Sensor fusion for the accurate non-invasive measurement of blood pressure

被引:0
|
作者
Nagy P. [1 ]
Jobbágy Á. [1 ]
机构
[1] Department of Measurement and Information Systems, Faculty of Electrical Engineering and Informatics, Budapest University of Technology and Economics, Magyar tudósok körútja 2, Budapest
来源
Measurement: Sensors | 2022年 / 24卷
关键词
Blood pressure measurement; Photoplethysmography; Sensor fusion; Stress;
D O I
10.1016/j.measen.2022.100481
中图分类号
学科分类号
摘要
The paper demonstrates that ECG and photoplethysmographic (PPG) signals recorded in parallel with cuff pressure help improve the accuracy of non-invasive blood pressure (BP) measurement. The proposed method eliminates erroneous results of automatic BP monitors caused by increased arterial stiffness and/or arrhythmia. In addition, it provides a feasible estimate on stress level of the test subject. 138 recordings of 54 subjects were taken both at rest and after a short physical exercise on patients with cardiovascular disease, as well as healthy control subjects. Further five hundred previously taken measurements were re-evaluated for algorithm development. The proposed method is able to determine systolic blood pressure (SBP) both during inflation and deflation. The deviation from the gold standard was −0.7 ± 1.5 mmHg for SBPinfl and −0.3 ± 1.8 mmHg for SBPdefl. The extra information of ECG and PPG reveals that even after short physical exercise 10-min rest is required before BP measurement. The extra information makes SBP estimation of patients with left ventricular assist device (LVAD) possible, which oscillometric monitors are unable to do. The method reported in this paper is expected to be introduced for BP measurement both in hospital and at home for patients with arrhythmia and living with LVAD. © 2022 The Authors
引用
收藏
相关论文
共 50 条
  • [31] Feasibility of continuous non-invasive blood pressure measurement in infants
    Schraa, O
    Andriessen, P
    Smit, B
    van den Bosch-Ruis, W
    van Koppen, M
    Settels, JJ
    JOURNAL OF HYPERTENSION, 2004, 22 : S280 - S280
  • [32] Concept for a Permanent, Non-Invasive Blood Pressure Measurement in the Ear
    Zeilfelder, Jennifer
    Diehl, Matthias
    Pylatiuk, Christian
    Stork, Wilhelm
    2019 IEEE EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL & HEALTH INFORMATICS (BHI), 2019,
  • [33] Assessing the strengths and limitations of non-invasive blood pressure measurement
    Hanover, Jeffrey
    JOURNAL OF CLINICAL HYPERTENSION, 2023, 25 (10): : 965 - 966
  • [34] SUITABILITY OF THE FOREARM FOR AUTOMATED NON-INVASIVE BLOOD PRESSURE MEASUREMENT
    Rajan, N.
    Rao, S. L.
    ANESTHESIA AND ANALGESIA, 2014, 118 : S22 - S22
  • [35] Non-invasive blood pressure measurement in animals: Part 1-Techniques for measurement and validation of non-invasive devices
    Skelding, Alicia
    Valverde, Alexander
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2020, 61 (04): : 368 - 374
  • [36] A new indicator for non-invasive arterial blood pressure measurement
    Regueiro-Gomez, A
    Pallas-Areny, R
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 117 - 118
  • [37] Non-invasive carbon monoxide measurement is not accurate
    O'Malley, Gerald F.
    ANNALS OF EMERGENCY MEDICINE, 2006, 48 (04) : 477 - 478
  • [38] DEVELOPMENT OF A SENSOR FOR NON-INVASIVE INTRACRANIAL-PRESSURE MEASUREMENT IN THE NEWBORN
    BURTON, PJ
    ROCHEFORT, M
    ROLFE, P
    GODDARD, PJ
    JOURNAL OF BIOMEDICAL ENGINEERING, 1988, 10 (02): : 171 - 174
  • [39] The peripheral venous pressure changes during non-invasive blood pressure measurement
    Sim, JY
    Choi, Y
    Yoon, MJ
    Lee, DM
    Leem, JW
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (07): : 711 - 712
  • [40] The peripheral venous pressure changes during non-invasive blood pressure measurement
    J. Y. Sim
    Y. Choi
    M. J. Yoon
    D. M. Lee
    J. W. Leem
    Canadian Journal of Anesthesia, 1999, 46 : 711 - 712