Evaluation of radiation dose reduction in head CT using the half-dose method

被引:4
|
作者
Nakai, Yoshitomo [1 ,2 ]
Miyazaki, Osamu [1 ]
Kitamura, Masayuki [1 ]
Imai, Rumi [1 ]
Okamoto, Reiko [1 ]
Tsutsumi, Yoshiyuki [1 ]
Miyasaka, Mikiko [1 ]
Ogiwara, Hideki [3 ]
Miura, Hiroshi [4 ]
Yamada, Kei [2 ]
Nosaka, Shunsuke [1 ]
机构
[1] Natl Ctr Child Hlth & Dev, Dept Radiol, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
[2] Kyoto Prefectural Univ Med, Dept Radiol, 465 Kawaramachi Hirokoji Kamigyo Ku, Kyoto, Japan
[3] Natl Ctr Child Hlth & Dev, Div Neurosurg, 2-10-1 Okura,Setagaya Ku, Tokyo, Japan
[4] Kyoto Daini Hosp, Dept Radiol Japanese Red Cross Soc, 355-5 Haruobicho Kamanza Dori Marutamachi Agaru,Ka, Kyoto, Japan
关键词
Computed tomography; CT dose index volume; Dose-length product; Hydrocephalus; Craniosynostosis; EXPOSURE; CHILDREN; RISK;
D O I
10.1007/s11604-023-01410-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe present study introduced the half-dose method (HDM), which halves the radiation dose for conventional head computed tomography (CT), for postoperative hydrocephalus and follow-up for craniosynostosis at a children's hospital. This study aimed to evaluate the contribution of selective head CT scanning optimization towards the overall reduction of radiation exposure.Materials and methodsWe retrospectively assessed 1227 and 1352 head CT examinations acquired before and after the introduction of the HDM, respectively, in children aged 0-15 years. The radiation exposure was evaluated using the CT dose index volume (CTDI-vol), dose-length product (DLP), rate of HDM introduction, and effect of reducing in-hospital radiation dose before and after the introduction of the HDM. For an objective evaluation of the image quality, head CT scans acquired with HDM and full-dose method (FDM) were randomly selected, and the image noise standard deviation (SD) was measured for each scan. In addition, some HDM images were randomly selected and independently reviewed by two radiologists.ResultsThe HDM was introduced in 27.9% of all head CTs. The mean CTDI-vol of all head CTs was 21.5 +/- 6.9 mGy after the introduction, a 14.9% reduction. The mean DLP was 418.4 +/- 152.9 mGy.cm after the introduction, a 17.2% reduction. Compared to the FDM images, the noise SD of the HDM ones worsened by almost 0.9; however, none of the images were difficult or impossible to evaluate.ConclusionThe HDM yielded diagnostically acceptable images. In addition, a change in protocol for only two diseases successfully reduced the patients' overall radiation exposure by approximately 15%. Introducing and optimizing the HDM for frequently performed target diseases will be useful in reducing the exposure dose for the hospital's patient population.
引用
收藏
页码:872 / 881
页数:10
相关论文
共 50 条
  • [1] Evaluation of radiation dose reduction in head CT using the half-dose method
    Yoshitomo Nakai
    Osamu Miyazaki
    Masayuki Kitamura
    Rumi Imai
    Reiko Okamoto
    Yoshiyuki Tsutsumi
    Mikiko Miyasaka
    Hideki Ogiwara
    Hiroshi Miura
    Kei Yamada
    Shunsuke Nosaka
    Japanese Journal of Radiology, 2023, 41 : 872 - 881
  • [2] HALF-DOSE ZIDOVUDINE
    DETRUCHIS, P
    SALMON, D
    MATHERON, S
    JELASKO, P
    ROZENBAUM, W
    LEPORT, C
    LANCET, 1991, 337 (8749): : 1109 - 1109
  • [3] Pilot Study of Radiation Dose Reduction for Pediatric Head CT in Evaluation of Ventricular Size
    Gabriel, S.
    Eckel, L. J.
    DeLone, D. R.
    Krecke, K. N.
    Luetmer, P. H.
    McCollough, C. H.
    Fletcher, J. G.
    Yu, L.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (12) : 2237 - 2242
  • [4] Clinical application of radiation dose reduction for head and neck CT
    Yabuuchi, Hidetake
    Kamitani, Takeshi
    Sagiyama, Koji
    Yamasaki, Yuzo
    Matsuura, Yuko
    Hino, Takuya
    Tsutsui, Soichiro
    Kondo, Masatoshi
    Shirasaka, Takashi
    Honda, Hiroshi
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 107 : 209 - 215
  • [5] Radiation dose reduction by using low dose CT protocol of thorax
    Ramac, J. Popic
    Knezevic, Z.
    Hebrang, A.
    Kristo, D. Radic
    Vidjak, V.
    Slavica, M.
    Ranogajec-Komor, M.
    RADIATION MEASUREMENTS, 2013, 55 : 46 - 50
  • [6] Radiation dose reduction in multidetector CT in fracture evaluation
    Yi, Jung Woo
    Park, Hee Jin
    Lee, So Yeon
    Rho, Myung Ho
    Hong, Hyun Pyo
    Choi, Yoon Jung
    Kim, Mi Sung
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1077):
  • [7] Reduction of CT radiation dose in PET-CT: evaluation of low dose CT scan protocols
    Palimieri, A.
    Bertolini, V.
    COla, S.
    Piccagli, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S777 - S777
  • [8] EVALUATION OF HALF-DOSE VERSUS FULL-DOSE ALTEPLASE FOR TREATMENT OF PULMONARY EMBOLISM
    Kiser, Tyree
    Burnham, Ellen
    Clark, Brendan
    Ho, Michael
    Moss, Marc
    Vandivier, R.
    CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [9] Half-dose WBR MIBG cardiac SPECT: clinical evaluation of resolution recovery method
    Pena, H.
    Guilhermina, G.
    Wilk, M.
    Srour, Y.
    Godinho, F.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A38 - A38
  • [10] Comparison of standard-dose and half-dose dual-source abdominopelvic CT scans for evaluation of acute abdominal pain
    Lee, Ki Hyun
    Shim, Young Sup
    Park, So Hyun
    Park, Seong Ho
    Choi, Seung Joon
    Pak, Seong Yong
    Cheong, Hyunhee