Safety and effectiveness of single-lead VDD pacing

被引:5
|
作者
Chabbar Boudet, Maruan C. [1 ]
Lukic, Antonella [1 ]
Galache Osuna, Jose G. [1 ]
de Juan Montiel, Jesus [1 ]
Cay Diarte, Eduardo [1 ]
Diarte de Miguel, Jose A. [1 ]
Peralta, Luis J. Placer [1 ]
机构
[1] Hosp Univ Miguel Servet, Unidad Marcapasos, Serv Cardiol, Zaragoza 50011, Spain
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2006年 / 59卷 / 09期
关键词
VDD pacing; atrioventricular block; atrial undersensing; supraventricular tachyarrhythmias; sinus node disease;
D O I
10.1157/13092797
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives. Single-lead VDD pacing provides the physiological benefits of atrioventricular synchrony with the convenience of a single-lead system. However, concern remains about the method's safety and effectiveness. Method. In total, 700 patients with single-lead VDD pacemakers were evaluated retrospectively. The following parameters were recorded: age, sex, etiology, the symptoms and electrocardiographic diagnosis that justified pacemaker implantation, the venous access route used for implantation, atrial sensing at implantation, atrial undersensing at follow-up, the occurrence of supraventricular tachyarrhythmias, and final pacing mode. Results. Third-degree atrioventricular block was the main indication for pacemaker implantation (66.4%). The most commonly used venous access route was via the right cephalic vein (49.1%). At implantation, the mean atrial signal was 1.8 (4 1.15) mV. During follow-up, significant atrial undersensing occurred in 7.7% of patients; in 1.9%, it could not be corrected by device reprogramming. Uncontrollable supraventricular arrhythmias were observed in 6.4% of patients. Symptomatic sinus node disease was rare. By the end of follow-up, 91.4% of patients were still on VDD pacing, while, in 8.3%, the pacemaker had to be reprogrammed to the VVI mode. Only 0.3% required atrial lead implantation for DDD pacing. Left-side venous access during implantation was a independent predictora of atrial undersensing at follow-up. Low values of atrial detection at implant did not reach statistical signification although it showed a remarkable trend. Conclusions. Single-lead VDD pacing seems to be safe and effective when appropriately indicated. Our findings are consistent with those of previously published studies.
引用
下载
收藏
页码:897 / 904
页数:8
相关论文
共 50 条
  • [31] Clinical results with single lead VDD pacing
    Liebold, A
    Merk, J
    Keyl, C
    Aebert, H
    Birnbaum, DE
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 (04) : 722 - 727
  • [32] Single lead VDD pacing: Multicenter study
    Ovsyshcher, IE
    Katz, A
    Rosenheck, S
    Erdman, S
    Bondy, C
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11): : 1768 - 1771
  • [33] Dual chamber pacing with a single lead VDD pacing system
    Rey, JL
    PACEMAKER LEADS 1997, 1997, : 169 - 172
  • [34] Diagnostic value of stored electrograms in single-lead VDD systems
    Israel, CW
    Gascon, D
    Nowak, B
    Campanale, G
    Pascotto, P
    Hartung, W
    Lellouche, D
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (11): : 1801 - 1803
  • [35] Dual chamber pacing with a single-lead DDD pacing system
    Naegeli, B
    Straumann, E
    Gerber, A
    Schuiki, E
    Kunz, M
    Niederhäuser, U
    Bertel, O
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (07): : 1013 - 1019
  • [36] Single lead atrial synchronised ventricular (VDD) pacing
    Crick, JCP
    PRACTICE AND PROGRESS IN CARDIAC PACING AND ELECTROPHYSIOLOGY, 1996, : 119 - 125
  • [37] Single pass lead VDD pacing in children and adolescents
    Rosenheck, S
    Elami, A
    Amikam, S
    Erdman, S
    Ovsyshcher, IE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (08): : 1961 - 1966
  • [38] VDD PACING WITH A PREVIOUSLY IMPLANTED SINGLE LEAD SYSTEM
    NAKATA, Y
    OGURA, S
    TOKANO, T
    YASUDA, M
    OHNO, Y
    HISAOKA, T
    SUMIYOSHI, M
    NAKAZATO, Y
    YAMAGUCHI, H
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (10): : 1425 - 1429
  • [39] Effectiveness of far-field-rejection in single-lead VDD stimulation depending on atrial dipole configuration
    Nowak, B
    Horstick, G
    Lorber, E
    Rippin, G
    Himmrich, E
    Meyer, J
    EUROPEAN HEART JOURNAL, 2000, 21 : 681 - 681
  • [40] A lower incidence of permanent atrial fibrillation in single-lead VDD versus two-lead DDD pacing in the treatment of AV block
    Nuemberg, M
    Hansen, S
    Steinbach, K
    CIRCULATION, 2002, 106 (19) : 624 - 625