Traceable calibration of a broadband seismometer down to 5 mHz

被引:4
|
作者
Shimoda, Tomofumi [1 ]
Kokuyama, Wataru [1 ]
Nozato, Hideaki [1 ]
机构
[1] Natl Metrol Inst Japan, Natl Inst Adv Ind Sci & Technol, 1-1-1 Umezono, Tsukuba, Ibaraki 3058563, Japan
关键词
seismometer; calibration; traceability; low-frequency vibration; tilt coupling;
D O I
10.1088/1361-6501/ac9077
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Broadband seismometers have been widely employed in geophysical observation and disaster prevention. To ensure the reliability of the measurement, traceable calibration of their sensitivities following ISO 16063-11 down to 8 mHz is required. However, the calibration accuracy generally degrades below 0.1 Hz due to tilt-coupling error. In this paper, two tilt-coupling correction methods are investigated: one is a dynamic tilt measurement method using an autocollimator, and the other is a comparison method using a reference accelerometer. These methods were introduced to the primary calibration system to calibrate a seismometer between 5 mHz and 200 Hz. As a result, the tilt-coupling error was corrected with an estimated uncertainty of less than 2% at 5 mHz, and the bandpass response of the seismometer sensitivity was confirmed with the traceable method.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Laser-interferometric broadband seismometer for ocean borehole observations
    Araya, A.
    Sekiya, K.
    Shindo, Y.
    2007 Symposium on Underwater Technology and Workshop on Scientific Use of Submarine Cables and Related Technologies, Vols 1 and 2, 2007, : 245 - 248
  • [42] Laser-Interferometric Broadband Seismometer for Epicenter Location Estimation
    Lee, Kyunghyun
    Kwon, Hyungkwan
    You, Kwanho
    SENSORS, 2017, 17 (10)
  • [43] Transfer function of FBS-3A feedback broadband seismometer
    刘庆伟
    庄灿涛
    刘慧宁
    Acta Seismologica Sinica, 2001, (01) : 82 - 90
  • [44] Estimate the measurement uncertainty of broadband antenna (30MHz to 1GHz) calibration system
    Tsai, Jung-Chun
    Lin, Liang-Yang
    Tsai, Yung-Cheng
    Chen, Cheng-Chang
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 945 - 948
  • [46] CALIBRATION OF THE STS-1 SEISMOMETER - PRELIMINARY-RESULTS
    FELS, JF
    PHYSICS OF THE EARTH AND PLANETARY INTERIORS, 1994, 84 (1-4) : 299 - 304
  • [47] Uncertainty Budget for a Traceable Operational Radiometric Calibration of Field Spectroradiometers, Calibration of the Heliosphere
    Werfeli, Mike
    Hueni, Andreas
    Ganeva, Dessislava
    Ghielmetti, Giulia
    Mihai, Laura
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2024, 17 : 400 - 410
  • [48] Accurate and traceable calibration of one-dimensional gratings
    Dai, GL
    Koenders, L
    Pohlenz, F
    Dziomba, T
    Danzebrink, HU
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (06) : 1241 - 1249
  • [49] Calibration of a flatbed scanner for traceable paper area measurement
    Kangasraasio, J.
    Hemming, B.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (10)
  • [50] Traceable calibration of a critical dimension atomic force microscope
    Dixson, Ronald
    Orji, Ndubuisi G.
    McGray, Craig D.
    Bonevich, John
    Geist, Jon
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2012, 11 (01):