Performance of the St. Jude Medical Riata Leads

被引:47
|
作者
Epstein, Andrew E. [1 ]
Baker, James H. [2 ]
Beau, Scott L. [3 ]
Deering, Thomas F. [4 ]
Greenberg, Steven M. [5 ]
Goldman, Daniel S. [6 ]
机构
[1] Univ Alabama Birmingham, Dept Med, Div Cardiovasc Dis, Birmingham, AL 35294 USA
[2] St Thomas Hosp, Nashville, TN USA
[3] Arkansas Heart Hosp, Little Rock, AR USA
[4] Piedmont Hosp, Atlanta, GA USA
[5] St Francis Hosp, Roslyn, NY USA
[6] Ctr Cardiol, Delray Beach, FL USA
关键词
Implantable cardioverter-defibrillator; Lead complications; Perforation; IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS; SURGICAL REVISION; ICD LEAD; PERFORATION; COMPLICATIONS; RECOMMENDATIONS; FAILURE;
D O I
10.1016/j.hrthm.2008.10.030
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Recent attention has been focused on the performance of high-vottage implantable cardioverter-defibrillator (ICD) Leads. Lead-related adverse events can be caused by several factors, including patient characteristics, concomitant therapies, implantation technique, access site, and lead design. Few studies have included the number of patients and the follow-up duration necessary to characterize accurately the Lead performance and the incidence of Lead-related adverse events. OBJECTIVE This study sought to define the incidence of lead-related adverse events including conductor fracture, insulation damage, perforation, and dislodgement of St. Jude Medical Riata ICD leads. METHODS Data from the Advancements in ICD Therapy, OPTIM Lead InsUlation Material (OPTIMUM), Resynchronization HemodYnamic Treatment for Heart Failure Management (RHYTHM), and Post Approval Study (PAS) registries provided data from 7,497 patients with Riata leads. Patients were followed up for a median of 22 months. Adverse events, defined as those that required Lead revision, extraction, or replacement, were recorded. RESULTS Conductor fracture occurred in 0.09%, insulation damage in 0.13%, dislodgement in 0.88%, and perforation in 0.31% of patients, respectively. CONCLUSION During more than 22 months of follow-up of over 7,000 Riata leads in 4 prospective registries and clinical trials, the incidence of tead-related adverse events including conductor fracture, insulation damage, dislodgement, and perforation necessitating lead revision, extraction, or replacement is rare.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 50 条
  • [11] Longevity Performance of St. Jude Medical ICDs at a Single Center
    Corbisiero, Raffaele
    Charlene, Pherson
    Cleary, Ellen
    Belsito, Marlene
    Muller, David
    JOURNAL OF CARDIAC FAILURE, 2015, 21 (08) : S40 - S40
  • [12] Comparison of lead failure manifestation of Biotronik Linox with St. Jude Medical Riata and Medtronic Sprint Fidelis lead
    Lam, Anna
    Buehler, Stefan
    Goulouti, Eleni
    Sweda, Romy
    Haeberlin, Andreas
    Medeiros-Domingo, Argelia
    Servatius, Helge
    Seiler, Jens
    Baldinger, Samuel
    Noti, Fabian
    Tanner, Hildegard
    Roten, Laurent
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2019, 54 (02) : 161 - 170
  • [13] St. Jude Medical Portico™ transapical technology
    Cheung, Anson
    Makkar, Raj
    Fontana, Gregory P.
    EUROINTERVENTION, 2013, 9 : S103 - S106
  • [14] Empfehlungen der Deutschen Gesellschaft für Kardiologie (Arbeitsgruppe Rhythmologie) zum Umgang mit Patienten mit ICD-Elektroden Riata® und Riata ST® der Firma St. Jude MedicalNucleus der AG Rhythmologie der Deutschen Gesellschaft für KardiologieRecommendations of the Working Group of Arrhythmias of the German Society of Cardiology on the approach to patients with Riata® and Riata ST® leads (St. Jude Medical)Nucleus of the Working Group of Arrhythmias of the German Society of Cardiology
    C.W. Israel
    D. Bänsch
    D. Böcker
    C. Butter
    J. Chun
    I. Deisenhofer
    L. Eckardt
    J.-C. Geller
    T. Hanke
    T. Klingenheben
    C. Piorkowski
    B. Schumacher
    Herzschrittmachertherapie + Elektrophysiologie, 2012, 23 (2) : 107 - 115
  • [15] Hemodynamic Performance of the St. Jude Medical Epic™ Supra Aortic Stented Valve
    Maitland, A.
    Hirsch, G. M.
    Pascoe, E. A.
    CARDIOLOGY, 2010, 115 (04) : 276 - 276
  • [16] St. Jude Medical Trifecta™ aortic valve perioperative performance in 200 patients
    Permanyer, Eduard
    Estigarribia, Arnaldo-Javier
    Ysasi, Alejandro
    Herrero, Enrique
    Semper, Omar
    Llorens, Rafael
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 17 (04) : 669 - 672
  • [17] Hemodynamic Performance of the St. Jude Medical Epic™ Supra Aortic Stented Valve
    Maitland, Andrew
    Hirsch, Gregory M.
    Pascoe, Edward A.
    JOURNAL OF HEART VALVE DISEASE, 2011, 20 (03): : 327 - 331
  • [18] Hemodynamics and early performance of the St. Jude Medical Regent™ aortic valve prosthesis
    Bach, DS
    Goldbach, M
    Sakwa, MP
    Petracek, M
    Errett, L
    Mohr, F
    JOURNAL OF HEART VALVE DISEASE, 2001, 10 (04): : 436 - 442
  • [19] Statement of the Working Group on Electrophysiological Surgery of the DGTHG on the Recommendations of the DGK (German Cardiac Society, Working Group Rhythmology) on dealing with Patients with the ICD Electrodes Riata and Riata ST from St. Jude Medical
    Osswald, B.
    Israel, C.
    Burger, H.
    Bimmel, D.
    Siebel, A.
    Schmid, M.
    Weissenberger, W.
    Markewitz, A.
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2014, 28 (01): : 5 - 7
  • [20] Timing of delayed perforation with the St. Jude Riata lead: A single-center experience and a review of the literature
    Danik, Stephan B.
    Mansour, Moussa
    Heist, E. Kevin
    Ellinor, Patrick
    Milan, David
    Singh, Jagmeet
    Das, Saumya
    Reddy, Vivek
    D'Avila, Andre
    Ruskin, Jeremy N.
    Mela, Theofanie
    HEART RHYTHM, 2008, 5 (12) : 1667 - 1672