SINGLE-LEAD VDD PACING SYSTEM

被引:41
|
作者
VARRIALE, P
PILLA, AG
TEKRIWAL, M
机构
[1] Division of Cardiology, Cabrini Medical Center, New York, New York
来源
关键词
atrial tracking; differential bipolar sensing; sensitivity threshold; single pass lead;
D O I
10.1111/j.1540-8159.1990.tb02102.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A single pass ventricular lead with a dual chamber electrode system, designed for VDD pacing, was implanted in 17 patients (11 men, 6 women, aged 53 to 86 years, mean 74) for symptomatic bradycardia due to second‐or third‐degree AV block and normal sinus node function. Bipolar atrial electrodes, diagonally displaced along the lead axis and positioned within the right atrial cavity, are used to detect atrial activity that is then differentially processed within the pacemaker, P wave amplitude (amp) derived from a PSA‐DAA device at implant was 1.38 ± 0.28 mV. P wave signal amp derived from telemetered atrial electrograms was 1,29 ± 0.22 mV at predischarge (n = 17), 1.32 ± 0.24 mV at 3 months (n = 15), 1.30 ± 0.24 mVat 6 months (n =8), 1.51 ± 0.34 mVat 9 months (n = 4), and 1.35 ± 0.35 mV at 12 months (n = 2); and the far‐field QRS signal measured at predischarge was of negligible voltage (0.17 ± 0.07 mV). The susceptibility of the atrial sensor system to interference was noted with chest wall stimulation and only at higher sensitivities (0.1 to 0.3 mV) and not with isometric arm exercise. Intact VDD pacing function at rest and during exercise was established using Holter and periodic ECG monitoring. Postoperative complications included one lead displacement and one pocket hematoma. Three patients died postimplant of causes unrelated to pacemaker function. Advantages of the single‐lead VDD pacing include: (1) elimination of second atrial sensing lead; (2) superior atrial sensing performance; (3) effective resistance to myopotential and far‐field signal interference; and (4) stability of postimplant atrial signal amplitude. Copyright © 1990, Wiley Blackwell. All rights reserved
引用
下载
收藏
页码:757 / 766
页数:10
相关论文
共 50 条
  • [1] Single-lead VDD/DDD pacing
    Ovsyshcher, IE
    Wagshal, AB
    CARDIAC ARRHYTHMIAS, PACING & ELECTROPHYSIOLOGY: THE EXPERT VIEW, 1998, 201 : 389 - 398
  • [2] SINGLE-LEAD VDD PACING - EXCELLENCE OR EXPEDIENCE
    KATRITSIS, D
    CAMM, AJ
    CLINICAL CARDIOLOGY, 1991, 14 (11) : 917 - 922
  • [3] Safety and effectiveness of single-lead VDD pacing
    Chabbar Boudet, Maruan C.
    Lukic, Antonella
    Galache Osuna, Jose G.
    de Juan Montiel, Jesus
    Cay Diarte, Eduardo
    Diarte de Miguel, Jose A.
    Peralta, Luis J. Placer
    REVISTA ESPANOLA DE CARDIOLOGIA, 2006, 59 (09): : 897 - 904
  • [4] SINGLE-LEAD FOR PERMANENT VDD PACING IN SELECTED PATIENTS
    ANTONIOLI, GE
    SERMASI, S
    MARZALONI, M
    RUSCONI, L
    PERCOCO, GF
    TOSELLI, T
    BAGGIONI, GF
    POZZAR, C
    FERRARI, C
    ROSSI, F
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (04): : 496 - 496
  • [5] Dual-Chamber Stimulation with Single-Lead VDD Pacing System in Mustard Surgery
    Michel Cabrera-Ortega
    Francisco Díaz-Ramírez
    Dunia B. Benítez-Ramos
    Pediatric Cardiology, 2015, 36 : 1301 - 1303
  • [6] Dual-Chamber Stimulation with Single-Lead VDD Pacing System in Mustard Surgery
    Cabrera-Ortega, Michel
    Diaz-Ramirez, Francisco
    Benitez-Ramos, Dunia B.
    PEDIATRIC CARDIOLOGY, 2015, 36 (06) : 1301 - 1303
  • [7] Atrial sensing performance of a single-lead VDD pacing system during physical activities
    Ertas, F
    Karaoguz, R
    Güldal, M
    Kumbasar, D
    Güleç, S
    Oral, D
    JOURNAL OF ELECTROCARDIOLOGY, 2000, 33 (03) : 253 - 260
  • [8] Reliability of single-lead VDD atrial sensing and pacing during exercise
    Guyomar, Y
    Graux, P
    Carlioz, R
    Moulin, C
    Dutoit, A
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (12): : 1747 - 1752
  • [9] Single-lead VDD-pacing system incorporating high impedance stimulation: a multicentre study
    Nowak, B
    Israel, CW
    Gascon, D
    Knops, M
    Campanale, G
    Lellouche, D
    Hartung, W
    Pascotto, R
    Manolis, A
    Blanc, P
    Martinez, JG
    Timmermans, AJM
    EUROPACE, 2002, 4 (02): : 129 - 135
  • [10] A NEW SINGLE LEAD VDD PACING SYSTEM
    PERCOCO, GF
    ANSANI, L
    BARBIERI, D
    GUARDIGLI, G
    TOSELLI, T
    AUDOGLIO, R
    ANTONIOLI, GE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (12): : 1906 - 1909