Traceable calibration of a broadband seismometer down to 5 mHz

被引:4
|
作者
Shimoda, Tomofumi [1 ]
Kokuyama, Wataru [1 ]
Nozato, Hideaki [1 ]
机构
[1] Natl Metrol Inst Japan, Natl Inst Adv Ind Sci & Technol, 1-1-1 Umezono, Tsukuba, Ibaraki 3058563, Japan
关键词
seismometer; calibration; traceability; low-frequency vibration; tilt coupling;
D O I
10.1088/1361-6501/ac9077
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Broadband seismometers have been widely employed in geophysical observation and disaster prevention. To ensure the reliability of the measurement, traceable calibration of their sensitivities following ISO 16063-11 down to 8 mHz is required. However, the calibration accuracy generally degrades below 0.1 Hz due to tilt-coupling error. In this paper, two tilt-coupling correction methods are investigated: one is a dynamic tilt measurement method using an autocollimator, and the other is a comparison method using a reference accelerometer. These methods were introduced to the primary calibration system to calibrate a seismometer between 5 mHz and 200 Hz. As a result, the tilt-coupling error was corrected with an estimated uncertainty of less than 2% at 5 mHz, and the bandpass response of the seismometer sensitivity was confirmed with the traceable method.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Traceable calibration of impedance heads and artificial mastoids
    Scott, D. A.
    Dickinson, L. P.
    Bell, T. J.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (12)
  • [32] Traceable measurement methods for dynamic pressure calibration
    Yang Jun
    Zhang Li
    Xue Bin
    Huang Riheng
    Li Bo
    PROCEEDINGS OF 2017 13TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), VOL 1, 2017, : 545 - 551
  • [33] A simple traceable current transformer calibration method
    Corney, AC
    2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 660 - 661
  • [34] Correlation processing techniques in frequency-domain calibration for very broadband seismometer - Raising sinewave calibration precision under strong noise by using vertical correlation method
    Zhou, Yunyao
    Cai, Yaxian
    Wuhan Daxue Xuebao (Xinxi Kexue Ban)/Geomatics and Information Science of Wuhan University, 2005, 30 (07): : 632 - 635
  • [35] Advances in traceable calibration of cylinder pressure transducers
    Salminen, J.
    Saxholm, S.
    Hamalainen, J.
    Hogstrom, R.
    METROLOGIA, 2020, 57 (04)
  • [36] Remote Status Monitoring of Broadband Seismometer Based on the Mobile Internet
    Lv, Shixue
    Zhang, Huaizhu
    Lin, Jun
    Long, Yun
    Yuan, Shuai
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ENGINEERING GEOPHYSICS (ICEEG) & SUMMIT FORUM OF CHINESE ACADEMY OF ENGINEERING ON ENGINEERING SCIENCE AND TECHNOLOGY, 2016, 71 : 450 - 451
  • [37] Transfer function of FBS-3A feedback broadband seismometer
    Liu, Q.
    Zhuang, C.
    Liu, H.
    Acta Seismologica Sinica English Edition, 2001, 14 (01): : 82 - 90
  • [38] TRACEABLE CALIBRATION OF A CARDIAC DEFIBRILLATOR ENERGY METER
    STOCKTON, JR
    SMITH, RC
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1981, 19 (01) : 40 - 48
  • [39] Traceable Calibration of Atmospheric Oxidized Mercury Measurements
    Elgiar, Tyler R.
    Lyman, Seth N.
    Andron, Teodor D.
    Gratz, Lynne
    Hallar, A. Gannet
    Horvat, Milena
    Vijayakumaran Nair, Sreekanth
    O'Neil, Trevor
    Volkamer, Rainer
    Zivkovic, Igor
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2024, 58 (24) : 10706 - 10716
  • [40] The Traceable Calibration of Thrust Stand by Electrostatic Force
    Wang, Bin
    Yang, Yong
    Hu, Zhan
    Zheng, Yelong
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (181):