Noise Propagation in Multipinhole SPECT Calibration

被引:1
|
作者
Vunckx, Kathleen [1 ]
Zhou, Lin [1 ]
Nuyts, Johan [1 ]
机构
[1] Katholieke Univ Leuven, Dept Nucl Med, B-3000 Louvain, Belgium
关键词
GEOMETRICAL CALIBRATION; PINHOLE SPECT; DESIGN;
D O I
10.1109/NSSMIC.2009.5401695
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It has been shown previously that multipinhole single photon emission computed tomography (SPECT) calibration only requires a two-point source measurement, without knowledge of the distance between them, to uniquely determine the camera geometry. In this work, we studied how this method propagates measurement noise into errors on the estimated calibration parameters, which in turn will degrade the reconstruction image quality. Furthermore, the effect on the calibration and reconstruction accuracy of fixing either the inter-point or the inter-pinhole distance during calibration is assessed. As expected, including information about the distance between the point sources improved the robustness of the calibration against measurement noise. In addition, it was found that similar robustness and even a superior spatial resolution can be obtained by fixing the distance(s) between the pinhole apertures instead of fixing those between the point sources. Finally, optimal two-point source configurations were determined for calibrating our newly-designed 7-pinhole SPECT system for limited field of view mouse imaging while fixing the inter-pinhole distances.
引用
收藏
页码:3166 / 3172
页数:7
相关论文
共 50 条
  • [1] Detached multipinhole small animal SPECT device with real-time calibration
    DiFilippo, Frank P.
    Riffe, Matthew J.
    Harsch, Kelley M.
    McCabe, N. Patrick
    Heston, Warren D.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2605 - 2612
  • [2] Design of multipinhole collimators for small animal SPECT
    Smith, MF
    Meikle, SR
    Majewski, S
    Weisenberger, AG
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2291 - 2295
  • [3] In vivo multipinhole helical SPECT of a mouse thyroid
    Qian, Jianguo
    Blue, R. Eric
    Bradley, Eric L.
    Majewski, Stan
    Saba, Margaret S.
    Schworer, Stephen
    Smith, Mark F.
    Weisenberger, Andrew G.
    Welsh, Robert E.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3376 - +
  • [4] Slat collimated multipinhole human brain SPECT
    De Smet, J.
    Van Holen, R.
    Staelens, S.
    Vandenberghe, S.
    Lemahieu, I.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3309 - 3310
  • [5] Revolving Multipinhole SPECT for Small Animal Imaging
    Bal, Girish
    Acton, Paul D.
    Jansen, Floris
    Hasegawa, Bruce H.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4850 - +
  • [6] Theoretical Bounds and System Design for Multipinhole SPECT
    Nillius, Peter
    Danielsson, Mats
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (07) : 1390 - 1400
  • [7] A novel approach to multipinhole SPECT for myocardial perfusion Imaging
    Funk, T
    Kirch, DL
    Koss, JE
    Botvinick, E
    Hasegawa, BH
    JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (04) : 595 - 602
  • [8] Performance evaluation of a multipinhole small animal SPECT system
    Meikle, SR
    Kench, P
    Wojcik, R
    Smith, MF
    Weisenberger, AG
    Majewski, S
    Lerch, M
    Rosenfeld, AB
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1988 - 1992
  • [9] High-resolution SPECT using multipinhole collimation
    Schramm, NU
    Ebel, G
    Engeland, U
    Schurrat, T
    Béhé, M
    Behr, TM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) : 315 - 320
  • [10] Collimator design for a multipinhole brain SPECT insert for MRI
    Van Audenhaege, Karen
    Van Holen, Roel
    Vanhove, Christian
    Vandenberghe, Stefaan
    MEDICAL PHYSICS, 2015, 42 (11) : 6679 - 6689