Reverse Optic Capture of the Single-Piece Acrylic Intraocular Lens in Eyes With Posterior Capsule Rupture

被引:9
|
作者
Jones, Jason J. [1 ]
Oetting, Thomas A. [2 ]
Rogers, Gina M. [2 ]
Jin, George J. C. [1 ,3 ]
机构
[1] Jones Eye Clin & Surg Ctr, Sioux City, IA 51104 USA
[2] Univ Iowa, Dept Ophthalmol, Iowa City, IA 52242 USA
[3] Univ Utah, Dept Ophthalmol & Visual Sci, Salt Lake City, UT USA
关键词
SURGICAL-MANAGEMENT; SULCUS PLACEMENT; TERM OUTCOMES; IMPLANTATION; CATARACT; PHACOEMULSIFICATION; CHAMBER; CAPSULORHEXIS; ABSENCE; POWER;
D O I
10.3928/15428877-20120830-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To evaluate the clinical results of reverse optic capture (ROC) with single-piece posterior chamber intraocular lenses (PC-IOLs) in cases of phacoemulsification cataract and IOL surgery with posterior capsular rupture. PATIENTS AND METHODS: Preoperative diagnosis, intraoperative events, surgical parameters, intraoperative and postoperative complications, and preoperative and postoperative visual acuity and refraction of 16 eyes that underwent ROC were reviewed and analyzed. The fellow eye of 12 patients undergoing uneventful phacoemulsification without optic capture served as the control group. RESULTS: Over a mean of 19 months' follow-up, 94% of eyes in the ROC group and 92% in the control group achieved a best-corrected visual acuity of 20/25 or better. Ninety-four percent of eyes in the ROC group and 100% in the control group had postoperative spherical equivalent +/- 1.00 D of the intended refraction. Refraction was stable between 1 month and final follow-up in both groups. In all eyes with ROC, the IOL remained well centered with a securely captured optic. There were no vision-threatening complications throughout the follow-up. CONCLUSION: The comparable outcomes in both groups suggests that optic capture of a single-piece acrylic IOL through an anterior capsulorhexis merits consideration for IOL placement in selected cases of insufficient posterior capsule support. [Ophthalmic Surg Lasers Imaging 2012; 43: 480-488.]
引用
收藏
页码:480 / 488
页数:9
相关论文
共 50 条
  • [31] Sulcus implantation of a 3-piece, 6.0 mm optic, hydrophobic foldable acrylic intraocular lens in phacoemulsification complicated by posterior capsule rupture
    Brazitikos, PD
    Balidis, MO
    Tranos, P
    Androudi, S
    Papadopoulos, NT
    Tsinopoulos, IT
    Karabatakis, V
    Stangos, NT
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (09): : 1618 - 1622
  • [32] Bent haptic of a single-piece AcrySof intraocular lens from capsule contraction
    Titiyal, JS
    Sinha, R
    Verma, K
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (08): : 1812 - 1813
  • [33] Comparison of sulcus implantation of single-piece hydrophilic foldable acrylic and polymethyl methacrylate intraocular lenses in eyes with posterior capsule tear during phacoemulsification surgery
    Taskapili, M.
    Gulkilik, G.
    Kocabora, M. S.
    Ozsutcu, M.
    Yilmazli, C.
    Kaya, G.
    Kucuksahin, H.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2007, 17 (04) : 595 - 600
  • [34] Intracapsular implantation of the single-piece AcrySof intraocular lens in the posterior capsular tears
    Nagahara, M
    Saitou, H
    Mori, Y
    Hirota, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [35] Glistenings in the single-piece, hydrophobic, acrylic intraocular lenses
    Waite, Aaron
    Faulkner, Nathan
    Olson, Randall J.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (01) : 143 - 144
  • [36] Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification
    Buehl, W
    Findl, O
    Menapace, R
    Rainer, G
    Sacu, S
    Kiss, B
    Petternel, V
    Georgopoulos, M
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (07): : 1105 - 1111
  • [37] Prospective evaluation of posterior capsule opacification in myopic eyes 4 years after implantation of a single-piece acrylic IOL
    Vasavada, Abhay R.
    Shah, Alpesh
    Raj, Shetal M.
    Praveen, Mamidipudi R.
    Shah, Gauri D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (09): : 1532 - 1539
  • [38] Early opacification of a single-piece hydrophobic acrylic intraocular lens after a triple procedure
    Iwase, Takeshi
    Sugiyama, Kazuhisa
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (02): : 329 - 332
  • [39] Glistening Formation on a Single-Piece Prehydrated Hydrophobic Acrylic Intraocular Lens in a Diabetic Patient
    Kang, Su-Yeon
    Eom, Youngsub
    Rhim, Jay Won
    Song, Jong Suk
    Kim, Hyo Myung
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (10) : 710 - 712
  • [40] Effect of a single-piece aspheric hydrophobic acrylic intraocular lens design on centration and rotation
    Roshdy, Maged M.
    Riad, Riad F.
    Morkos, Fathy F.
    Hassouna, Abdallah K.
    Wahba, Sherein S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (03): : 408 - 413