AN INVESTIGATION INTO CT RADIATION DOSE VARIATIONS FOR HEAD EXAMINATIONS ON MATCHED EQUIPMENT

被引:4
|
作者
Zarb, Francis [1 ]
Foley, Shane [2 ]
Holm, Susanne [3 ]
Toomey, Rachel [2 ]
Evanoff, Michael G. [4 ]
Rainford, Louise [2 ]
机构
[1] Univ Malta, Dept Radiog, Fac Hlth Sci, Msida, Malta
[2] Univ Coll Dublin, Sch Med, Diagnost Imaging, Dublin 4, Ireland
[3] Univ Coll Lillebaelt, CONRAD Radiog Res Ctr, Blangstedgaardsvej 4, DK-5220 Odense, Denmark
[4] Amer Board Radiol, 5441 East Williams Blvd,Suite 200, Tucson, AZ USA
关键词
DIAGNOSTIC REFERENCE LEVELS; IMAGE QUALITY; CHEST CT; COMPUTED-TOMOGRAPHY; IONIZING-RADIATION; VGC ANALYSIS; EXPOSURE; OPTIMIZATION; PERFORMANCE; MANAGEMENT;
D O I
10.1093/rpd/ncv549
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigated radiation dose and image quality differences for computed tomography (CT) head examinations across centres with matched CT equipment. Radiation dose records and imaging protocols currently employed across three European university teaching hospitals were collated, compared and coded as Centres A, B and C from specification matched CT equipment models. Patient scans (n = 40) obtained from Centres A and C were evaluated for image quality, based on the visualisation of Commission of European Community (CEC) image quality criteria using visual grading characteristic (VGC) analysis, where American Board of Radiology examiners (n 5 11) stated their confidence in identifying anatomical criteria. Mean doses in terms of CT dose index (CTDIvol-mGy) and dose length product (DLP-mGy cm) were as follows: Centre A-33.12 mGy and 461.45 mGy cm; Centre B -101 mGy (base)/32 mGy (cerebrum) and 762 mGy cm and Centre C-71.98 mGy and 1047.26 mGy cm, showing a significant difference (p <= 0.05) in DLP across centres. VGC analysis indicated better visualisation of CEC criteria on Centre C images (VGC(AUC) 0.225). All three imaging protocols are routinely used clinically, and image quality is acceptable in each centre. Clinical centres with identical model CT scanners have variously customised their protocols achieving a range of dose savings and still resulting in clinically acceptable image quality.
引用
收藏
页码:466 / 474
页数:9
相关论文
共 50 条
  • [41] Assessment and comparison of radiation dose and image quality in multi-detector CT scanners in non-contrast head and neck examinations
    Khoramian, Daryoush
    Sistani, Soroush
    Firouzjah, Razzagh Abedi
    POLISH JOURNAL OF RADIOLOGY, 2019, 84 : E61 - E67
  • [42] Evaluation of radiation dose and radiation-induced cancer risk associated with routine CT scan examinations
    Bagherzadeh, Saeed
    Mirderikvand, Afsaneh
    Mohammadsharifi, Ali
    RADIATION PHYSICS AND CHEMISTRY, 2024, 217
  • [43] Evaluation of radiation dose reduction in head CT using the half-dose method
    Nakai, Yoshitomo
    Miyazaki, Osamu
    Kitamura, Masayuki
    Imai, Rumi
    Okamoto, Reiko
    Tsutsumi, Yoshiyuki
    Miyasaka, Mikiko
    Ogiwara, Hideki
    Miura, Hiroshi
    Yamada, Kei
    Nosaka, Shunsuke
    JAPANESE JOURNAL OF RADIOLOGY, 2023, 41 (08) : 872 - 881
  • [44] Evaluation of radiation dose reduction in head CT using the half-dose method
    Yoshitomo Nakai
    Osamu Miyazaki
    Masayuki Kitamura
    Rumi Imai
    Reiko Okamoto
    Yoshiyuki Tsutsumi
    Mikiko Miyasaka
    Hideki Ogiwara
    Hiroshi Miura
    Kei Yamada
    Shunsuke Nosaka
    Japanese Journal of Radiology, 2023, 41 : 872 - 881
  • [45] MEASUREMENT OF INTERNAL RADIATION DOSE DISTRIBUTION IN CT EXAMINATIONS USING POLYETHYLENE TEREPHTHALATE RESIN
    Yamauchi-Kawaura, C.
    Yamamoto, S.
    Fujii, K.
    Komori, M.
    Yamauchi, M.
    Ohzawa, N.
    Kozuka, M.
    Suga, N.
    Ito, N.
    Fukuyama, A.
    RADIATION PROTECTION DOSIMETRY, 2018, 181 (04) : 303 - 309
  • [46] Radiation doses from low-dose CT scans in SPECT/CT and PET/CT examinations: A survey in Germany
    Rinscheid, Andreas
    Janzen, Tilman
    Alikhani, Babak
    Beer, Ambros J.
    Braune, Anja
    Eberhardt, Nina
    Fechner, Diana
    Foerster, Stefan
    Freesmeyer, Martin
    Furth, Christian
    Grunert, Michael
    Hellwig, Dirk
    Costa, Pedro Fragoso
    Kuehnel, Christian
    Lange, Catharina
    Linke, Rainer
    Razlaw, Natalia
    Sack, Tobias
    Schmidt, Daniel
    Schuetze, Christina
    Starke, Alexander
    Tondera, Liane
    Wengenmair, Hermann
    Zoephel, Klaus
    Burchert, Wolfgang
    Lapa, Constantin
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2022, 61 (04): : 294 - 300
  • [47] PATIENT-SIZE-DEPENDENT RADIATION DOSE OPTIMISATION TECHNIQUE FOR ABDOMINAL CT EXAMINATIONS
    Ngaile, J. E.
    Msaki, P.
    Kazema, R.
    RADIATION PROTECTION DOSIMETRY, 2012, 148 (02) : 189 - 201
  • [48] Effectiveness of the air-gap method for reducing radiation dose in neonate CT examinations
    Masuda, Takanori
    Funama, Yoshinori
    Nakaura, Takeshi
    Sato, Tomoyasu
    Oku, Takayuki
    Ono, Atsushi
    Awai, Kazuo
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2025, 18 (01) : 293 - 299
  • [49] Introduction and evaluation of size-specific DLP for radiation dose estimation in CT examinations
    Dendo, Yutaka
    Abe, Keisuke
    Onodera, Shu
    Kayano, Shingo
    Ota, Hideki
    Takase, Kei
    JOURNAL OF RADIOLOGICAL PROTECTION, 2024, 44 (04)
  • [50] Breast radiation dose equivalent and cancer risk estimation during PET/ CT examinations
    Jambi, Layal
    Alkhorayef, Mohammed
    Almuwanis, Mohammed
    Sulieman, Abdelmoneim
    RADIATION PHYSICS AND CHEMISTRY, 2024, 215