Dual chamber pacing with a single-lead DDD pacing system

被引:4
|
作者
Naegeli, B [1 ]
Straumann, E
Gerber, A
Schuiki, E
Kunz, M
Niederhäuser, U
Bertel, O
机构
[1] Stadtspital Triemli, Dept Internal Med, Cardiac Unit, CH-8063 Zurich, Switzerland
[2] Stadtspital Triemli, Dept Cardiac Surg, CH-8063 Zurich, Switzerland
来源
关键词
DDD pacing; single lead;
D O I
10.1111/j.1540-8159.1999.tb00565.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The successful application of single-lead VDD pacing during the last few years hers generated the idea of single-lead DDD pacing: Preliminary data from several single-lead VDD studies attempting to pace the atrium by a floating atrial dipole are unsatisfactory, causing an unacceptably high current drain of the device. We studied thefeasibility as well as the short- and long-term stability of atrioventricular sequential pacing, using a new single-pass, tined DDD lead. In eight consecutive patients (age 73 +/- 16 years) with symptomatic higher degree A V block and intact sinus node function, this new single-pass DDD lead was implanted in combination with a. DDDR pacemaker. Correct VDD and DDD function wets studied at implantation; at discharge; and at 1, 3, and 6 months of follow-up. At implant, the atrial stimulation threshold was 0.6 +/- 0.2 V/0.5 ms. During follow-up, the atrial pacing thresholds in different everyday positions averaged 2.1 +/- 0.5 V at discharge, 2.9 +/- 0.5 V at 2 month, 3.8 +/- 0.4 V at 3 months, and 3.4 +/- 0.4 V at 6 months (pulse width always 0.5 ms). The measured P wave amplitude at implantation was 4.5 +/- 2.2 mV; during follow-up the telemetered atrial sensitivity thresholds averaged 2.2 +/- 0.3 mV. Phrenic nerve stimulation at high output pacing (5.0 V/0.5 ms) was observed in three (38%) patients at discharge and in one (13%) patient during follow-up; an intermittent unmeasurable atrial lead impedance at 3 and 6 months follow-up was documented in one (13%) patient. This study confirms the possibility of short- and long-term DDD pacing using a single-pass DDD lead. Since atrial stimulation thresholds are still relatively high compared to conventional dual-lead DDD pacing, further improvements of the atrial electrodes are desirable, enabling lower pacing thresholds and optimizing energy requirements as well as minimizing the potential disadvantage of phrenic nerve stimulation.
引用
收藏
页码:1013 / 1019
页数:7
相关论文
共 50 条
  • [21] SINGLE-LEAD VDD PACING - EXCELLENCE OR EXPEDIENCE
    KATRITSIS, D
    CAMM, AJ
    CLINICAL CARDIOLOGY, 1991, 14 (11) : 917 - 922
  • [22] Safety and effectiveness of single-lead VDD pacing
    Chabbar Boudet, Maruan C.
    Lukic, Antonella
    Galache Osuna, Jose G.
    de Juan Montiel, Jesus
    Cay Diarte, Eduardo
    Diarte de Miguel, Jose A.
    Peralta, Luis J. Placer
    REVISTA ESPANOLA DE CARDIOLOGIA, 2006, 59 (09): : 897 - 904
  • [23] The Current Status of Single Lead Dual Chamber Sensing and Pacing
    Hung-Fat Tse
    Chu-Pak Lau
    Journal of Interventional Cardiac Electrophysiology, 1998, 2 : 255 - 267
  • [24] The current status of single lead dual chamber sensing and pacing
    Tse, HF
    Lau, CP
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1998, 2 (03) : 255 - 267
  • [25] New areas of application for single lead dual chamber pacing
    Bodnár, J
    Pella, J
    Stancák, B
    Cizmárik, P
    Kalist, P
    Vajó, J
    Chyla, M
    Simon, R
    Brandebur, O
    Stebnicky, I
    Mad'ar, M
    CARDIOVASCULAR DIESEASES 2002, 2002, : 39 - 42
  • [26] Dual chamber cardiac pacing in children:: Single chamber pacing dual chamber sensing cardiac pacemaker or dual chamber pacing and sensing cardiac pacemaker?
    Bostan, ÖM
    Çeliker, A
    Karagöz, T
    Özer, S
    Özme, S
    PEDIATRICS INTERNATIONAL, 2002, 44 (06) : 635 - 640
  • [27] A NEW DUAL-CHAMBER SINGLE-LEAD SYSTEM
    HIRSCHBERG, J
    EKWALL, C
    STRANDBERG, H
    CARLSTEN, J
    BOWALD, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 1870 - 1872
  • [28] SINGLE-LEAD FOR PERMANENT VDD PACING IN SELECTED PATIENTS
    ANTONIOLI, GE
    SERMASI, S
    MARZALONI, M
    RUSCONI, L
    PERCOCO, GF
    TOSELLI, T
    BAGGIONI, GF
    POZZAR, C
    FERRARI, C
    ROSSI, F
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (04): : 496 - 496
  • [29] Implantation of a dual chamber pacing and sensing single pass defibrillation lead
    Gradaus, R
    Block, M
    Dorszewski, A
    Schriever, C
    Hammel, D
    Scheld, HH
    Borggrefe, M
    Breithardt, G
    Böcker, D
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (04): : 416 - 423
  • [30] AN IMPROVED SINGLE-LEAD ATRIAL-SYNCHRONOUS VENTRICULAR PACING SYSTEM FOR NATURAL, RATE-RESPONSIVE PACING
    GOLDREYER, BN
    BROWNLEE, RR
    SHIMMELGOLDEN, JB
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (05): : 1212 - 1212