Ophthalmic Artery as a Sensor for Non-invasive Intracranial Pressure Measurement Electronic System

被引:2
|
作者
Bartusis, L. [1 ]
Zakelis, R. [1 ]
Daubaris, G. [1 ]
Ragauskas, A. [1 ]
Rutkauskas, S. [2 ]
Matijosaitis, V. [3 ]
Preiksaitis, A. [4 ]
机构
[1] Kaunas Univ Technol, Telemat Sci Lab, LT-51368 Kaunas, Lithuania
[2] Hosp Lithuanian Univ, Hlth Sci Kaunas Clin, Dept Radiol, LT-50009 Kaunas, Lithuania
[3] Hosp Lithuanian Univ, Hlth Sci Kaunas Clin, Dept Neurol, LT-50009 Kaunas, Lithuania
[4] Vilnius State Univ, Fac Med, Dept Neurol & Neurosurg, LT-04130 Vilnius, Lithuania
关键词
D O I
10.5755/j01.eee.122.6.1194
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
L. Bartusis, R. Zakelis, G. Daubaris, A. Ragauskas, S. Rutkauskas, V. Matijosaitis, A. Preiksaitis. Ophthalmic Artery as a Sensor for Non-invasive Intracranial Pressure Measurement Electronic System // Electronics and Electrical Engineering. - Kaunas: Technologija, 2012. - No. 6(122). - P. 45-48. Theoretical and experimental validity of ophthalmic artery (OA) as a sensor for non-invasive absolute intracranial pressure (aICP) measurement electronic system is presented in this paper. Because of OA similarity with gravimetric scales which can compare aICP with non-invasively applied external pressure Pe the value of aICP can be measured without the need of patient specific calibration. For the indication of aICP and Pe balance various blood flow parameters existing in intracranial and extracranial segments of OA are used. Pressure balance ICP=Pe occurs in the case of maximum conjunction of various blood flow parameters in intracranial and extracranial segments respectively. For the measurement of the blood flow parameters and indication of aICP specially designed hardware and software has been created in Telematics Scientific Laboratory of Kaunas University of Technology. The software of non-invasive aICP meter was developed concerning the fast location of IOA and EOA and fully automatic aICP measurement process. Prospective comparative clinical studies of 84 neurological patients were performed in order to test performance of created system in clinical conditions and to validate ophthalmic artery performance as non-invasive aICP sensor. Ill. 3, bibl. 13 (in English; abstracts in English and Lithuanian).
引用
收藏
页码:45 / 48
页数:4
相关论文
共 50 条
  • [41] Development of a non-invasive measurement system for the pressure of esophageal varices
    Ma, ZM
    Kwok, LS
    Guan, YC
    1ST ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2000, : 127 - 129
  • [42] Non-invasive Measurement of Portal Pressure
    Elmahdy A.M.
    Berzigotti A.
    Current Hepatology Reports, 2019, 18 (1) : 20 - 27
  • [43] Velocity measurement using MEMS ultrasonic sensor for non-invasive blood pressure measurement
    Takei Y.
    Matsui R.
    Minh-Dung N.
    Takahata T.
    Matsumoto K.
    Shimoyama I.
    IEEJ Transactions on Sensors and Micromachines, 2018, 138 (02) : 54 - 58
  • [44] Measurement of Blood Pressure via a Skin-Mounted, Non-Invasive Pressure Sensor
    Li, Shupeng
    Park, Yoonseok
    Luan, Haiwen
    Wang, Heling
    Kwon, Kyeongha
    Rogers, John A.
    Huang, Yonggang
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 2021, 88 (10):
  • [45] Non-invasive measurement of intracranial compliance using cine MRI in normal pressure hydrocephalus
    Mase, M
    Miyati, T
    Yamada, K
    Kasai, H
    Hara, M
    Shibamoto, Y
    Intracranial Pressure and Brain Monitoring XII, 2005, 95 : 303 - 306
  • [46] The Current State of Non-Invasive Measurement of Intracranial Pressure in Patients with Craniosynostosis: A Systematic Review
    Patel, Viren
    Lu, Quan
    Fodor, Ray
    Patel, Niyant
    FACE, 2024, 5 (03): : 451 - 462
  • [47] Research on non-invasive intracranial pressure measurement using near-infrared light
    Lin, L
    Li, G
    Xiang, SX
    Sun, JF
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT, 2002, 4916 : 450 - 456
  • [48] A PC Based System for Non-Invasive Measurement of Carotid Artery Compliance
    Joseph, Jayaraj
    Jayashankar, V.
    Kumar, V. Jagadeesh
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 656 - 661
  • [49] Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: A prospective observational study
    Robba, Chiara
    Cardim, Danilo
    Tajsic, Tamara
    Pietersen, Justine
    Bulman, Michael
    Donnelly, Joseph
    Lavinio, Andrea
    Gupta, Arun
    Menon, David K.
    Hutchinson, Peter J. A.
    Czosnyka, Marek
    PLOS MEDICINE, 2017, 14 (07)
  • [50] Graphical and statistical analyses of the oculocardiac reflex during a non-invasive intracranial pressure measurement
    Hamarat, Yasin
    Bartusis, Laimonas
    Deimantavicius, Mantas
    Siaudvytyte, Lina
    Januleviciene, Ingrida
    Ragauskas, Arminas
    Bershad, Eric M.
    Fandino, Javier
    Kienzler, Jenny
    Remonda, Elke
    Matijosaitis, Vaidas
    Rastenyte, Daiva
    Petrikonis, Kestutis
    Berskiene, Kristina
    Zakelis, Rolandas
    PLOS ONE, 2018, 13 (04):