St. Jude Medical Trifecta™ aortic valve perioperative performance in 200 patients

被引:39
|
作者
Permanyer, Eduard [1 ]
Estigarribia, Arnaldo-Javier [1 ]
Ysasi, Alejandro [2 ]
Herrero, Enrique [2 ]
Semper, Omar [1 ]
Llorens, Rafael [1 ]
机构
[1] Hospiten Rambla, Dept Cardiac Surg, Santa Cruz De Tenerife 38001, Spain
[2] Hospiten Rambla, Dept Anaesthesiol, Santa Cruz De Tenerife 38001, Spain
关键词
Aortic valve; Trifecta bioprosthesis; Mean systolic pressure gradients; Mean effective orifice area; HEMODYNAMIC PERFORMANCE; BIOPROSTHESIS; EXPERIENCE; BOVINE; REPLACEMENT; PERIMOUNT; MORTALITY; 20-YEAR;
D O I
10.1093/icvts/ivt270
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The St. Jude Medical Trifecta aortic bioprosthesis (St. Jude Medical, Inc., St. Paul, MN, USA) is a new stented pericardial tissue heart valve. The aim of the study was to evaluate the clinical and haemodynamic performance of the Trifecta bioprosthesis in the early postoperative period. From July 2010 to September 2012, a total of 200 consecutive patients underwent aortic valve replacement with the Trifecta valve in our institution. All intraoperative and postoperative data were prospectively collected. Mean EuroSCORE II was 3.98%. Echocardiography was performed at discharge in all patients. The mean age was 71.2 +/- 7.7 (range 39-89 years). Extubation in the operating theatre was successfully performed in 96% of patients. Mean hospital stay was 8.5 days. The prosthesis sizes were 19 mm (n = 33), 21 mm (n = 81), 23 mm (n = 59), 25 mm (n = 23) and 27 mm (n = 4). Mean systolic pressure gradients ranged from 9.4 mmHg (size 19 valve) to 4.8 mmHg (size 27 valve). Mean effective orifice area (EOA) ranged from 1.61 cm(2) (size 19 valve) to 2.5 cm(2) (size 27 valve). Severe mismatch (< 0.65 cm(2)/m(2)) did not occur in any patient. Of note, 99.5% of patients had mild or no aortic insufficiency at discharge. The early (30-day) mortality was 2.5% (n = 5). The Trifecta valve offers good clinical results and excellent haemodynamic performance. Special care must be taken to avoid oversizing, which can lead to difficulty in implantation and can produce gradient increases due to an excess of prosthetic leaflet tissue.
引用
收藏
页码:669 / 672
页数:4
相关论文
共 50 条
  • [1] Comprehensive Hemodynamic Evaluation and Early Performance of the St. Jude Medical Trifecta™ Aortic Valve Tissue Prosthesis
    Vorobiof, G.
    Diep, J.
    Barnes, M. J.
    Bethencourt, D. M.
    CARDIOLOGY, 2012, 121 (02) : 143 - 144
  • [2] Early Results of the Investigational St. Jude Medical Trifecta™ Pericardial Aortic Valve Bioprosthesis
    Bavaria, J. E.
    Szeto, W. Y.
    Burtch, K. E.
    Moyer, E. P.
    Morris, R. J.
    Desai, N. D.
    CARDIOLOGY, 2010, 115 (04) : 253 - 253
  • [3] St. Jude medical trifecta ™ aortic bioprosthesis - the training perspective
    Sepehripour, A. H.
    McCormack, D. J.
    Lall, K. S.
    BRITISH JOURNAL OF SURGERY, 2013, 100 : 165 - 165
  • [4] St. Jude Medical Trifecta aortic valve: results from a prospective regional multicentre registry
    Giovanni Mariscalco
    Silvia Mariani
    Samuele Bichi
    Andrea Biondi
    Andrea Blasio
    Paolo Borsani
    Fabrizio Corti
    Benedetta De Chiara
    Riccardo Gherli
    Cristian Leva
    Claudio Francesco Russo
    Giordano Tasca
    Paolo Vanelli
    Ottavio Alfieri
    Carlo Antona
    Germano Di Credico
    Giampiero Esposito
    Amando Gamba
    Luigi Martinelli
    Lorenzo Menicanti
    Giovanni Paolini
    Cesare Beghi
    Journal of Cardiothoracic Surgery, 10
  • [5] St. Jude Medical Trifecta aortic valve: results from a prospective regional multicentre registry
    Mariscalco, Giovanni
    Mariani, Silvia
    Bichi, Samuele
    Biondi, Andrea
    Blasio, Andrea
    Borsani, Paolo
    Corti, Fabrizio
    De Chiara, Benedetta
    Gherli, Riccardo
    Leva, Cristian
    Russo, Claudio Francesco
    Tasca, Giordano
    Vanelli, Paolo
    Alfieri, Ottavio
    Antona, Carlo
    Di Credico, Germano
    Esposito, Giampiero
    Gamba, Amando
    Martinelli, Luigi
    Menicanti, Lorenzo
    Paolini, Giovanni
    Beghi, Cesare
    JOURNAL OF CARDIOTHORACIC SURGERY, 2015, 10
  • [6] Comprehensive Hemodynamic Performance and Frequency of Patient-Prosthesis Mismatch of the St. Jude Medical Trifecta™ Bioprosthetic Aortic Valve
    Yadlapati, Ajay
    Diep, Jimmy
    Barnes, Mary-Jo
    Grogan, Tristan
    Bethencourt, Daniel M.
    Vorobiof, Gabriel
    JOURNAL OF HEART VALVE DISEASE, 2014, 23 (04): : 516 - 523
  • [7] Feasibility of Valve-in-Valve Procedure for Degenerated St. Jude Medical Trifecta™ Bioprosthesis
    Verhoye, Jean-Philippe
    Harmouche, Majid
    Soulami, Reda Belhaj
    Thebault, Christophe
    Boulmier, Dominique
    Leguerrier, Alain
    Anselmi, Amedeo
    JOURNAL OF HEART VALVE DISEASE, 2015, 24 (04): : 484 - 486
  • [8] Hemodynamic Performance of the St. Jude Medical Epic™ Supra Aortic Stented Valve
    Maitland, A.
    Hirsch, G. M.
    Pascoe, E. A.
    CARDIOLOGY, 2010, 115 (04) : 276 - 276
  • [9] Thrombotic Thrombocytopenic Purpura Following Aortic Valve Replacement with St. Jude Medical Trifecta Bio-Prosthesis
    D'Alessio, Andrea
    Verdichizzo, Danilo
    Falconieri, Fabio
    Keiralla, Amar
    Abramik, Joanna
    Kasimis, Georgios
    Krasopoulos, George
    CARDIOLOGY RESEARCH, 2018, 9 (06) : 392 - 394
  • [10] Early and mid-term haemodynamic performance and clinical outcomes of St. Jude Medical Trifecta™ valve
    Raimundo, Renata
    Moreira, Soraia
    Saraiva, Francisca
    Cerqueira, Rui J.
    Teixeira, Pedro
    Salgueiro, Elson
    Lourenco, Andre
    Amorim, Mario J.
    Almeida, Jorge
    Pinho, Paulo
    Leite-Moreira, Adelino F.
    JOURNAL OF THORACIC DISEASE, 2018, 10 (02) : 889 - 898