A frequency domain compensation scheme for multi-slice helical CT reconstruction with tilted gantry

被引:1
|
作者
Hsieh, J [1 ]
Hu, H [1 ]
机构
[1] GE Co, Med Syst, Milwaukee, WI 53201 USA
关键词
multi-slice computed tomography; tilted helical scan; tomographic reconstruction; image artifact;
D O I
10.1117/12.430998
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Multi-slice CT (MCT) is one of the most recent technical advancements in computed tomography. MCT offers high volume coverage, faster scan speed, and reduced x-ray tube loading. When combined with the helical scan mode, MCT provides even higher volume coverage as a result of the elimination of the inter-scan delays. Similar to the single slice CT, the projection data collected in MCT is inherently inconsistent.. To combat projection inconsistency, many image reconstruction algorithms were investigated and developed. Recent studies, have shown, however, that the image quality of MCT can be significantly degraded when the data is collected in a tilted helical mode. The degradation can be so severe that it is unacceptable for routine clinical usage. In this paper, we present a detailed investigation to, show that the root cause of the image quality degradation is the deviation of the reconstruction iso-center from the gantry iso-center. An analytical model is derived to establish a quantitative relationship between the iso-center shift and other system parameters. The model serves as the mathematical basis for the derivation of a frequency-domain correction algorithm. Detailed performance evaluation is provided in terms of spatial resolution, noise, computational efficiency, and image artifacts.
引用
收藏
页码:105 / 112
页数:4
相关论文
共 50 条
  • [11] Multi-slice CT image reconstruction
    Hsieh, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2225 - 2225
  • [12] Windmill artifact in multi-slice helical CT
    Silver, M
    Taguchi, K
    Hein, I
    Chiang, BS
    Kazama, M
    Mori, I
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1918 - 1927
  • [13] Improvement of Efficiency and Flexibility in Multi-slice Helical CT
    孙文武
    陈思平
    庄天戈
    JournalofShanghaiJiaotongUniversity(Science), 2008, (04) : 408 - 412
  • [14] The effect of pitch in multi-slice spiral/helical CT
    Wang, G
    Vannier, MW
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 116 - 127
  • [15] How to increase helical pitch in multi-slice CT
    Silver, MD
    Taguchi, K
    Hein, IA
    RADIOLOGY, 2001, 221 : 217 - 218
  • [16] Efficient Extended Field of View (eFOV) reconstruction techniques for multi-slice helical CT
    Bruder, H.
    Suess, C.
    Stierstorfer, K.
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [17] Temporal resolution of electrocardiogram (ECG)-gated retrospective reconstruction for multi-slice helical CT
    Ota, T
    Adachi, A
    Taguchi, K
    RADIOLOGY, 2000, 217 : 161 - 162
  • [18] Improvement of efficiency and flexibility in multi-slice helical CT
    Sun W.-W.
    Chen S.-P.
    Zhuang T.-G.
    J. Shanghai Jiaotong Univ. Sci., 2008, 4 (408-412): : 408 - 412
  • [19] Low Dose Multi-Slice Helical CT Reconstruction Using Tight Frame Regularization
    Tian, Z.
    Jia, X.
    Dong, B.
    Lou, Y.
    Jiang, S.
    MEDICAL PHYSICS, 2011, 38 (06) : 3798 - +
  • [20] Segmented multiple plane reconstruction: a novel approximate reconstruction scheme for multi-slice spiral CT
    Stierstorfer, K
    Flohr, T
    Bruder, H
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (15): : 2571 - 2581