Reliability and Validity of Non-invasive Blood Pressure Measurement System Using Three-Axis Tactile Force Sensor

被引:12
|
作者
Yoo, Sun-Young [1 ]
Ahn, Ji-Eun [2 ]
Cserey, Gyoergy [3 ]
Lee, Hae-Young [4 ,5 ]
Seo, Jong-Mo [1 ,5 ]
机构
[1] Seoul Natl Univ, Inst Engn Res, Interuniv Semicond Res Ctr, Dept Elect & Comp Engn, Seoul 08826, South Korea
[2] Seoul Natl Univ, Interdisciplinary Program Bioengn, Seoul 03080, South Korea
[3] Pazmany Peter Catholic Univ, Fac Informat Technol & Bion, H-1083 Budapest, Hungary
[4] Seoul Natl Univ Hosp, Dept Internal Med, Seoul 03080, South Korea
[5] Seoul Natl Univ Hosp, Biomed Res Inst, Seoul 03080, South Korea
来源
SENSORS | 2019年 / 19卷 / 07期
关键词
non-invasive blood pressure measurement; radial arterial pressure; continuous blood pressure monitoring; three-axis tactile force sensor; ARTERY APPLANATION TONOMETRY; STATISTICAL-METHODS; VALIDATION; AGREEMENT;
D O I
10.3390/s19071744
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Blood pressure (BP) is a physiological parameter reflecting hemodynamic factors and is crucial in evaluating cardiovascular disease and its prognosis. In the present study, the reliability of a non-invasive and continuous BP measurement using a three-axis tactile force sensor was verified. All the data were collected every 2 min for the short-term experiment, and every 10 min for the long-term experiment. In addition, the effects on the BP measurement of external physical factors such as the tension to the radial artery on applying the device and wrist circumference were evaluated. A high correlation between the measured BP with the proposed system and with the cuff-based non-invasive blood pressure, and reproducibility, were demonstrated. All data satisfied the Association for the Advancement of Medical Instrumentation criteria. The external physical factors did not affect the measurement results. In addition to previous research indicating the high reliability of the arterial pulse waveforms, the present results have demonstrated the reliability of numerical BP values, and this implies that the three-axis force sensor can be used as a patient monitoring device.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Non-Invasive Blood Pressure Measurement Using A Mobile Phone Camera
    Zhang, Yuxuan
    Zhang, Xiao
    Du, Jinlian
    2022 IEEE CONFERENCE ON COMPUTATIONAL INTELLIGENCE IN BIOINFORMATICS AND COMPUTATIONAL BIOLOGY (IEEE CIBCB 2022), 2022, : 11 - 16
  • [22] Reliability of non-invasive arterial blood pressure measurement in patients with aneurysmal subarachnoid haemorrhage
    Olsen, Markus Harboe
    Riberholt, Christian Gunge
    Capion, Tenna
    Berg, Ronan M. G.
    Moller, Kirsten
    PHYSIOLOGICAL MEASUREMENT, 2022, 43 (07)
  • [23] Soft capacitive tactile sensing array with high-robustness for three-axis pressure measurement
    Yu, Jianping
    Yao, Shengjie
    Li, Xin
    Ghaffar, Abdul
    Zhang, Yuanxiang
    Jiang, Xiaoliang
    Lin, Huan
    Yao, Zhehe
    MEASUREMENT, 2023, 223
  • [24] Ophthalmic Artery as a Sensor for Non-invasive Intracranial Pressure Measurement Electronic System
    Bartusis, L.
    Zakelis, R.
    Daubaris, G.
    Ragauskas, A.
    Rutkauskas, S.
    Matijosaitis, V.
    Preiksaitis, A.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2012, 122 (06) : 45 - 48
  • [25] Design and Implementation of Non-invasive Continuous Blood Pressure Measurement and Monitoring System Using Photoplethysmography
    Islam, Md. Aminul
    Ahmad, Mohiuddin
    2018 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (ICECE), 2018, : 173 - 176
  • [26] Non-invasive Blood Glucose Measurement System
    Deepthi, S.
    Valke, Nikita S.
    Parvathy, J. P.
    Sai, Anjaly Krishna
    Sajjan, Guttappa
    2019 5TH IEEE INTERNATIONAL WIE CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (WIECON-ECE 2019), 2019,
  • [27] A wearable three-axis force sensor based on deep learning technology for plantar measurement
    Zhang, Qi
    Zhao, Yang
    Qian, Zhengfang
    Liu, Zhiyuan
    Wang, Renheng
    CHEMICAL ENGINEERING JOURNAL, 2024, 482
  • [28] Non-invasive blood pressure measurement in dogs and cats
    Mandigers, P
    TIJDSCHRIFT VOOR DIERGENEESKUNDE, 2005, 130 (07) : 198 - 201
  • [29] Advances in Non-Invasive Blood Pressure Measurement Techniques
    Panula, Tuukka
    Sirkia, Jukka-Pekka
    Wong, David
    Kaisti, Matti
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2023, 16 : 424 - 438
  • [30] Non-invasive measurement of rapid blood pressure changes
    Raamat, R
    Toska, K
    Jagomägi, K
    Talts, J
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 889 - 892