A frequency domain compensation scheme for multi-slice helical CT reconstruction with tilted gantry

被引:1
|
作者
Hsieh, J [1 ]
Hu, H [1 ]
机构
[1] GE Co, Med Syst, Milwaukee, WI 53201 USA
关键词
multi-slice computed tomography; tilted helical scan; tomographic reconstruction; image artifact;
D O I
10.1117/12.430998
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Multi-slice CT (MCT) is one of the most recent technical advancements in computed tomography. MCT offers high volume coverage, faster scan speed, and reduced x-ray tube loading. When combined with the helical scan mode, MCT provides even higher volume coverage as a result of the elimination of the inter-scan delays. Similar to the single slice CT, the projection data collected in MCT is inherently inconsistent.. To combat projection inconsistency, many image reconstruction algorithms were investigated and developed. Recent studies, have shown, however, that the image quality of MCT can be significantly degraded when the data is collected in a tilted helical mode. The degradation can be so severe that it is unacceptable for routine clinical usage. In this paper, we present a detailed investigation to, show that the root cause of the image quality degradation is the deviation of the reconstruction iso-center from the gantry iso-center. An analytical model is derived to establish a quantitative relationship between the iso-center shift and other system parameters. The model serves as the mathematical basis for the derivation of a frequency-domain correction algorithm. Detailed performance evaluation is provided in terms of spatial resolution, noise, computational efficiency, and image artifacts.
引用
收藏
页码:105 / 112
页数:4
相关论文
共 50 条
  • [41] Evaluation of multi-slice helical CT angiography for the assessment of peripheral artery disease
    Kreissig, R
    Knollmann, FD
    Steinkamp, HJ
    Boettcher, HD
    Ehrenstein, T
    Felix, R
    RADIOLOGY, 2000, 217 : 593 - 594
  • [42] Multi-slice helical CT: biggest pitch does not mean dosimetric bargain
    Cordoliani, YS
    JOURNAL DE RADIOLOGIE, 2000, 81 (06): : 587 - 588
  • [43] Evaluation of the performance of multi-slice CT system in non-helical scanning
    Saito, Y
    Suzuki, T
    RADIOLOGY, 1998, 209P : 285 - 285
  • [44] Reconstruction algorithm with improved efficiency and flexibility in multi-slice spiral CT
    Sun, Wenwu
    Chen, Siping
    Zhuang, Tiange
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1901 - 1904
  • [45] Radiation dose from helical CT in children: Comparison of multi-slice and single-slice protocols
    Frush, DP
    Yoshizumi, TT
    Paulson, EK
    Johnson, GA
    RADIOLOGY, 2001, 221 : 246 - 246
  • [46] A novel QA imaging performance comparison of single slice end multi-slice helical CT systems
    Blanck, CA
    Powell, GF
    Gauntt, DM
    RADIOLOGY, 2000, 217 : 313 - 313
  • [47] Dose in multi-slice spiral CT
    Spreiter, Q
    Doubrava, C
    von der Haar, T
    Flohr, T
    Schaller, S
    PHYSICA MEDICA, 2000, 16 (03) : 151 - 154
  • [48] Improvement of coronary calcification quantification with a new reconstruction algorithm and multi-slice helical CT: Theoretical considerations and phantom evaluation
    Kimura, F
    Shen, Y
    Pan, T
    Ueno, E
    Sakai, F
    Ono, Y
    RADIOLOGY, 2000, 217 : 590 - 590
  • [49] Calcification measurement with multi-slice CT
    Pan, T
    Hurley, D
    Acharya, KC
    Sasaki, K
    RADIOLOGY, 2000, 217 : 161 - 161
  • [50] Principles and applications of multi-slice CT
    Ohnesorge, B
    Flohr, T
    Schaller, S
    Klingenbeck-Regn, K
    Becker, C
    Schöpf, UJ
    Brüning, R
    Reiser, MF
    RADIOLOGE, 1999, 39 (11): : 923 - 931