Safety and effectiveness of single-lead VDD pacing

被引:5
|
作者
Chabbar Boudet, Maruan C. [1 ]
Lukic, Antonella [1 ]
Galache Osuna, Jose G. [1 ]
de Juan Montiel, Jesus [1 ]
Cay Diarte, Eduardo [1 ]
Diarte de Miguel, Jose A. [1 ]
Peralta, Luis J. Placer [1 ]
机构
[1] Hosp Univ Miguel Servet, Unidad Marcapasos, Serv Cardiol, Zaragoza 50011, Spain
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2006年 / 59卷 / 09期
关键词
VDD pacing; atrioventricular block; atrial undersensing; supraventricular tachyarrhythmias; sinus node disease;
D O I
10.1157/13092797
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives. Single-lead VDD pacing provides the physiological benefits of atrioventricular synchrony with the convenience of a single-lead system. However, concern remains about the method's safety and effectiveness. Method. In total, 700 patients with single-lead VDD pacemakers were evaluated retrospectively. The following parameters were recorded: age, sex, etiology, the symptoms and electrocardiographic diagnosis that justified pacemaker implantation, the venous access route used for implantation, atrial sensing at implantation, atrial undersensing at follow-up, the occurrence of supraventricular tachyarrhythmias, and final pacing mode. Results. Third-degree atrioventricular block was the main indication for pacemaker implantation (66.4%). The most commonly used venous access route was via the right cephalic vein (49.1%). At implantation, the mean atrial signal was 1.8 (4 1.15) mV. During follow-up, significant atrial undersensing occurred in 7.7% of patients; in 1.9%, it could not be corrected by device reprogramming. Uncontrollable supraventricular arrhythmias were observed in 6.4% of patients. Symptomatic sinus node disease was rare. By the end of follow-up, 91.4% of patients were still on VDD pacing, while, in 8.3%, the pacemaker had to be reprogrammed to the VVI mode. Only 0.3% required atrial lead implantation for DDD pacing. Left-side venous access during implantation was a independent predictora of atrial undersensing at follow-up. Low values of atrial detection at implant did not reach statistical signification although it showed a remarkable trend. Conclusions. Single-lead VDD pacing seems to be safe and effective when appropriately indicated. Our findings are consistent with those of previously published studies.
引用
下载
收藏
页码:897 / 904
页数:8
相关论文
共 50 条
  • [1] Single-lead VDD/DDD pacing
    Ovsyshcher, IE
    Wagshal, AB
    CARDIAC ARRHYTHMIAS, PACING & ELECTROPHYSIOLOGY: THE EXPERT VIEW, 1998, 201 : 389 - 398
  • [2] SINGLE-LEAD VDD PACING SYSTEM
    VARRIALE, P
    PILLA, AG
    TEKRIWAL, M
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (06): : 757 - 766
  • [3] SINGLE-LEAD VDD PACING - EXCELLENCE OR EXPEDIENCE
    KATRITSIS, D
    CAMM, AJ
    CLINICAL CARDIOLOGY, 1991, 14 (11) : 917 - 922
  • [4] SINGLE-LEAD FOR PERMANENT VDD PACING IN SELECTED PATIENTS
    ANTONIOLI, GE
    SERMASI, S
    MARZALONI, M
    RUSCONI, L
    PERCOCO, GF
    TOSELLI, T
    BAGGIONI, GF
    POZZAR, C
    FERRARI, C
    ROSSI, F
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (04): : 496 - 496
  • [5] Reliability of single-lead VDD atrial sensing and pacing during exercise
    Guyomar, Y
    Graux, P
    Carlioz, R
    Moulin, C
    Dutoit, A
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (12): : 1747 - 1752
  • [6] VDD PACING WITH A SINGLE-LEAD - AN EASY WAY FOR A TRUE PHYSIOLOGICAL RATE-RESPONSIVE PACING
    ANTONIOLI, GE
    SERMASI, S
    MARZALONI, M
    GIORDANO, M
    RONCAROLO, P
    BINAGHI, G
    BOSCHERINI, M
    DEPONTI, C
    GIBELLI, G
    ZANUTTINI, D
    BURELLI, C
    SGARBI, E
    RENZI, R
    SANTINI, M
    FARRIS, W
    TAMMARO, C
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (05): : 1206 - 1206
  • [7] Usefulness of echocardiography to predict inappropriate atrial sensing in single-lead VDD pacing
    De Cock, CC
    Van Campen, LC
    Huygens, J
    Kamp, O
    Visser, CA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (09): : 1344 - 1347
  • [8] Feasibility and sensing thresholds of temporary single-lead VDD pacing in intensive care
    Voigtlander, T
    Nowak, B
    Barenfanger, P
    Himmrich, E
    Treese, N
    Becker, HJ
    Meyer, J
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (10): : 1360 - 1363
  • [9] DDD and single-lead VDD pacing: Evaluation of atrial signal dynamic changes
    Boriani, G
    Biffi, M
    Bandini, A
    Moracchini, PV
    Capucci, A
    Sigliano, R
    Mininno, A
    Branzi, A
    CLINICAL CARDIOLOGY, 2000, 23 (09) : 678 - 680
  • [10] Atrial fibrillation incidence in patients with VDD single-lead and DDD pacing systems
    Moracchini, PV
    Tesorieri, MC
    Melandri, F
    Alfano, G
    Baraldi, P
    Zennaro, GR
    Corbucci, G
    EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 325 - 329