Sensor fusion for the accurate non-invasive measurement of blood pressure

被引:0
|
作者
Nagy P. [1 ]
Jobbágy Á. [1 ]
机构
[1] Department of Measurement and Information Systems, Faculty of Electrical Engineering and Informatics, Budapest University of Technology and Economics, Magyar tudósok körútja 2, Budapest
来源
Measurement: Sensors | 2022年 / 24卷
关键词
Blood pressure measurement; Photoplethysmography; Sensor fusion; Stress;
D O I
10.1016/j.measen.2022.100481
中图分类号
学科分类号
摘要
The paper demonstrates that ECG and photoplethysmographic (PPG) signals recorded in parallel with cuff pressure help improve the accuracy of non-invasive blood pressure (BP) measurement. The proposed method eliminates erroneous results of automatic BP monitors caused by increased arterial stiffness and/or arrhythmia. In addition, it provides a feasible estimate on stress level of the test subject. 138 recordings of 54 subjects were taken both at rest and after a short physical exercise on patients with cardiovascular disease, as well as healthy control subjects. Further five hundred previously taken measurements were re-evaluated for algorithm development. The proposed method is able to determine systolic blood pressure (SBP) both during inflation and deflation. The deviation from the gold standard was −0.7 ± 1.5 mmHg for SBPinfl and −0.3 ± 1.8 mmHg for SBPdefl. The extra information of ECG and PPG reveals that even after short physical exercise 10-min rest is required before BP measurement. The extra information makes SBP estimation of patients with left ventricular assist device (LVAD) possible, which oscillometric monitors are unable to do. The method reported in this paper is expected to be introduced for BP measurement both in hospital and at home for patients with arrhythmia and living with LVAD. © 2022 The Authors
引用
收藏
相关论文
共 50 条
  • [41] A microwave frequency sensor for non-invasive blood-glucose measurement
    Jean, Buford Randall
    Green, Eric C.
    McClung, Melanie J.
    2008 IEEE SENSORS APPLICATIONS SYMPOSIUM, 2008, : 4 - 7
  • [42] A New Non-Invasive Cuff-Less Blood Pressure Sensor
    Tu, Tse-Yi
    Chao, Paul C. -P.
    Lee, Yung-Pin
    2013 IEEE SENSORS, 2013, : 857 - 860
  • [43] NON-INVASIVE MEASUREMENT OF VENTRICULAR PRESSURE
    SOUTHON, FCG
    AMERICAN JOURNAL OF CARDIOLOGY, 1981, 48 (03): : 592 - 592
  • [44] Non-invasive measurement of intracranial pressure
    Hartmann, A
    LANCET, 1998, 351 (9101): : 524 - 524
  • [45] Non-invasive Measurement of Portal Pressure
    Elmahdy A.M.
    Berzigotti A.
    Current Hepatology Reports, 2019, 18 (1) : 20 - 27
  • [46] Non-invasive blood pressure measurement based on the electronic palpation method
    Nissilä, S
    Sorvisto, M
    Sorvoja, H
    Vieri-Gashi, E
    Myllylä, R
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 1723 - 1726
  • [47] Clinical Implications of Non-Invasive Measurement of Central Aortic Blood Pressure
    Stepien, Mariusz
    Banach, Maciej
    Jankowski, Piotr
    Rysz, Jacek
    CURRENT VASCULAR PHARMACOLOGY, 2010, 8 (06) : 747 - 752
  • [48] Accuracy of non-invasive blood pressure measurement in patients with atrial fibrillation
    Hai Su
    Zihong Guo
    Journal of Human Hypertension, 2022, 36 : 229 - 234
  • [49] Impedance Cardiography for Cuffless and Non-invasive Measurement of Systolic Blood Pressure
    Wong, M. Y. M.
    Pickwell-MacPherson, E.
    Zhang, Y. T.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 800 - 802
  • [50] Accuracy of non-invasive blood pressure measurement in patients with atrial fibrillation
    Su, Hai
    Guo, Zihong
    JOURNAL OF HUMAN HYPERTENSION, 2022, 36 (03) : 229 - 234