Ophthalmic Artery as a Sensor for Non-invasive Intracranial Pressure Measurement Electronic System

被引:2
|
作者
Bartusis, L. [1 ]
Zakelis, R. [1 ]
Daubaris, G. [1 ]
Ragauskas, A. [1 ]
Rutkauskas, S. [2 ]
Matijosaitis, V. [3 ]
Preiksaitis, A. [4 ]
机构
[1] Kaunas Univ Technol, Telemat Sci Lab, LT-51368 Kaunas, Lithuania
[2] Hosp Lithuanian Univ, Hlth Sci Kaunas Clin, Dept Radiol, LT-50009 Kaunas, Lithuania
[3] Hosp Lithuanian Univ, Hlth Sci Kaunas Clin, Dept Neurol, LT-50009 Kaunas, Lithuania
[4] Vilnius State Univ, Fac Med, Dept Neurol & Neurosurg, LT-04130 Vilnius, Lithuania
关键词
D O I
10.5755/j01.eee.122.6.1194
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
L. Bartusis, R. Zakelis, G. Daubaris, A. Ragauskas, S. Rutkauskas, V. Matijosaitis, A. Preiksaitis. Ophthalmic Artery as a Sensor for Non-invasive Intracranial Pressure Measurement Electronic System // Electronics and Electrical Engineering. - Kaunas: Technologija, 2012. - No. 6(122). - P. 45-48. Theoretical and experimental validity of ophthalmic artery (OA) as a sensor for non-invasive absolute intracranial pressure (aICP) measurement electronic system is presented in this paper. Because of OA similarity with gravimetric scales which can compare aICP with non-invasively applied external pressure Pe the value of aICP can be measured without the need of patient specific calibration. For the indication of aICP and Pe balance various blood flow parameters existing in intracranial and extracranial segments of OA are used. Pressure balance ICP=Pe occurs in the case of maximum conjunction of various blood flow parameters in intracranial and extracranial segments respectively. For the measurement of the blood flow parameters and indication of aICP specially designed hardware and software has been created in Telematics Scientific Laboratory of Kaunas University of Technology. The software of non-invasive aICP meter was developed concerning the fast location of IOA and EOA and fully automatic aICP measurement process. Prospective comparative clinical studies of 84 neurological patients were performed in order to test performance of created system in clinical conditions and to validate ophthalmic artery performance as non-invasive aICP sensor. Ill. 3, bibl. 13 (in English; abstracts in English and Lithuanian).
引用
收藏
页码:45 / 48
页数:4
相关论文
共 50 条
  • [1] Non-invasive measurement of intracranial pressure
    Hartmann, A
    LANCET, 1998, 351 (9101): : 524 - 524
  • [2] Human ophthalmic artery as a sensor for non-invasive intracranial pressure monitoring: numerical modeling and in vivo pilot study
    Lucinskas, Paulius
    Deimantavicius, Mantas
    Bartusis, Laimonas
    Zakelis, Rolandas
    Misiulis, Edgaras
    Dziugys, Algis
    Hamarat, Yasin
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [3] Human ophthalmic artery as a sensor for non-invasive intracranial pressure monitoring: numerical modeling and in vivo pilot study
    Paulius Lucinskas
    Mantas Deimantavicius
    Laimonas Bartusis
    Rolandas Zakelis
    Edgaras Misiulis
    Algis Dziugys
    Yasin Hamarat
    Scientific Reports, 11
  • [4] DEVELOPMENT OF A SENSOR FOR NON-INVASIVE INTRACRANIAL-PRESSURE MEASUREMENT IN THE NEWBORN
    BURTON, PJ
    ROCHEFORT, M
    ROLFE, P
    GODDARD, PJ
    JOURNAL OF BIOMEDICAL ENGINEERING, 1988, 10 (02): : 171 - 174
  • [5] Location of the internal carotid artery and ophthalmic artery segments for non-invasive intracranial pressure measurement by multi-depth TCD
    Hamarat, Yasin
    Deimantavicius, Mantas
    Kalvaitis, Evaldas
    Siaudvytyte, Lina
    Januleviciene, Ingrida
    Zakelis, Rolandas
    Bartusis, Laimonas
    LIBYAN JOURNAL OF MEDICINE, 2017, 12
  • [6] Accuracy of non-invasive intracranial pressure measurement
    Seddighi, Amir Saied
    Zadeh, Alireza Moqareh
    Seddighi, Afsoun
    Zali, Alireza
    CENTRAL EUROPEAN JOURNAL OF MEDICINE, 2012, 7 (02): : 169 - 175
  • [7] Non-invasive technologies for intracranial pressure/volume measurement
    Ragauskas, A
    Petkus, V
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 259 - 262
  • [8] Non-invasive Biomedical Patch Sensor to Measure Intracranial Pressure
    Griffith, Jacob L.
    Wakim, Andre' A.
    Moore-Jansen, Peer
    Cluff, Kim
    2016 IEEE 13TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2016, : 211 - 211
  • [9] Transcranial Bioimpedance Measurement as a Non-invasive Estimate of Intracranial Pressure
    Hawthorne, Christopher
    Shaw, Martin
    Piper, Ian
    Moss, Laura
    Kinsella, John
    INTRACRANIAL PRESSURE & NEUROMONITORING XVI, 2018, 126 : 89 - 92
  • [10] In Vitro Evaluation of a Non-Invasive Photoplethysmography Based Intracranial Pressure Sensor
    Abay, Tomas Y. Y.
    Phillips, Justin P. P.
    Uff, Christopher
    Roldan, Maria
    Kyriacou, Panicos A. A.
    APPLIED SCIENCES-BASEL, 2023, 13 (01):