Sensor fusion for the accurate non-invasive measurement of blood pressure

被引:0
|
作者
Nagy P. [1 ]
Jobbágy Á. [1 ]
机构
[1] Department of Measurement and Information Systems, Faculty of Electrical Engineering and Informatics, Budapest University of Technology and Economics, Magyar tudósok körútja 2, Budapest
来源
Measurement: Sensors | 2022年 / 24卷
关键词
Blood pressure measurement; Photoplethysmography; Sensor fusion; Stress;
D O I
10.1016/j.measen.2022.100481
中图分类号
学科分类号
摘要
The paper demonstrates that ECG and photoplethysmographic (PPG) signals recorded in parallel with cuff pressure help improve the accuracy of non-invasive blood pressure (BP) measurement. The proposed method eliminates erroneous results of automatic BP monitors caused by increased arterial stiffness and/or arrhythmia. In addition, it provides a feasible estimate on stress level of the test subject. 138 recordings of 54 subjects were taken both at rest and after a short physical exercise on patients with cardiovascular disease, as well as healthy control subjects. Further five hundred previously taken measurements were re-evaluated for algorithm development. The proposed method is able to determine systolic blood pressure (SBP) both during inflation and deflation. The deviation from the gold standard was −0.7 ± 1.5 mmHg for SBPinfl and −0.3 ± 1.8 mmHg for SBPdefl. The extra information of ECG and PPG reveals that even after short physical exercise 10-min rest is required before BP measurement. The extra information makes SBP estimation of patients with left ventricular assist device (LVAD) possible, which oscillometric monitors are unable to do. The method reported in this paper is expected to be introduced for BP measurement both in hospital and at home for patients with arrhythmia and living with LVAD. © 2022 The Authors
引用
收藏
相关论文
共 50 条
  • [1] Velocity measurement using MEMS ultrasonic sensor for non-invasive blood pressure measurement
    Takei Y.
    Matsui R.
    Minh-Dung N.
    Takahata T.
    Matsumoto K.
    Shimoyama I.
    IEEJ Transactions on Sensors and Micromachines, 2018, 138 (02) : 54 - 58
  • [2] Measurement of Blood Pressure via a Skin-Mounted, Non-Invasive Pressure Sensor
    Li, Shupeng
    Park, Yoonseok
    Luan, Haiwen
    Wang, Heling
    Kwon, Kyeongha
    Rogers, John A.
    Huang, Yonggang
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 2021, 88 (10):
  • [3] Non-invasive blood pressure measurement displays
    Scott, D. H. T.
    ANAESTHESIA, 2018, 73 (10) : 1299 - 1299
  • [4] NON-INVASIVE BLOOD-PRESSURE MEASUREMENT
    PAULUS, DA
    MEDICAL INSTRUMENTATION, 1981, 15 (02): : 91 - 94
  • [5] THE MEAN MACHINE; ACCURATE NON-INVASIVE BLOOD PRESSURE MEASUREMENT IN THE CRITICALLY ILL PATIENT
    Muecke, Sandy
    Bersten, Andrew
    Plummer, John
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2009, 23 (05) : 283 - 297
  • [6] The Mean Machine; Accurate Non-invasive Blood Pressure Measurement in the Critically Ill Patient
    Sandy Muecke
    Andrew Bersten
    John Plummer
    Journal of Clinical Monitoring and Computing, 2009, 23 : 283 - 297
  • [7] THREE INFLUENCING FACTORS FOR THE ACCURATE MEASUREMENT OF NON-INVASIVE CENTRAL BLOOD PRESSURE AS COMPARED TO INVASIVE MEASUREMENT: THE MATCHY STUDY
    Chi, C.
    Zhou, Y.
    Lu, Y.
    Tang, Y.
    Li, Y.
    Zhang, Y.
    Xu, Y.
    JOURNAL OF HYPERTENSION, 2019, 37 : E43 - E44
  • [8] TOWARDS ACCURATE NON-INVASIVE MEASUREMENT OF ARTERIAL-PRESSURE
    FINNIE, KJC
    ARMSTRONG, PW
    CLINICAL RESEARCH, 1980, 28 (02): : A168 - A168
  • [9] Non-invasive blood pressure measurement in dogs and cats
    Mandigers, P
    TIJDSCHRIFT VOOR DIERGENEESKUNDE, 2005, 130 (07) : 198 - 201
  • [10] Advances in Non-Invasive Blood Pressure Measurement Techniques
    Panula, Tuukka
    Sirkia, Jukka-Pekka
    Wong, David
    Kaisti, Matti
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2023, 16 : 424 - 438