Reliability and Validity of Non-invasive Blood Pressure Measurement System Using Three-Axis Tactile Force Sensor

被引:12
|
作者
Yoo, Sun-Young [1 ]
Ahn, Ji-Eun [2 ]
Cserey, Gyoergy [3 ]
Lee, Hae-Young [4 ,5 ]
Seo, Jong-Mo [1 ,5 ]
机构
[1] Seoul Natl Univ, Inst Engn Res, Interuniv Semicond Res Ctr, Dept Elect & Comp Engn, Seoul 08826, South Korea
[2] Seoul Natl Univ, Interdisciplinary Program Bioengn, Seoul 03080, South Korea
[3] Pazmany Peter Catholic Univ, Fac Informat Technol & Bion, H-1083 Budapest, Hungary
[4] Seoul Natl Univ Hosp, Dept Internal Med, Seoul 03080, South Korea
[5] Seoul Natl Univ Hosp, Biomed Res Inst, Seoul 03080, South Korea
来源
SENSORS | 2019年 / 19卷 / 07期
关键词
non-invasive blood pressure measurement; radial arterial pressure; continuous blood pressure monitoring; three-axis tactile force sensor; ARTERY APPLANATION TONOMETRY; STATISTICAL-METHODS; VALIDATION; AGREEMENT;
D O I
10.3390/s19071744
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Blood pressure (BP) is a physiological parameter reflecting hemodynamic factors and is crucial in evaluating cardiovascular disease and its prognosis. In the present study, the reliability of a non-invasive and continuous BP measurement using a three-axis tactile force sensor was verified. All the data were collected every 2 min for the short-term experiment, and every 10 min for the long-term experiment. In addition, the effects on the BP measurement of external physical factors such as the tension to the radial artery on applying the device and wrist circumference were evaluated. A high correlation between the measured BP with the proposed system and with the cuff-based non-invasive blood pressure, and reproducibility, were demonstrated. All data satisfied the Association for the Advancement of Medical Instrumentation criteria. The external physical factors did not affect the measurement results. In addition to previous research indicating the high reliability of the arterial pulse waveforms, the present results have demonstrated the reliability of numerical BP values, and this implies that the three-axis force sensor can be used as a patient monitoring device.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Design of a Three-Axis Force Sensor Using Decoupled Compliant Parallel Mechanisms
    Li, Haiyang
    Yi, Longteng
    Leng, Chuyang
    Zhong, Yahan
    Hong, Jiaqi
    Song, Xueguan
    Hao, Guangbo
    IEEE SENSORS JOURNAL, 2024, 24 (15) : 23585 - 23598
  • [32] Advances in Non-Invasive Blood Pressure Measurement Techniques
    Panula, Tuukka
    Sirkia, Jukka-Pekka
    Wong, David
    Kaisti, Matti
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2023, 16 : 424 - 438
  • [33] Rhabdomyolysis complicating non-invasive blood pressure measurement
    Srinivasan, Chitra
    Kuppuswamy, Balaji
    INDIAN JOURNAL OF ANAESTHESIA, 2012, 56 (04) : 428 - U126
  • [34] New Perspectives on Non-invasive Blood Pressure Measurement
    Argha, Ahmadreza
    Celler, Branko G.
    Yong, Andy
    Rubenis, Imants
    Butlin, Mark
    Avolio, Alberto
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [35] Non-invasive blood pressure measurement displays - a reply
    Bailey, C. R.
    Nathanson, M. H.
    ANAESTHESIA, 2018, 73 (10) : 1300 - 1300
  • [36] Reliability and validity of non-invasive determined haemoglobin mass and blood volumes
    Fagoni, Nazzareno
    Andersen, Andreas Breenfeldt
    Oberholzer, Laura
    Haider, Thomas
    Lundby, Anne-Kristine Meinild
    Lundby, Carsten
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2018, 38 (02) : 240 - 245
  • [37] Non-Invasive Blood Pressure Monitoring with Positionable Three-chamber Pneumatic Sensor
    Antsiperov, V. E.
    Mansurov, G. K.
    Danilychev, M., V
    Churikov, D., V
    HEALTHINF: PROCEEDINGS OF THE 12TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES - VOL 5: HEALTHINF, 2019, : 462 - 465
  • [38] Sensor Calibration Models for a Non-Invasive Blood Glucose Measurement Sensor
    Stemmann, M.
    Stahl, F.
    Lallemand, J.
    Renard, E.
    Johansson, R.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 4979 - 4982
  • [39] Tactile expert system using a parallel-fingered hand fitted with three-axis tactile sensors
    Ohka, Masahiro
    Kobayashi, Mitsuo
    Shinokura, Tsuneki
    Sagisawa, Shinobu
    JSME International Journal, Series C: Dynamics, Control, Robotics, Design and Manufacturing, 1994, 37 (01): : 138 - 146
  • [40] Non-invasive measurement of blood pressure and prevalence of blood pressure anomalies in dogs
    Gaur, T
    Varshney, JP
    INDIAN JOURNAL OF ANIMAL SCIENCES, 2002, 72 (01): : 68 - 69