRAPHY; REPRODUCIBILITY; ENDARTERECTOMY; QUANTIFICATION; OCCLUSION;
D O I
10.1017/S0317167100013482
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose: To compare North American Symptomatic Carotid Endarterectomy Trial (NASCET) stenosis values and NASCET grade categorization (mild, moderate, severe) of semi-automated vessel analysis software versus manual measurements on computed tomography angiography (CTA). Methods: There were four observers. Two independently analyzed 8 I carotid artery CTAs using semi-automated vessel analysis software according to a blinded protocol. The software measured the narrowest stenosis in millimeters (mm), distal internal carotid artery (ICA) in mm, and calculated percent stenosis based on NASCET criteria. One of these two observers performed this task twice on each carotid, the second analysis was delayed two months in order to mitigate recall bias. Two other observers manually measured the narrowest stenosis in mm, distal ICA in mm, and calculated NASCET percent stenosis in a blinded fashion. The calculated NASCET stenoses were categorized into mild, moderate, or severe. Chi square and analysis of variance (ANOVA) were used to test for statistical differences. Results: ANOVA did not find a statistically significant difference in the mean percent stenosis when comparing the two manual measurements, the two semi-automated measurements, and the repeat semi-automated. Chi square demonstrated that the distribution of grades of stenosis were statistically different (p<0.05) between the manual and semi-automated grades. Semi-automated vessel analysis tended to underestimate the degree of stenosis compared to manual measurement. Conclusion: The mean percentage stenosis determined by semi-automated vessel analysis is not significantly different from manual measurement. However, when the data is categorized into mild, moderate and severe stenosis, there is a significant difference between semi-automated and manual measurements. The semi-automated software tends to underestimate the stenosis grade compared to manual measurement.
引用
收藏
页码:343 / 346
页数:4
相关论文
共 50 条
  • [1] Reproducibility of Semi-Automated Measurement of Carotid Stenosis on CTA
    White, Jeremy H.
    Bartlett, Eric S.
    Bharatha, Aditya
    Aviv, Richard I.
    Fox, Allan J.
    Thompson, Andrew L.
    Bitar, Richard
    Symons, Sean P.
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2010, 37 (04) : 498 - 503
  • [2] MANUAL AND SEMI-AUTOMATED PROCEDURES FOR MEASUREMENT OF TRIGLYCERIDES
    GIEGEL, J
    TRINIDAD, E
    SOLONI, F
    COHEN, B
    CLEMA, W
    CLINICAL CHEMISTRY, 1972, 18 (07) : 693 - &
  • [3] Manual Versus Semi-Automated Measurement of Geographic Atrophy Area in Eyes With Age-Related Macular Degeneration
    Mahmoudzadeh, Raziyeh
    Salabati, Mirataollah
    Khan, M. Ali
    Garg, Sunir J.
    Hsu, Jason
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (09):
  • [4] The influence of image setting on intracranial translucency measurement by manual and semi-automated system
    Zhen, Li
    Yang, Xin
    Ting, Yuen Ha
    Chen, Min
    Leung, Tak Yeung
    PRENATAL DIAGNOSIS, 2013, 33 (09) : 889 - 893
  • [5] Evaluation of mixed semi-automated/manual traffic
    Bose, A
    Ioannou, P
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, VOLS 1 AND 2, 1996, : 868 - 872
  • [6] Semi-automated measurement of hyperdense, hypodense and heterogeneous hepatic metastasis on standard MDCT slices. Comparison of semi-automated and manual measurement of RECIST and WHO criteria
    Sebastian Keil
    Florian F. Behrendt
    Sven Stanzel
    Michael Sühling
    Alexander Koch
    Jhenee Bubenzer
    Georg Mühlenbruch
    Andreas H. Mahnken
    Rolf W. Günther
    Marco Das
    European Radiology, 2008, 18 : 2456 - 2465
  • [7] Semi-automated measurement of hyperdense, hypodense and heterogeneous hepatic metastasis on standard MDCT slices. Comparison of semi-automated and manual measurement of RECIST and WHO criteria
    Keil, Sebastian
    Behrendt, Florian F.
    Stanzel, Sven
    Suehling, Michael
    Koch, Alexander
    Bubenzer, Jhenee
    Muehlenbruch, Georg
    Mahnken, Andreas H.
    Guenther, Rolf W.
    Das, Marco
    EUROPEAN RADIOLOGY, 2008, 18 (11) : 2456 - 2465
  • [8] Manual segmentation versus semi-automated segmentation for quantifying vestibular schwannoma volume on MRI
    Hari McGrath
    Peichao Li
    Reuben Dorent
    Robert Bradford
    Shakeel Saeed
    Sotirios Bisdas
    Sebastien Ourselin
    Jonathan Shapey
    Tom Vercauteren
    International Journal of Computer Assisted Radiology and Surgery, 2020, 15 : 1445 - 1455
  • [9] Comparison of semi-automated versus manual quantitative right ventricular assessment in tetralogy of Fallot
    Lowisz, Joanna
    Alenghat, Francis J.
    Li, Yi
    Roberson, David
    Penk, Jamie
    Gandhi, Rupali
    CARDIOLOGY IN THE YOUNG, 2021, 31 (11) : 1781 - 1787
  • [10] Comparison of manual versus semi-automated analysis methods for pterygium surface area determination
    Lien, Brandon
    Shin, Ye Jin
    Lee, Olivia L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)