Implantation of a dual chamber pacing and sensing single pass defibrillation lead

被引:5
|
作者
Gradaus, R [1 ]
Block, M
Dorszewski, A
Schriever, C
Hammel, D
Scheld, HH
Borggrefe, M
Breithardt, G
Böcker, D
机构
[1] Univ Munster, Med Klin & Poliklin, Dept Cardiol & Angiol, D-48129 Munster, Germany
[2] Univ Munster, Inst Arteriosclerosis Res, D-48129 Munster, Germany
[3] Dept Cardiovasc Surg, Munster, Germany
来源
关键词
implantable defibrillator; defibrillation lead; atrial and ventricular sensing and pacing;
D O I
10.1046/j.1460-9592.2001.00416.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dual-chamber ICDs are increasingly used to avoid inappropriate shocks due to supraventricular tachycardios. Additionally, many ICD patients will probably benefit from dual chamber pacing. The purpose of this pilot study was to evaluate the intraoperative performance and short-term follow-up of an innovative single pass right ventricular defibrillation lead capable of bipolar sensing and pacing in the right atrium and ventricle. implantation of this single pass right ventricular defibrillation lead was successful in all 13 patients (age 63 +/- 8 years; LVEF 0.44 +/- 0.26; New York Heart Association [NYHA] 2.4 +/- 0.4, previous open heart surgery in all patients). The operation time was 79 +/- 29 minutes, the fluoroscopy time 4.7 +/- 3.2 minutes. No perioperative complications occurred. The intraoperative atrial sensing was 1.7 +/- 0.5 mV the artrial pacing threshold product was 0.20 +/- 0.14 V/ms (range 0.03-0.50 V/ms). The defibrillation threshold was 8.8 +/- 2.7 J. At prehospital discharge and at I-month and 3-month follow-up, atrial sensing was 1.9 +/- 0.9, 2.1 +/- 0.5, and 2.7 +/- 0.6 mV respectively, (P = NS, P < 0.05, P < 0.05 to implant, respectively), the mean atrial threshold product 0.79, 1.65, and 1.29 V/ms, respectively. In two patients, an intermittent exit block occurred in different body postures. All spontaneous and induced ventricular arrhythmias were defected and terminated appropriately. Thus, in a highly selected patient group, atrial and ventricular sensing and pacing with a single lead is possible under consideration of an atrial pacing dysfunction in 17% of patients.
引用
收藏
页码:416 / 423
页数:8
相关论文
共 50 条
  • [21] Clinical evaluation of a prototype passive fixation dual chamber single pass lead for dual chamber ICD systems
    Butter, C
    Auricchio, A
    Schwarz, T
    Fleck, E
    Schubert, B
    Hsu, W
    Michel, U
    Neuzner, J
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (01): : 169 - 173
  • [22] Clinical experience with a single-pass lead for dual-chamber ICDs
    Böcker, D
    Gradaus, R
    Osswald, S
    Cron, T
    Gommer, ED
    [J]. EUROPEAN HEART JOURNAL, 2000, 21 : 470 - 470
  • [23] Neuroendocrine and haemodynamic changes in single-lead atrial pacing and dual-chamber pacing modes
    Zhang, Ying-ying
    Wu, Dong-yan
    Fu, Nai-kuan
    Lu, Feng-min
    Xu, Jing
    [J]. JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2013, 41 (04) : 1057 - 1066
  • [24] A comparison of single-lead atrial pacing with dual-chamber pacing in sick sinus syndrome
    Nielsen, Jens Cosedis
    Thomsen, Poul Erik B.
    Hojberg, Soren
    Moller, Mogens
    Vesterlund, Thomas
    Dalsgaard, Dorthe
    Mortensen, Leif S.
    Nielsen, Tonny
    Asklund, Mogens
    Friis, Elsebeth V.
    Christensen, Per D.
    Simonsen, Erik H.
    Eriksen, Ulrik H.
    Jensen, Gunnar V. H.
    Svendsen, Jesper H.
    Toff, William D.
    Healey, Jeffrey S.
    Andersen, Henning R.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 (06) : 686 - 696
  • [25] Single chamber ventricular compared with dual chamber pacing: A review
    Wong, GC
    Hadjis, T
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2002, 18 (03) : 301 - 307
  • [26] EXPERIENCE WITH A SINGLE-PASS ATRIAL DEFIBRILLATION LEAD SYSTEM
    AYERS, GM
    TACKER, WA
    GONZALEZ, X
    SCHOENLEIN, WE
    JANAS, WT
    ALTERNESS, CA
    [J]. CIRCULATION, 1995, 92 (08) : 2256 - 2256
  • [27] PACEMAKERS - DUAL OR SINGLE CHAMBER IMPLANTATION
    MAYER, DA
    TSAPOGAS, MJ
    [J]. VASCULAR SURGERY, 1992, 26 (05): : 400 - 407
  • [28] Single pass lead VDD pacing in children and adolescents
    Rosenheck, S
    Elami, A
    Amikam, S
    Erdman, S
    Ovsyshcher, IE
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (08): : 1961 - 1966
  • [29] Dual-Chamber Stimulation with Single-Lead VDD Pacing System in Mustard Surgery
    Cabrera-Ortega, Michel
    Diaz-Ramirez, Francisco
    Benitez-Ramos, Dunia B.
    [J]. PEDIATRIC CARDIOLOGY, 2015, 36 (06) : 1301 - 1303
  • [30] Long-term complication rates in ventricular, single lead VDD, and dual chamber pacing
    Wiegand, UKH
    Bode, F
    Bonnemeier, H
    Eberhard, F
    Schlei, M
    Peters, W
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (10): : 1961 - 1969