The effect of pitch in multi-slice spiral/helical CT

被引:0
|
作者
Wang, G [1 ]
Vannier, MW [1 ]
机构
[1] Univ Iowa, Dept Radiol, Iowa City, IA 52242 USA
来源
关键词
computed tomography (CT); spiral/helical technique; multi-rows of detectors; multi-slices; data interpolation; image quality; sensitivity analysis; imaging protocol optimization;
D O I
10.1117/12.363713
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PURPOSE: To understand the effect of pitch on raw data interpolation in multi-slice spiral/helical CT, and provide guidelines for scanner design and protocol optimization. METHODS: Multi-slice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the detector collimation, and the table increment per X-ray source rotation. The pitch in multi-slice spiral CT is defined as the ratio of the table increment over the detector collimation. In parallel to the current framework for studying longitudinal image resolution, the central fan-beam rays of direct and opposite directions are considered, assuming a narrow cone-beam angle. Generally speaking, sampling in the Radon domain by the direct and opposite central rays is non-uniform along the longitudinal axis. Using a recently developed methodology for quantifying the sensitivity of signal reconstruction from non-uniformly sampled finite points, the effect of pitch on raw data interpolation is analyzed in multi-slice spiral CT. RESULTS: Unlike single-slice spiral CT, in which image quality decreases monotonically as the pitch increases, the sensitivity of raw data interpolation in multi-slice spiral CT increases in an alternating way as the pitch increases, suggesting that image quality does not decrease monotonically in this case. The most favorable pitch can be found from the sensitivity-pitch plot for any given set of multi-slice spiral CT parameters. An example for four-slice spiral CT is provided. CONCLUSION: The study on the pitch effect using the sensitivity analysis approach reveals the fundamental characteristics of raw data interpolation in multi-slice spiral CT, and gives insights into interaction between pitch and image quality. These results may be valuable for design of multi-slice spiral CT scanners and imaging protocol optimization in clinical applications.
引用
收藏
页码:116 / 127
页数:12
相关论文
共 50 条
  • [21] Isotropic high-resolution in multi-slice spiral CT
    Shechter, G
    Altman, A
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3769 - 3772
  • [22] Multi-slice spiral CT findings of tubulovillous adenoma of the duodenum
    Li, Li-Chao
    Zheng, Li-Rong
    Han, Ning
    [J]. CLINICAL IMAGING, 2022, 82 : 135 - 138
  • [23] Analytical models for multi-slice helical CT performance parameters
    Hsieh, J
    [J]. MEDICAL PHYSICS, 2003, 30 (02) : 169 - 178
  • [24] Multi-slice helical CT: Principles, imaging characteristics, and performance
    Hu, H
    He, HD
    Fox, S
    Ackelsberg, S
    Strong, G
    Seidenschnur, G
    [J]. PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 637 - 639
  • [25] Pulmonary vein varix: diagnosis with multi-slice helical CT
    E. Vanherreweghe
    H. Rigauts
    Y. Bogaerts
    L. Meeus
    [J]. European Radiology, 2000, 10 : 1315 - 1317
  • [26] Multi-slice spiral CT findings of tubulovillous adenoma of the duodenum
    Li, Li-Chao
    Zheng, Li-Rong
    Han, Ning
    [J]. Clinical Imaging, 2022, 82 : 135 - 138
  • [27] Pulmonary vein varix: diagnosis with multi-slice helical CT
    Vanherreweghe, E
    Rigauts, H
    Bogaerts, Y
    Meeus, L
    [J]. EUROPEAN RADIOLOGY, 2000, 10 (08) : 1315 - 1317
  • [28] Correction of a new type of artifact in helical multi-slice CT
    Zmora, I
    Taguchi, K
    Silver, MD
    Han, KS
    [J]. RADIOLOGY, 1998, 209P : 434 - 435
  • [29] Fourier crosstalk analysis of multi-slice and conebeam helical CT
    La Rivière, PJ
    [J]. MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 19 - 28
  • [30] Adaptive interpolation approach for multi-slice helical CT reconstruction
    Hsieh, J
    [J]. MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1876 - 1883