Accuracy of non-invasive intracranial pressure measurement

被引:0
|
作者
Seddighi, Amir Saied [1 ]
Zadeh, Alireza Moqareh [2 ]
Seddighi, Afsoun [3 ]
Zali, Alireza [4 ]
机构
[1] Shahid Beheshti Univ Med Sci, Shohada Tajrish Hosp, Funct Neurosurg Res Ctr, Tehran 1445744454, Iran
[2] Shahed Univ, Tehran 1445744454, Iran
[3] Qazvin Univ Med Sci, Shahid Rajaee Hosp, Shohada Tajrish Hosp, Funct Neurosurg Res Ctr, Tehran 1445744454, Qazvin, Iran
[4] Shahid Beheshti Univ Med Sci, Shohada Tajrish Hosp, Neurofunct Res Ctr, Tehran 1445744454, Iran
来源
关键词
Intracranial pressure; Non-invasive; Monitoring; Brain; Tumor; CEREBRAL PERFUSION-PRESSURE; TRANSCRANIAL DOPPLER ULTRASONOGRAPHY; TRAUMATIC BRAIN-INJURY; BLOOD-PRESSURE; AUTOREGULATION; REACTIVITY; ICP;
D O I
10.2478/s11536-011-0129-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Non-invasive measurement of intracranial pressure (ICP) reduces the complications and cost for both patient and health care systems. Improvement of non-invasive methods has led to development of systems for reproducing continuous, real-time non-invasive ICP signals. So far, non-invasive methods have been tailored for the patients with head trauma. We have used Schmidt's auto-adaptive method to assess the accuracy of this method for patients after surgery for supratentorial brain tumors. Data from forty patients with the diagnosis of brain tumor operated from 2008 to 2010 were used to estimate the accuracy of Schmidt's method in our patients. We obtained the model parameters from 30 recordings. We determined the ICP wave form for the remaining patients by both invasive and non-invasive techniques. In the test group, by invasive method, the mean ICP +/- 2SD was 17.1 +/- 6.6 mmHg and using non-invasive method, the mean ICP +/- 2SD was 16.5 +/- 5.4 mmHg. The calculated error was 4.6 mmHg using root mean square errors. The average Pearson correlation between the estimated and real waveforms was 0.92. We believe that application of this method is acceptable for post-operative assessment of ICP in brain tumor patients.
引用
收藏
页码:169 / 175
页数:7
相关论文
共 50 条
  • [1] Non-invasive measurement of intracranial pressure
    Hartmann, A
    [J]. LANCET, 1998, 351 (9101): : 524 - 524
  • [2] Non-invasive technologies for intracranial pressure/volume measurement
    Ragauskas, A
    Petkus, V
    [J]. PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 259 - 262
  • [3] Accuracy, precision, sensitivity and specificity of non-invasive absolute intracranial pressure value measurement method
    Ragauskas, A.
    Bartusis, L.
    Zakelis, R.
    Daubaris, G.
    Krakauskaite, S.
    Matijosaitis, V.
    Petrikonis, K.
    Rastenyte, D.
    [J]. CEREBROVASCULAR DISEASES, 2014, 37 : 52 - 53
  • [4] Transcranial Bioimpedance Measurement as a Non-invasive Estimate of Intracranial Pressure
    Hawthorne, Christopher
    Shaw, Martin
    Piper, Ian
    Moss, Laura
    Kinsella, John
    [J]. INTRACRANIAL PRESSURE & NEUROMONITORING XVI, 2018, 126 : 89 - 92
  • [5] Non-invasive intracranial pressure assessment
    Padayachy, Llewellyn C.
    [J]. CHILDS NERVOUS SYSTEM, 2016, 32 (09) : 1587 - 1597
  • [6] Non-invasive assessment of intracranial pressure
    Robba, C.
    Bacigaluppi, S.
    Cardim, D.
    Donnelly, J.
    Bertuccio, A.
    Czosnyka, M.
    [J]. ACTA NEUROLOGICA SCANDINAVICA, 2016, 134 (01): : 4 - 21
  • [7] Non-invasive intracranial pressure assessment
    Llewellyn C. Padayachy
    [J]. Child's Nervous System, 2016, 32 : 1587 - 1597
  • [8] Non-Invasive Intracranial Pressure Monitoring
    Mueller, Sebastian Johannes
    Henkes, Elina
    Gounis, Matthew J.
    Felber, Stephan
    Ganslandt, Oliver
    Henkes, Hans
    [J]. JOURNAL OF CLINICAL MEDICINE, 2023, 12 (06)
  • [9] Non-invasive intracranial pressure measurement in progressive hydrocephalus and head injuries
    Michalk, D
    [J]. MONATSSCHRIFT KINDERHEILKUNDE, 1998, 146 (08) : 784 - 784
  • [10] NON-INVASIVE INTRACRANIAL-PRESSURE MEASUREMENT IN THE NEWBORN - AN ALTERNATE METHOD
    EASA, D
    TRAN, A
    BINGHAM, W
    [J]. AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1983, 137 (04): : 332 - 335