Dual chamber pacing with a single-lead DDD pacing system

被引:4
|
作者
Naegeli, B [1 ]
Straumann, E
Gerber, A
Schuiki, E
Kunz, M
Niederhäuser, U
Bertel, O
机构
[1] Stadtspital Triemli, Dept Internal Med, Cardiac Unit, CH-8063 Zurich, Switzerland
[2] Stadtspital Triemli, Dept Cardiac Surg, CH-8063 Zurich, Switzerland
来源
关键词
DDD pacing; single lead;
D O I
10.1111/j.1540-8159.1999.tb00565.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The successful application of single-lead VDD pacing during the last few years hers generated the idea of single-lead DDD pacing: Preliminary data from several single-lead VDD studies attempting to pace the atrium by a floating atrial dipole are unsatisfactory, causing an unacceptably high current drain of the device. We studied thefeasibility as well as the short- and long-term stability of atrioventricular sequential pacing, using a new single-pass, tined DDD lead. In eight consecutive patients (age 73 +/- 16 years) with symptomatic higher degree A V block and intact sinus node function, this new single-pass DDD lead was implanted in combination with a. DDDR pacemaker. Correct VDD and DDD function wets studied at implantation; at discharge; and at 1, 3, and 6 months of follow-up. At implant, the atrial stimulation threshold was 0.6 +/- 0.2 V/0.5 ms. During follow-up, the atrial pacing thresholds in different everyday positions averaged 2.1 +/- 0.5 V at discharge, 2.9 +/- 0.5 V at 2 month, 3.8 +/- 0.4 V at 3 months, and 3.4 +/- 0.4 V at 6 months (pulse width always 0.5 ms). The measured P wave amplitude at implantation was 4.5 +/- 2.2 mV; during follow-up the telemetered atrial sensitivity thresholds averaged 2.2 +/- 0.3 mV. Phrenic nerve stimulation at high output pacing (5.0 V/0.5 ms) was observed in three (38%) patients at discharge and in one (13%) patient during follow-up; an intermittent unmeasurable atrial lead impedance at 3 and 6 months follow-up was documented in one (13%) patient. This study confirms the possibility of short- and long-term DDD pacing using a single-pass DDD lead. Since atrial stimulation thresholds are still relatively high compared to conventional dual-lead DDD pacing, further improvements of the atrial electrodes are desirable, enabling lower pacing thresholds and optimizing energy requirements as well as minimizing the potential disadvantage of phrenic nerve stimulation.
引用
收藏
页码:1013 / 1019
页数:7
相关论文
共 50 条
  • [41] Atrial sensing performance of a single-lead VDD pacing system during physical activities
    Ertas, F
    Karaoguz, R
    Güldal, M
    Kumbasar, D
    Güleç, S
    Oral, D
    JOURNAL OF ELECTROCARDIOLOGY, 2000, 33 (03) : 253 - 260
  • [42] A lower incidence of permanent atrial fibrillation in single-lead VDD versus two-lead DDD pacing in the treatment of AV block
    Nuemberg, M
    Hansen, S
    Steinbach, K
    CIRCULATION, 2002, 106 (19) : 624 - 625
  • [43] Single chamber ventricular compared with dual chamber pacing: A review
    Wong, GC
    Hadjis, T
    CANADIAN JOURNAL OF CARDIOLOGY, 2002, 18 (03) : 301 - 307
  • [44] LATE CONVERSION FROM A SINGLE TO A DUAL CHAMBER PACING SYSTEM IN DDD MODE OF PATIENTS WITH CONGENITAL OR POSTSURGICAL HEART-BLOCK
    MOLINA, JE
    TUNA, N
    DUNNIGAN, A
    BENDITT, DG
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (05): : 1221 - 1221
  • [45] A multicenter experience on chronic single-pass lead DDD pacing
    Bongiorni, M
    DiGregorio, F
    Moracchini, PV
    Nava, A
    Caprioli, E
    Gascon, D
    PACEMAKER LEADS 1997, 1997, : 187 - 191
  • [46] Feasibility of dual-chamber (DDD) pacing via a single-pass (VDD) pacing lead employing a floating atrial ring (dipole): Case series, future considerations, and refinements
    Kassotis, J
    Voigt, L
    Mongwa, M
    Reddy, CVR
    ANGIOLOGY, 2005, 56 (03) : 323 - 329
  • [47] CARDIAC-OUTPUT IN SINGLE-LEAD VDD PACING VERSUS RATE-MATCHED VVIR PACING
    NOWAK, B
    VOIGTLANDER, T
    HIMMRICH, E
    LIEBRICH, A
    POSCHMANN, G
    EPPERLEIN, S
    TREESE, N
    MEYER, J
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (14): : 904 - 907
  • [48] Single-lead VDD pacing-a serious alternative for atrioventricular synchronous pacing in patients with atrioventricular block?
    Wiegand, Uwe K. H.
    EUROPACE, 2012, 14 (04): : 461 - 462
  • [49] DUAL CHAMBER SEQUENTIAL PACING MANAGEMENT OF SINUS NODE DYSFUNCTION - ADVANTAGES OVER SINGLE CHAMBER PACING
    STONE, JM
    BHAKTA, RD
    LUTGEN, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1981, 4 (03): : A76 - A76
  • [50] Single lead DDD pacing using the new OLBI stimulation method
    Bodnar, J
    VI ASIAN-PACIFIC SYMPOSIUM ON CARDIAC PACING AND ELECTROPHYSIOLOGY, 1997, : 105 - 109