The effect of pitch in multi-slice spiral/helical CT

被引:0
|
作者
Wang, G [1 ]
Vannier, MW [1 ]
机构
[1] Univ Iowa, Dept Radiol, Iowa City, IA 52242 USA
来源
关键词
computed tomography (CT); spiral/helical technique; multi-rows of detectors; multi-slices; data interpolation; image quality; sensitivity analysis; imaging protocol optimization;
D O I
10.1117/12.363713
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PURPOSE: To understand the effect of pitch on raw data interpolation in multi-slice spiral/helical CT, and provide guidelines for scanner design and protocol optimization. METHODS: Multi-slice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the detector collimation, and the table increment per X-ray source rotation. The pitch in multi-slice spiral CT is defined as the ratio of the table increment over the detector collimation. In parallel to the current framework for studying longitudinal image resolution, the central fan-beam rays of direct and opposite directions are considered, assuming a narrow cone-beam angle. Generally speaking, sampling in the Radon domain by the direct and opposite central rays is non-uniform along the longitudinal axis. Using a recently developed methodology for quantifying the sensitivity of signal reconstruction from non-uniformly sampled finite points, the effect of pitch on raw data interpolation is analyzed in multi-slice spiral CT. RESULTS: Unlike single-slice spiral CT, in which image quality decreases monotonically as the pitch increases, the sensitivity of raw data interpolation in multi-slice spiral CT increases in an alternating way as the pitch increases, suggesting that image quality does not decrease monotonically in this case. The most favorable pitch can be found from the sensitivity-pitch plot for any given set of multi-slice spiral CT parameters. An example for four-slice spiral CT is provided. CONCLUSION: The study on the pitch effect using the sensitivity analysis approach reveals the fundamental characteristics of raw data interpolation in multi-slice spiral CT, and gives insights into interaction between pitch and image quality. These results may be valuable for design of multi-slice spiral CT scanners and imaging protocol optimization in clinical applications.
引用
收藏
页码:116 / 127
页数:12
相关论文
共 50 条
  • [1] How to increase helical pitch in multi-slice CT
    Silver, MD
    Taguchi, K
    Hein, IA
    [J]. RADIOLOGY, 2001, 221 : 217 - 218
  • [2] Field-of-view dependent helical pitch in multi-slice CT
    Silver, MD
    Taguchi, K
    Han, KS
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 839 - 850
  • [3] Dose in multi-slice spiral CT
    Spreiter, Q
    Doubrava, C
    von der Haar, T
    Flohr, T
    Schaller, S
    [J]. PHYSICA MEDICA, 2000, 16 (03) : 151 - 154
  • [4] Multi-slice helical CT: biggest pitch does not mean dosimetric bargain
    Cordoliani, YS
    [J]. JOURNAL DE RADIOLOGIE, 2000, 81 (06): : 587 - 588
  • [5] Technical advances in multi-slice spiral CT
    Fuchs, T
    Kachelriess, M
    Kalender, WA
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2000, 36 (02) : 69 - 73
  • [6] Windmill artifact in multi-slice helical CT
    Silver, M
    Taguchi, K
    Hein, I
    Chiang, BS
    Kazama, M
    Mori, I
    [J]. MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1918 - 1927
  • [7] Multi-slice helical CT: Scan and reconstruction
    Hu, H
    [J]. MEDICAL PHYSICS, 1999, 26 (01) : 5 - 18
  • [8] Pitch dependence of longitudinal sampling and aliasing effects in multi-slice helical computed tomography (CT)
    La Rivière, PJ
    Pan, XC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (15): : 2797 - 2810
  • [9] Characterization of motion artifacts in multi-slice spiral CT
    Graf, H
    Heuschmid, M
    Küttner, A
    Kopp, AF
    Claussen, CD
    Schick, F
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (10): : 1301 - 1308
  • [10] A generalized helical reconstruction algorithm for multi-slice CT
    Hsieh, J
    Toth, TL
    Simoni, P
    Grekowicz, B
    Slack, CC
    Seidenschnur, GE
    [J]. RADIOLOGY, 2001, 221 : 217 - 217