Reliability and Validity of Non-invasive Blood Pressure Measurement System Using Three-Axis Tactile Force Sensor

被引:12
|
作者
Yoo, Sun-Young [1 ]
Ahn, Ji-Eun [2 ]
Cserey, Gyoergy [3 ]
Lee, Hae-Young [4 ,5 ]
Seo, Jong-Mo [1 ,5 ]
机构
[1] Seoul Natl Univ, Inst Engn Res, Interuniv Semicond Res Ctr, Dept Elect & Comp Engn, Seoul 08826, South Korea
[2] Seoul Natl Univ, Interdisciplinary Program Bioengn, Seoul 03080, South Korea
[3] Pazmany Peter Catholic Univ, Fac Informat Technol & Bion, H-1083 Budapest, Hungary
[4] Seoul Natl Univ Hosp, Dept Internal Med, Seoul 03080, South Korea
[5] Seoul Natl Univ Hosp, Biomed Res Inst, Seoul 03080, South Korea
来源
SENSORS | 2019年 / 19卷 / 07期
关键词
non-invasive blood pressure measurement; radial arterial pressure; continuous blood pressure monitoring; three-axis tactile force sensor; ARTERY APPLANATION TONOMETRY; STATISTICAL-METHODS; VALIDATION; AGREEMENT;
D O I
10.3390/s19071744
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Blood pressure (BP) is a physiological parameter reflecting hemodynamic factors and is crucial in evaluating cardiovascular disease and its prognosis. In the present study, the reliability of a non-invasive and continuous BP measurement using a three-axis tactile force sensor was verified. All the data were collected every 2 min for the short-term experiment, and every 10 min for the long-term experiment. In addition, the effects on the BP measurement of external physical factors such as the tension to the radial artery on applying the device and wrist circumference were evaluated. A high correlation between the measured BP with the proposed system and with the cuff-based non-invasive blood pressure, and reproducibility, were demonstrated. All data satisfied the Association for the Advancement of Medical Instrumentation criteria. The external physical factors did not affect the measurement results. In addition to previous research indicating the high reliability of the arterial pulse waveforms, the present results have demonstrated the reliability of numerical BP values, and this implies that the three-axis force sensor can be used as a patient monitoring device.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] P89 Non-invasive Blood Pressure Measurement System Using Three-axis Tactile Force Sensor
    Hae-Young Lee
    Artery Research, 2019, 25 (Suppl 1) : S132 - S132
  • [2] Flexible Piezoelectric Tactile Sensor Array for Dynamic Three-Axis Force Measurement
    Yu, Ping
    Liu, Weiting
    Gu, Chunxin
    Cheng, Xiaoying
    Fu, Xin
    SENSORS, 2016, 16 (06):
  • [3] Three-Axis Contact Force Measurement of a Flexible Tactile Sensor Array for Hand Grasping Applications
    Wang, Yancheng
    Xi, Kailun
    Mei, Deqing
    Xin, Zhihao
    Chen, Zichen
    WEARABLE SENSORS AND ROBOTS, 2017, 399 : 67 - 79
  • [4] MICROPILLAR TYPE THREE-AXIS FORCE SENSOR FOR MEASUREMENT OF CELLULAR FORCE
    Omiya, T.
    Tsukagoshi, T.
    Hirayama, K.
    Thanh-Vinh, N.
    Noda, K.
    Matsumoto, K.
    Shimoyama, I.
    2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2015, : 188 - 191
  • [5] Velocity measurement using MEMS ultrasonic sensor for non-invasive blood pressure measurement
    Takei Y.
    Matsui R.
    Minh-Dung N.
    Takahata T.
    Matsumoto K.
    Shimoyama I.
    IEEJ Transactions on Sensors and Micromachines, 2018, 138 (02) : 54 - 58
  • [6] Real-time measurement of the three-axis contact force distribution using a flexible capacitive polymer tactile sensor
    Lee, Hyung-Kew
    Chung, Jaehoon
    Chang, Sun-Il
    Yoon, Euisik
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2011, 21 (03)
  • [7] Flexible Capacitive Tactile Sensor Array With Truncated Pyramids as Dielectric Layer for Three-Axis Force Measurement
    Liang, Guanhao
    Wang, Yancheng
    Mei, Deqing
    Xi, Kailun
    Chen, Zichen
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2015, 24 (05) : 1510 - 1519
  • [8] A Flexible Tactile Sensor Array based on Pressure Conductive Rubber for Three-Axis Force and Slip Detection
    Xi, Kailun
    Wang, Yancheng
    Mei, Deqing
    Liang, Guanhao
    Chen, Zichen
    2015 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2015, : 476 - 481
  • [9] Sensor fusion for the accurate non-invasive measurement of blood pressure
    Nagy P.
    Jobbágy Á.
    Measurement: Sensors, 2022, 24
  • [10] Evaluation of the perceived elasticity of sheepskin using a three-axis force sensor system
    Kwon, Euichul
    Kamijo, Masayoshi
    Takatera, Masayuki
    TEXTILE RESEARCH JOURNAL, 2012, 82 (08) : 845 - 852