NASCET Percent Stenosis Semi-Automated Versus Manual Measurement on CTA

被引:9
|
作者
Lian, Kevin [1 ]
White, Jeremy H. [1 ]
Bartlett, Eric S. [1 ]
Bharatha, Aditya [1 ]
Aviv, Richard I. [1 ]
Fox, Allan J. [1 ]
Symons, Sean P. [1 ]
机构
[1] Univ Toronto, Sunnybrook Hlth Sci Ctr, Div Neuroradiol, Dept Med Imaging, Toronto, ON M4N 3M5, Canada
关键词
CAROTID-ARTERY STENOSIS; ANGIOGRAPHY; REPRODUCIBILITY; ENDARTERECTOMY; QUANTIFICATION; OCCLUSION;
D O I
10.1017/S0317167100013482
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose: To compare North American Symptomatic Carotid Endarterectomy Trial (NASCET) stenosis values and NASCET grade categorization (mild, moderate, severe) of semi-automated vessel analysis software versus manual measurements on computed tomography angiography (CTA). Methods: There were four observers. Two independently analyzed 8 I carotid artery CTAs using semi-automated vessel analysis software according to a blinded protocol. The software measured the narrowest stenosis in millimeters (mm), distal internal carotid artery (ICA) in mm, and calculated percent stenosis based on NASCET criteria. One of these two observers performed this task twice on each carotid, the second analysis was delayed two months in order to mitigate recall bias. Two other observers manually measured the narrowest stenosis in mm, distal ICA in mm, and calculated NASCET percent stenosis in a blinded fashion. The calculated NASCET stenoses were categorized into mild, moderate, or severe. Chi square and analysis of variance (ANOVA) were used to test for statistical differences. Results: ANOVA did not find a statistically significant difference in the mean percent stenosis when comparing the two manual measurements, the two semi-automated measurements, and the repeat semi-automated. Chi square demonstrated that the distribution of grades of stenosis were statistically different (p<0.05) between the manual and semi-automated grades. Semi-automated vessel analysis tended to underestimate the degree of stenosis compared to manual measurement. Conclusion: The mean percentage stenosis determined by semi-automated vessel analysis is not significantly different from manual measurement. However, when the data is categorized into mild, moderate and severe stenosis, there is a significant difference between semi-automated and manual measurements. The semi-automated software tends to underestimate the stenosis grade compared to manual measurement.
引用
收藏
页码:343 / 346
页数:4
相关论文
共 50 条
  • [41] Measurement of Upper-Limb Joint Angular Kinematics: A Comparative Study in Manual and Semi-automated Assembly Line
    Abreu, Ana Betty
    Santos, Joana
    Baptista, Joao
    SHO2015: INTERNATIONAL SYMPOSIUM ON OCCUPATIONAL SAFETY AND HYGIENE, 2015, : 1 - 3
  • [42] Robust semi-automated path extraction for visualising stenosis of the coronary arteries
    Mueller, Daniel
    Maeder, Anthony
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2008, 32 (06) : 463 - 475
  • [43] ASSESSMENT AND COMPARISON OF THE MANUAL STEPS REQUIRED TO PERFORM WHOLE BLOOD PROCESSING USING A SEMI-AUTOMATED METHOD VERSUS A FULLY AUTOMATED METHOD
    Comasolivas, N.
    Barco Atehortua, G. E.
    Jaramillo Velasquez, S.
    Bejarano-Romero, A.
    Cardenas-Castiblanco, M. C.
    Perez-Carrillo, J. A.
    Manrique-Salamanca, C.
    VALUE IN HEALTH, 2024, 27 (06) : S288 - S288
  • [44] Keeping the driver in the loop through semi-automated or manual lane changes in conditionally automated driving
    Dillmann, J.
    den Hartigh, R. J. R.
    Kurpiers, C. M.
    Pelzer, J.
    Raisch, F. K.
    Cox, R. F. A.
    de Waard, D.
    ACCIDENT ANALYSIS AND PREVENTION, 2021, 162
  • [45] Semi-automated and fully automated mammographic density measurement and breastcancer risk prediction
    Llobet, Rafael
    Pollan, Marina
    Anton, Joaquin
    Miranda-Garcia, Josefa
    Casals, Maria
    Martinez, Inmaculada
    Ruiz-Perales, Francisco
    Perez-Gomez, Beatriz
    Salas-Trejo, Dolores
    Perez-Cortes, Juan-Carlos
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2014, 116 (02) : 105 - 115
  • [46] Reproducibility of manual and semi-automated late enhancement quantification in patients with Fabry disease
    Machann, Wolfram
    Geier, Oliver
    Koeppe, Sabrina
    O'Donnell, Thomas
    Greiser, Andreas
    Breunig, Frank
    Sandstede, Joern
    Hahn, Dietbert
    Koestler, Herbert
    Beer, Meinrad
    ACTA RADIOLOGICA, 2014, 55 (02) : 155 - 160
  • [47] Manual and semi-automated detection of major genetic risk factors for venous thrombosis
    Oberkanins, C
    Kury, F
    BRITISH JOURNAL OF HAEMATOLOGY, 1998, 102 (01) : 259 - 259
  • [48] Evaluation of reproducibility for manual and semi-automated feature extraction in CT and MR images
    Ashton, EA
    Molinelli, L
    Totterman, S
    Parker, KJ
    2002 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL III, PROCEEDINGS, 2002, : 161 - 164
  • [49] Semi-automated analysis of coronary flow Doppler images: Validation with manual tracings
    Magagnin, V.
    Caiani, E. G.
    Delfino, L.
    Champlon, C.
    Cerutti, S.
    Turiel, M.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 3703 - +
  • [50] Evaluation of manual vs semi-automated delineation of liver lesions on CT images
    E. Bellon
    M. Feron
    F. Maes
    L. Van Hoe
    D. Delaere
    F. Haven
    S. Sunaert
    A. L. Baert
    G. Marchal
    P. Suetens
    European Radiology, 1997, 7 : 432 - 438