SINGLE-LEAD VDD PACING SYSTEM

被引:41
|
作者
VARRIALE, P
PILLA, AG
TEKRIWAL, M
机构
[1] Division of Cardiology, Cabrini Medical Center, New York, New York
来源
关键词
atrial tracking; differential bipolar sensing; sensitivity threshold; single pass lead;
D O I
10.1111/j.1540-8159.1990.tb02102.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A single pass ventricular lead with a dual chamber electrode system, designed for VDD pacing, was implanted in 17 patients (11 men, 6 women, aged 53 to 86 years, mean 74) for symptomatic bradycardia due to second‐or third‐degree AV block and normal sinus node function. Bipolar atrial electrodes, diagonally displaced along the lead axis and positioned within the right atrial cavity, are used to detect atrial activity that is then differentially processed within the pacemaker, P wave amplitude (amp) derived from a PSA‐DAA device at implant was 1.38 ± 0.28 mV. P wave signal amp derived from telemetered atrial electrograms was 1,29 ± 0.22 mV at predischarge (n = 17), 1.32 ± 0.24 mV at 3 months (n = 15), 1.30 ± 0.24 mVat 6 months (n =8), 1.51 ± 0.34 mVat 9 months (n = 4), and 1.35 ± 0.35 mV at 12 months (n = 2); and the far‐field QRS signal measured at predischarge was of negligible voltage (0.17 ± 0.07 mV). The susceptibility of the atrial sensor system to interference was noted with chest wall stimulation and only at higher sensitivities (0.1 to 0.3 mV) and not with isometric arm exercise. Intact VDD pacing function at rest and during exercise was established using Holter and periodic ECG monitoring. Postoperative complications included one lead displacement and one pocket hematoma. Three patients died postimplant of causes unrelated to pacemaker function. Advantages of the single‐lead VDD pacing include: (1) elimination of second atrial sensing lead; (2) superior atrial sensing performance; (3) effective resistance to myopotential and far‐field signal interference; and (4) stability of postimplant atrial signal amplitude. Copyright © 1990, Wiley Blackwell. All rights reserved
引用
收藏
页码:757 / 766
页数:10
相关论文
共 50 条
  • [41] A lower incidence of permanent atrial fibrillation in single-lead VDD versus two-lead DDD pacing in the treatment of AV block
    Nuemberg, M
    Hansen, S
    Steinbach, K
    CIRCULATION, 2002, 106 (19) : 624 - 625
  • [42] Optimal side of implant for single-lead VDD pacing: Right-sided versus left-sided implantation
    Haghjoo, M
    Arya, A
    Emkanjoo, Z
    Sadr-Ameli, MA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (05): : 384 - 390
  • [43] Clinical reliability of single-lead VDD pacing from evaluation of P-wave sensing under dynamic conditions
    Boriani, G
    Biffi, M
    Bandini, A
    Pettini, A
    Moracchini, PV
    Giuliani, M
    Capucci, A
    Groppi, F
    Sigliano, R
    Mininno, A
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (05): : 676 - +
  • [44] The long term efficacy of physiologic pacing in children and adults with single pass lead VDD pacing system
    Rosenheck, S
    Weiss, A
    Leibowitz, D
    Sharon, Z
    NEW TRENDS IN ELECTROCARDIOLOGY, 2000, : 161 - 166
  • [45] Immediate and long-term atrial sensing stability in single-lead VDD pacing depends on right atrial dimensions
    Santini, M
    Ricci, R
    Pignalberi, C
    Auriti, A
    Pepe, M
    Assale, R
    Caporicci, D
    EUROPACE, 2001, 3 (04): : 324 - 331
  • [46] First experience with an automatic sensing algorithm in single-lead VDD stimulation
    Nowak, B
    Fellmann, P
    Maertens, S
    Mols, R
    Demetz, K
    Brüls, A
    Geil, S
    Voigtländer, T
    Himmrich, E
    Meyer, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11): : 2232 - 2235
  • [47] Outcomes of single-lead VDD pacemakers in atrioventricular blocks: The OSCAR study
    Sanna, Giuseppe D.
    Nusdeo, Giuseppe
    Marini, Alessandro
    Ganga, Maria Luisa
    Mura, Enrico
    Pisano, Mauro
    Sabino, Giuseppe
    Parodi, Guido
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 325 : 62 - 68
  • [48] ATRIAL SENSING PERFORMANCE OF THE SINGLE-LEAD VDD PACEMAKER DURING EXERCISE
    VARRIALE, P
    CHRYSSOS, BE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (07) : 1854 - 1857
  • [49] Determinants of atrial sensing in VDD single-lead systems [Determinanten des atrialen sensings bei VDD-single-lead-systemen]
    Israel C.W.
    Herzschrittmachertherapie und Elektrophysiologie, 1998, 9 (4): : 234 - 247
  • [50] Atrial perception and AV synchronicity in single-lead VDD pacemakers - Reply
    Wiegand, UKH
    ZEITSCHRIFT FUR KARDIOLOGIE, 1997, 86 (08): : 651 - 651