NASCET Percent Stenosis Semi-Automated Versus Manual Measurement on CTA

被引:9
|
作者
Lian, Kevin [1 ]
White, Jeremy H. [1 ]
Bartlett, Eric S. [1 ]
Bharatha, Aditya [1 ]
Aviv, Richard I. [1 ]
Fox, Allan J. [1 ]
Symons, Sean P. [1 ]
机构
[1] Univ Toronto, Sunnybrook Hlth Sci Ctr, Div Neuroradiol, Dept Med Imaging, Toronto, ON M4N 3M5, Canada
关键词
CAROTID-ARTERY STENOSIS; ANGIOGRAPHY; REPRODUCIBILITY; ENDARTERECTOMY; QUANTIFICATION; OCCLUSION;
D O I
10.1017/S0317167100013482
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose: To compare North American Symptomatic Carotid Endarterectomy Trial (NASCET) stenosis values and NASCET grade categorization (mild, moderate, severe) of semi-automated vessel analysis software versus manual measurements on computed tomography angiography (CTA). Methods: There were four observers. Two independently analyzed 8 I carotid artery CTAs using semi-automated vessel analysis software according to a blinded protocol. The software measured the narrowest stenosis in millimeters (mm), distal internal carotid artery (ICA) in mm, and calculated percent stenosis based on NASCET criteria. One of these two observers performed this task twice on each carotid, the second analysis was delayed two months in order to mitigate recall bias. Two other observers manually measured the narrowest stenosis in mm, distal ICA in mm, and calculated NASCET percent stenosis in a blinded fashion. The calculated NASCET stenoses were categorized into mild, moderate, or severe. Chi square and analysis of variance (ANOVA) were used to test for statistical differences. Results: ANOVA did not find a statistically significant difference in the mean percent stenosis when comparing the two manual measurements, the two semi-automated measurements, and the repeat semi-automated. Chi square demonstrated that the distribution of grades of stenosis were statistically different (p<0.05) between the manual and semi-automated grades. Semi-automated vessel analysis tended to underestimate the degree of stenosis compared to manual measurement. Conclusion: The mean percentage stenosis determined by semi-automated vessel analysis is not significantly different from manual measurement. However, when the data is categorized into mild, moderate and severe stenosis, there is a significant difference between semi-automated and manual measurements. The semi-automated software tends to underestimate the stenosis grade compared to manual measurement.
引用
收藏
页码:343 / 346
页数:4
相关论文
共 50 条
  • [21] Manual and semi-automated classification in a microscopic artificial life model
    Hawick, KA
    James, HA
    Scogings, CJ
    Proceedings of the IASTED International Conference on Computational Intelligence, 2005, : 135 - 140
  • [22] A comparison of manual and semi-automated methods in the assessment of axonal injury
    Gentleman, SM
    McKenzie, JE
    Royston, MC
    McIntosh, TK
    Graham, DI
    NEUROPATHOLOGY AND APPLIED NEUROBIOLOGY, 1999, 25 (01) : 41 - 47
  • [23] Manual, semi-automated, and automated delineation of chronic brain lesions: A comparison of methods
    Wilke, Marko
    de Haan, Bianca
    Juenger, Hendrik
    Karnath, Hans-Otto
    NEUROIMAGE, 2011, 56 (04) : 2038 - 2046
  • [24] Accuracy of semi-automated versus manual localisation of liver tumours in CT-guided ablation procedures
    Hassan Boulkhrif
    Ha Manh Luu
    Theo van Walsum
    Adriaan Moelker
    European Radiology, 2018, 28 : 4978 - 4984
  • [25] Accuracy of semi-automated versus manual localisation of liver tumours in CT-guided ablation procedures
    Boulkhrif, Hassan
    Ha Manh Luu
    van Walsum, Theo
    Moelker, Adriaan
    EUROPEAN RADIOLOGY, 2018, 28 (12) : 4978 - 4984
  • [26] Comparison of Semi-Automated Versus Manual Quantitative Right Ventricular Assessment in Hypoplastic Left Heart Syndrome
    Jamie Penk
    Shireen Mukadam
    S. Javed Zaidi
    Vivian Cui
    Robert Metzger
    David A. Roberson
    Yi Li
    Pediatric Cardiology, 2020, 41 : 69 - 76
  • [27] Comparison of Semi-Automated Versus Manual Quantitative Right Ventricular Assessment in Hypoplastic Left Heart Syndrome
    Penk, Jamie
    Mukadam, Shireen
    Zaidi, S. Javed
    Cui, Vivian
    Metzger, Robert
    Roberson, David A.
    Li, Yi
    PEDIATRIC CARDIOLOGY, 2020, 41 (01) : 69 - 76
  • [28] Manual and Semi-Automated Measurement and Calculation of Osteosarcoma Treatment Effect Using Whole Slide Image and Qupath
    He, Mai
    He, Bofan
    Weng, Jinyi
    Cheng, Jerry Q.
    Gu, Huanying
    PEDIATRIC AND DEVELOPMENTAL PATHOLOGY, 2024, 27 (01) : 32 - 38
  • [29] Reliability of the Percent Density in Digital Mammography with a Semi-Automated Thresholding Method
    Sohn, Guiyun
    Lee, Jong Won
    Park, Sung Won
    Park, Jihoon
    Woo, Jiyoung
    Kim, Hwa Jung
    Shin, Hee Jung
    Kim, Hak Hee
    Jung, Kyung Hae
    Sung, Joohon
    Lee, Seung Wook
    Son, Byung Ho
    Ahn, Sei-Hyun
    JOURNAL OF BREAST CANCER, 2014, 17 (02) : 174 - 179
  • [30] Semi-automated quantification and segmentation of abdominal aorta aneurysms from CTA volumes
    Wink, O
    Niessen, WJ
    Wever, JJ
    Broeders, IAJM
    Blankensteijn, JD
    Viergever, MA
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 208 - 212