Surgical technique for suture fixation of a single-piece hydrophilic acrylic intraocular lens in the absence of capsule support

被引:15
|
作者
Oh, Hyun-Sub
Chu, Young-Kwang
Kwon, Oh-Woong
机构
[1] Yonsei Univ, Coll Med, Dept Ophthalmol, Inst Vis Res, Seoul 120752, South Korea
[2] Siloam Eye Hosp, Seoul, South Korea
来源
关键词
D O I
10.1016/j.jcrs.2006.09.050
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We present a new intraocular lens (IOL) fixation technique that reduces the presence of intraocular knots and eliminates the need for scleral flaps while attaining excellent central positioning of the IOL. It also provides rapid visual rehabilitation from the insertion of a foldable IOL through a small corneal incision. This single-loop suture technique is an easy, convenient, and practical procedure, with minimum complications in the treatment of aphakia and the management of cataract surgery in eyes without capsular support.
引用
收藏
页码:962 / 965
页数:4
相关论文
共 50 条
  • [1] Surgical technique for suture fixation of an acrylic intraocular lens in the absence of capsule support
    Stutzman, RD
    Stark, WJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (09): : 1658 - 1662
  • [2] Transscleral fixation of a single-piece hydrophilic foldable acrylic intraocular lens
    Taskapili, Muhittin
    Gulkilik, Gokhan
    Engin, Gunay
    Kocabora, Mehmet Selim
    Yilmazli, Cemil
    Ozsutcu, Mustafa
    Kucuksahin, Hasan
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2007, 42 (02): : 256 - 261
  • [3] Breakage of the haptic of a single-piece acrylic intraocular lens after transscleral fixation
    Choi, Suk Kyue
    Kim, Jin Hyoung
    Lee, Doh
    Lee, Jong Hyun
    [J]. ACTA OPHTHALMOLOGICA, 2010, 88 (08) : e346 - e347
  • [4] Haptic Breakage after Transscleral Fixation of a Single-Piece Acrylic Intraocular Lens
    Tanaka, Hiroki
    Fujinami, Kaoru
    Watanabe, Ken
    Noda, Toru
    Akiyama, Kunihiko
    [J]. CASE REPORTS IN OPHTHALMOLOGY, 2014, 5 (02): : 212 - 216
  • [5] Single-piece acrylic intraocular lens in pediatric cataracts
    Edelson, C
    Dureau, P
    Adjadj, E
    Caputo, G
    de Meux, PD
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U165 - U165
  • [6] Single-piece acrylic intraocular lens implantation in children
    Trivedi, RH
    Wilson, ME
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (09): : 1738 - 1743
  • [7] Small-incision 4-point scleral suture fixation of a foldable hydrophilic acrylic intraocular lens in the absence of capsule support
    Terveen, Daniel C.
    Fram, Nicole R.
    Ayres, Brandon
    Berdahl, John P.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (02): : 211 - 216
  • [8] Single-piece acrylic intraocular lens implantation in children
    Sony, P
    Khokhar, S
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (09): : 1818 - 1819
  • [9] Suture-guided sulcus implantation of a single-piece foldable acrylic intraocular lens after posterior capsule rupture
    Sethi, Harinder Singh
    Naik, Mayuresh P.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (03): : 309 - 311
  • [10] Effect of the optic size of a single-piece acrylic intraocular lens on posterior capsule opacification
    Nishi, O
    Nishi, K
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (02): : 348 - 353