Reverse Optic Capture of the Single-Piece Acrylic Intraocular Lens in Eyes With Posterior Capsule Rupture

被引:9
|
作者
Jones, Jason J. [1 ]
Oetting, Thomas A. [2 ]
Rogers, Gina M. [2 ]
Jin, George J. C. [1 ,3 ]
机构
[1] Jones Eye Clin & Surg Ctr, Sioux City, IA 51104 USA
[2] Univ Iowa, Dept Ophthalmol, Iowa City, IA 52242 USA
[3] Univ Utah, Dept Ophthalmol & Visual Sci, Salt Lake City, UT USA
关键词
SURGICAL-MANAGEMENT; SULCUS PLACEMENT; TERM OUTCOMES; IMPLANTATION; CATARACT; PHACOEMULSIFICATION; CHAMBER; CAPSULORHEXIS; ABSENCE; POWER;
D O I
10.3928/15428877-20120830-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To evaluate the clinical results of reverse optic capture (ROC) with single-piece posterior chamber intraocular lenses (PC-IOLs) in cases of phacoemulsification cataract and IOL surgery with posterior capsular rupture. PATIENTS AND METHODS: Preoperative diagnosis, intraoperative events, surgical parameters, intraoperative and postoperative complications, and preoperative and postoperative visual acuity and refraction of 16 eyes that underwent ROC were reviewed and analyzed. The fellow eye of 12 patients undergoing uneventful phacoemulsification without optic capture served as the control group. RESULTS: Over a mean of 19 months' follow-up, 94% of eyes in the ROC group and 92% in the control group achieved a best-corrected visual acuity of 20/25 or better. Ninety-four percent of eyes in the ROC group and 100% in the control group had postoperative spherical equivalent +/- 1.00 D of the intended refraction. Refraction was stable between 1 month and final follow-up in both groups. In all eyes with ROC, the IOL remained well centered with a securely captured optic. There were no vision-threatening complications throughout the follow-up. CONCLUSION: The comparable outcomes in both groups suggests that optic capture of a single-piece acrylic IOL through an anterior capsulorhexis merits consideration for IOL placement in selected cases of insufficient posterior capsule support. [Ophthalmic Surg Lasers Imaging 2012; 43: 480-488.]
引用
收藏
页码:480 / 488
页数:9
相关论文
共 50 条
  • [21] Implantation of foldable intraocular lens with anterior optic capture in isolated posterior capsule rupture
    Pushker, N
    Sony, P
    Khokhar, S
    Vardhan, P
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (07): : 1457 - 1458
  • [22] Surgical technique for suture fixation of a single-piece hydrophilic acrylic intraocular lens in the absence of capsule support
    Oh, Hyun-Sub
    Chu, Young-Kwang
    Kwon, Oh-Woong
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (06): : 962 - 965
  • [23] Transscleral fixation of a single-piece hydrophilic foldable acrylic intraocular lens
    Taskapili, Muhittin
    Gulkilik, Gokhan
    Engin, Gunay
    Kocabora, Mehmet Selim
    Yilmazli, Cemil
    Ozsutcu, Mustafa
    Kucuksahin, Hasan
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2007, 42 (02): : 256 - 261
  • [24] Comparison of stability between a modular intraocular lens system and a single-piece hydrophobic acrylic intraocular lens
    SooHoo, Jeffrey R.
    Lane, Stephen S.
    Cionni, Robert J.
    Berdahl, John P.
    Sussman, Glenn R.
    Kahook, Malik Y.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (12): : 1821 - 1825
  • [25] Pattern of posterior capsule opacification models 2 years postoperatively with 2 single-piece acrylic intraocular lenses
    Nixon, Don R.
    Woodcock, Michael G.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06): : 929 - 934
  • [26] Breakage of the haptic of a single-piece acrylic intraocular lens after transscleral fixation
    Choi, Suk Kyue
    Kim, Jin Hyoung
    Lee, Doh
    Lee, Jong Hyun
    ACTA OPHTHALMOLOGICA, 2010, 88 (08) : e346 - e347
  • [27] Implantation of a single-piece, hydrophilic, acrylic, minus-power foldable posterior chamber intraocular lens in a rabbit model - Clinicopathologic study of posterior capsule opacification
    Vargas, LG
    Izak, AM
    Apple, DJ
    Werner, L
    Pandey, SK
    Trivedi, RH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (08): : 1613 - 1620
  • [28] Forceps-induced cracking of a single-piece acrylic foldable intraocular lens
    Balasubramanya, R
    Rani, A
    Dada, T
    OPHTHALMIC SURGERY LASERS & IMAGING, 2003, 34 (04): : 306 - 307
  • [29] Rotational Stability of a Single-Piece Toric Acrylic Intraocular Lens: A Pilot Study
    Hirnschall, Nino
    Maedel, Sophie
    Weber, Maria
    Findl, Oliver
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (02) : 405 - 411
  • [30] Haptic Breakage after Transscleral Fixation of a Single-Piece Acrylic Intraocular Lens
    Tanaka, Hiroki
    Fujinami, Kaoru
    Watanabe, Ken
    Noda, Toru
    Akiyama, Kunihiko
    CASE REPORTS IN OPHTHALMOLOGY, 2014, 5 (02): : 212 - 216