Implantation of a dual chamber pacing and sensing single pass defibrillation lead

被引:5
|
作者
Gradaus, R [1 ]
Block, M
Dorszewski, A
Schriever, C
Hammel, D
Scheld, HH
Borggrefe, M
Breithardt, G
Böcker, D
机构
[1] Univ Munster, Med Klin & Poliklin, Dept Cardiol & Angiol, D-48129 Munster, Germany
[2] Univ Munster, Inst Arteriosclerosis Res, D-48129 Munster, Germany
[3] Dept Cardiovasc Surg, Munster, Germany
来源
关键词
implantable defibrillator; defibrillation lead; atrial and ventricular sensing and pacing;
D O I
10.1046/j.1460-9592.2001.00416.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dual-chamber ICDs are increasingly used to avoid inappropriate shocks due to supraventricular tachycardios. Additionally, many ICD patients will probably benefit from dual chamber pacing. The purpose of this pilot study was to evaluate the intraoperative performance and short-term follow-up of an innovative single pass right ventricular defibrillation lead capable of bipolar sensing and pacing in the right atrium and ventricle. implantation of this single pass right ventricular defibrillation lead was successful in all 13 patients (age 63 +/- 8 years; LVEF 0.44 +/- 0.26; New York Heart Association [NYHA] 2.4 +/- 0.4, previous open heart surgery in all patients). The operation time was 79 +/- 29 minutes, the fluoroscopy time 4.7 +/- 3.2 minutes. No perioperative complications occurred. The intraoperative atrial sensing was 1.7 +/- 0.5 mV the artrial pacing threshold product was 0.20 +/- 0.14 V/ms (range 0.03-0.50 V/ms). The defibrillation threshold was 8.8 +/- 2.7 J. At prehospital discharge and at I-month and 3-month follow-up, atrial sensing was 1.9 +/- 0.9, 2.1 +/- 0.5, and 2.7 +/- 0.6 mV respectively, (P = NS, P < 0.05, P < 0.05 to implant, respectively), the mean atrial threshold product 0.79, 1.65, and 1.29 V/ms, respectively. In two patients, an intermittent exit block occurred in different body postures. All spontaneous and induced ventricular arrhythmias were defected and terminated appropriately. Thus, in a highly selected patient group, atrial and ventricular sensing and pacing with a single lead is possible under consideration of an atrial pacing dysfunction in 17% of patients.
引用
收藏
页码:416 / 423
页数:8
相关论文
共 50 条
  • [1] European clinical experience with a dual chamber single pass sensing and pacing defibrillation lead
    Gradaus, R
    Gonska, BD
    Stellbrink, C
    Cron, T
    Tebbenjohanns, J
    Blomström-Lundqvist, C
    Himmrich, E
    Salerno, JA
    Osswald, S
    Gommer, ED
    Van Veen, BK
    Böcker, D
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (07): : 1079 - 1086
  • [2] The current status of single lead dual chamber sensing and pacing
    Tse, HF
    Lau, CP
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1998, 2 (03) : 255 - 267
  • [3] The Current Status of Single Lead Dual Chamber Sensing and Pacing
    Hung-Fat Tse
    Chu-Pak Lau
    [J]. Journal of Interventional Cardiac Electrophysiology, 1998, 2 : 255 - 267
  • [4] Dual chamber single lead pacing
    Osswald, S
    Naegeli, B
    [J]. HEART, 1998, 79 (03) : 217 - 218
  • [5] Dual chamber cardiac pacing in children:: Single chamber pacing dual chamber sensing cardiac pacemaker or dual chamber pacing and sensing cardiac pacemaker?
    Bostan, ÖM
    Çeliker, A
    Karagöz, T
    Özer, S
    Özme, S
    [J]. PEDIATRICS INTERNATIONAL, 2002, 44 (06) : 635 - 640
  • [6] Feasibility of Atrial Sensing Via a Free-Floating Single-Pass Defibrillation Lead for Dual-Chamber Defibrillators
    Andreas Schuchert
    Michael Niehaus
    Ludwig Binner
    Roberto Belke
    Thomas Meinertz
    [J]. Journal of Interventional Cardiac Electrophysiology, 2003, 8 : 209 - 214
  • [7] Feasibility of atrial sensing via a free-floating single-pass defibrillation lead for dual-chamber defibrillators
    Schuchert, A
    Niehaus, M
    Binner, L
    Belke, R
    Meinertz, T
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2003, 8 (03) : 209 - 214
  • [8] Single lead dual-chamber pacing
    Mitchell, I
    McKenzie, T
    Nikolic, G
    [J]. HEART & LUNG, 2003, 32 (02): : 144 - 145
  • [9] Dual chamber pacing with a single lead VDD pacing system
    Rey, JL
    [J]. PACEMAKER LEADS 1997, 1997, : 169 - 172
  • [10] Atrial sensing and pacing with a single pass ventricular lead
    Tse, HF
    Lau, CP
    [J]. CHINESE MEDICAL JOURNAL, 1998, 111 (12) : 1118 - 1123