Collimator design for a multipinhole brain SPECT insert for MRI

被引:6
|
作者
Van Audenhaege, Karen [1 ]
Van Holen, Roel [1 ]
Vanhove, Christian [1 ]
Vandenberghe, Stefaan [1 ]
机构
[1] Ghent Univ iMinds Med IT, MEDISIP IBiTech, Dept Elect & Informat Syst, B-9000 Ghent, Belgium
基金
欧盟第七框架计划;
关键词
SPECT; collimator; production; single photon emission computed tomography; optimization; HIGH-RESOLUTION SPECT; SYSTEM; PET; SIMULATION; DETECTOR; MODALITY; COMPACT; IMAGES;
D O I
10.1118/1.4934371
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Brain single photon emission computed tomography (SPECT) imaging is an important clinical tool, with unique tracers for studying neurological diseases. Nowadays, most commercial SPECT systems are combined with x-ray computed tomography (CT) in so-called SPECT/CT systems to obtain an anatomical background for the functional information. However, while CT images have a high spatial resolution, they have a low soft-tissue contrast, which is an important disadvantage for brain imaging. Magnetic resonance imaging (MRI), on the other hand, has a very high soft-tissue contrast and does not involve extra ionizing radiation. Therefore, the authors designed a brain SPECT insert that can operate inside a clinical MRI. Methods: The authors designed and simulated a compact stationary multipinhole SPECT insert based on digital silicon photomultiplier detector modules, which have shown to be MR-compatible and have an excellent intrinsic resolution (0.5 mm) when combined with a monolithic 2 mm thick LYSO crystal. First, the authors optimized the different parameters of the SPECT system to maximize sensitivity for a given target resolution of 7.2 mm in the center of the field-of-view, given the spatial constraints of the MR system. Second, the authors performed noiseless simulations of two multipinhole configurations to evaluate sampling and reconstructed resolution. Finally, the authors performed Monte Carlo simulations and compared the SPECT insert with a clinical system with ultrahigh-resolution (UHR) fan beam collimators, based on contrast-to-noise ratio and a visual comparison of a Hoffman phantom with a 9 mm cold lesion. Results: The optimization resulted in a stationary multipinhole system with a collimator radius of 150.2 mm and a detector radius of 172.67 mm, which corresponds to four rings of 34 diSPM detector modules. This allows the authors to include eight rings of 24 pinholes, which results in a system volume sensitivity of 395 cps/MBq. Noiseless simulations show sufficient axial sampling (in a Defrise phantom) and a reconstructed resolution of 5.0 mm (in a cold-rod phantom). The authors compared the 24-pinhole setup with a 34-pinhole system (with the same detector radius but a collimator radius of 156.63 mm) and found that 34 pinholes result in better uniformity but a worse reconstruction of the cold-rod phantom. The authors also compared the 24-pinhole system with a clinical triple-head UHR fan beam system based on contrast-to-noise ratio and found that the 24-pinhole setup performs better for the 6 mm hot and the 16 mm cold lesions and worse for the 8 and 10 mm hot lesions. Finally, the authors reconstructed noisy projection data of a Hoffman phantom with a 9 mm cold lesion and found that the lesion was slightly better visible on the multipinhole image compared to the fan beam image. Conclusions: The authors have optimized a stationary multipinhole SPECT insert for MRI and showed the feasibility of doing brain SPECT imaging inside a MRI with an image quality similar to the best clinical SPECT systems available. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:6679 / 6689
页数:11
相关论文
共 50 条
  • [31] AN ASTIGMATIC COLLIMATOR FOR HIGH-SENSITIVITY SPECT OF THE BRAIN
    HAWMAN, EG
    HSIEH, J
    JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (06) : 930 - 930
  • [32] Design and performance evaluation of a 20-aperture multipinhole collimator for myocardial perfusion imaging applications
    Bowen, Jason D.
    Huang, Qiu
    Ellin, Justin R.
    Lee, Tzu-Cheng
    Shrestha, Uttam
    Gullberg, Grant T.
    Seo, Youngho
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (20): : 7209 - 7226
  • [33] Noise Propagation in Multipinhole SPECT Calibration
    Vunckx, Kathleen
    Zhou, Lin
    Nuyts, Johan
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3166 - 3172
  • [34] Shielding Requirements of a SPECT Insert for Installation in a PET/MRI System
    Salvado, Debora
    Erlandsson, Kjell
    Hutton, Brian F.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [35] Development of a Practical Calibration Procedure for a Clinical SPECT/MRI System Using a Single INSERT Prototype Detector and Multimini Slit-Slat Collimator
    Salvado, Debora
    Erlandsson, Kjell
    Occhipinti, Michele
    Fiorini, Carlo
    Willems, Jurgen
    van Mullekom, Pieter
    Papp, Zoltan
    Czeller, Miklos
    Nagy, Kalman
    Hutton, Brian F.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (04) : 380 - 386
  • [36] Characterization of the Detection Module of the INSERT SPECT/MRI Clinical System
    Occhipinti, M.
    Carminati, M.
    Busca, P.
    Butt, A. D.
    Montagnani, G. L.
    Trigilio, P.
    Piemonte, C.
    Ferri, A.
    Gola, A.
    Bukki, T.
    Czeller, M.
    Nyitrai, Z.
    Papp, Z.
    Nagy, K.
    Fiorini, C.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (06) : 554 - 563
  • [37] Design optimization and evaluation of a human brain SPECT-MRI insert based on high-resolution detectors and slit-slat collimators
    Erlandsson, Kjell
    Salvado, Debora
    Bousse, Alexandre
    Hutton, Brian F.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [38] Design considerations for INSERT: A new multi-modality SPECT/MRI system for preclinical and clinical imaging
    Erlandsson, Kjell
    Busca, Paolo
    Bukki, Tamas
    Gola, Alberto
    Salvado, Debora
    Butt, Arslan
    Nemeth, Gabor
    Piemonte, Claudio
    Hutton, Brian
    Fiorini, Carlo
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [39] Design considerations for INSERT: A new multi-modality SPECT/MRI system for preclinical and clinical imaging
    Erlandsson, Kjell
    Busca, Paolo
    Bukki, Tamas
    Gola, Alberto
    Salvado, Debora
    Butt, Arslan
    Nemeth, Gabor
    Piemonte, Claudio
    Hutton, Brian
    Fiorini, Carlo
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [40] A Voxel-Driven System Matrix Design for Multipinhole SPECT with Overlapping Projection
    Huang, Po-Chia
    Hsiao, Ing-Tsung
    Lin, Kurt M.
    Chou, Wen-Tsai
    Hsu, Ching-Han
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3924 - +