Reliability and Validity of Non-invasive Blood Pressure Measurement System Using Three-Axis Tactile Force Sensor

被引:12
|
作者
Yoo, Sun-Young [1 ]
Ahn, Ji-Eun [2 ]
Cserey, Gyoergy [3 ]
Lee, Hae-Young [4 ,5 ]
Seo, Jong-Mo [1 ,5 ]
机构
[1] Seoul Natl Univ, Inst Engn Res, Interuniv Semicond Res Ctr, Dept Elect & Comp Engn, Seoul 08826, South Korea
[2] Seoul Natl Univ, Interdisciplinary Program Bioengn, Seoul 03080, South Korea
[3] Pazmany Peter Catholic Univ, Fac Informat Technol & Bion, H-1083 Budapest, Hungary
[4] Seoul Natl Univ Hosp, Dept Internal Med, Seoul 03080, South Korea
[5] Seoul Natl Univ Hosp, Biomed Res Inst, Seoul 03080, South Korea
来源
SENSORS | 2019年 / 19卷 / 07期
关键词
non-invasive blood pressure measurement; radial arterial pressure; continuous blood pressure monitoring; three-axis tactile force sensor; ARTERY APPLANATION TONOMETRY; STATISTICAL-METHODS; VALIDATION; AGREEMENT;
D O I
10.3390/s19071744
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Blood pressure (BP) is a physiological parameter reflecting hemodynamic factors and is crucial in evaluating cardiovascular disease and its prognosis. In the present study, the reliability of a non-invasive and continuous BP measurement using a three-axis tactile force sensor was verified. All the data were collected every 2 min for the short-term experiment, and every 10 min for the long-term experiment. In addition, the effects on the BP measurement of external physical factors such as the tension to the radial artery on applying the device and wrist circumference were evaluated. A high correlation between the measured BP with the proposed system and with the cuff-based non-invasive blood pressure, and reproducibility, were demonstrated. All data satisfied the Association for the Advancement of Medical Instrumentation criteria. The external physical factors did not affect the measurement results. In addition to previous research indicating the high reliability of the arterial pulse waveforms, the present results have demonstrated the reliability of numerical BP values, and this implies that the three-axis force sensor can be used as a patient monitoring device.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] A comparison of invasive arterial blood pressure measurement with oscillometric non-invasive blood pressure measurement in patients with sepsis
    Jiang, Ziqing
    Li, Shaoying
    Wang, Lin
    Yu, Feng
    Zeng, Yanping
    Li, Hongbo
    Li, Jun
    Zhang, Zhanfeng
    Zuo, Junling
    JOURNAL OF ANESTHESIA, 2024, 38 (02) : 222 - 231
  • [42] A comparison of invasive arterial blood pressure measurement with oscillometric non-invasive blood pressure measurement in patients with sepsis
    Ziqing Jiang
    Shaoying Li
    Lin Wang
    Feng Yu
    Yanping Zeng
    Hongbo Li
    Jun Li
    Zhanfeng Zhang
    Junling Zuo
    Journal of Anesthesia, 2024, 38 : 222 - 231
  • [43] Object exploration and manipulation using a robotic finger equipped with an optical three-axis tactile sensor
    Ohka, Masahiro
    Takata, Jumpei
    Kobayashi, Hiroaki
    Suzuki, Hirofumi
    Morisawa, Nobuyuki
    Bin Yussof, Hanafiah
    ROBOTICA, 2009, 27 : 763 - 770
  • [44] Non-invasive assessment of arterial stiffness using oscillometric blood pressure measurement
    Hidehiko Komine
    Yoshiyuki Asai
    Takashi Yokoi
    Mutsuko Yoshizawa
    BioMedical Engineering OnLine, 11
  • [45] Non-invasive assessment of arterial stiffness using oscillometric blood pressure measurement
    Komine, Hidehiko
    Asai, Yoshiyuki
    Yokoi, Takashi
    Yoshizawa, Mutsuko
    BIOMEDICAL ENGINEERING ONLINE, 2012, 11
  • [46] A non-invasive capacitive sensor strip for aerodynamic pressure measurement
    Zagnoni, A
    Golfarelli, A
    Callegari, S
    Talamelli, A
    Bonora, V
    Sangiorgi, E
    Tartagni, M
    SENSORS AND ACTUATORS A-PHYSICAL, 2005, 123-24 : 240 - 248
  • [47] Portable Non-invasive Blood Pressure Measurement using Pulse Transmit Time
    Noche, Kaiser Josephus B.
    Flores Villaverde, Jocelyn
    Lazaro, Jose, Jr.
    2017 IEEE 9TH INTERNATIONAL CONFERENCE ON HUMANOID, NANOTECHNOLOGY, INFORMATION TECHNOLOGY, COMMUNICATION AND CONTROL, ENVIRONMENT AND MANAGEMENT (IEEE HNICEM), 2017,
  • [48] A novel non-invasive wearable sensor for intraocular pressure measurement
    Campigotto, Angelica
    Lai, Yongjun
    Medical Devices and Sensors, 2020, 3 (03):
  • [49] Sensor System Concept for Non-Invasive Blood Diagnosis
    Timm, U.
    Lewis, E.
    McGrath, D.
    Kraitl, J.
    Ewald, H.
    PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01): : 493 - +
  • [50] OPTICAL SENSOR SYSTEM FOR NON-INVASIVE BLOOD DIAGNOSIS
    Timm, U.
    Lewis, E.
    McGrath, D.
    Kraitl, J.
    Ewald, H.
    SAS 2009 - IEEE SENSORS APPLICATIONS SYMPOSIUM, PROCEEDINGS, 2009, : 210 - +